Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T21:55:12.666Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-03-23T06:59:16",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-29077",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-29077",
    "datePublished": "2021-03-23T06:59:16",
    "dateReserved": "2021-03-23T00:00:00",
    "dateUpdated": "2024-08-03T21:55:12.666Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.6.2.2\", \"matchCriteriaId\": \"D8EF8E22-9DC7-4A42-99E0-A6822F647DF7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FEA73D22-970D-45F2-81F3-9576C04CCC94\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.6.2.4\", \"matchCriteriaId\": \"1CA086E1-DB23-4130-B746-D56F5A188C3B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F0D05F28-47A2-46AE-992E-132B34F6194B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.17.12\", \"matchCriteriaId\": \"845C1FCC-F54B-452A-B121-1CD1A7867027\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"14F257FE-31CE-4F74-829D-29407D74ADF7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.17.12\", \"matchCriteriaId\": \"64DF0B69-B591-47B6-88C1-82544AA3DE9B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4479CEAD-3B87-4993-80C8-1AE59242CFA4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.17.12\", \"matchCriteriaId\": \"106863FF-9BE9-4C18-9A86-C458FF9EBDD6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"01D12702-8B86-419C-8636-1259FD2D5844\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.17.12\", \"matchCriteriaId\": \"01E0EF50-145F-407A-8915-4EFFCD833505\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D92E4C8E-222A-476C-8273-F7171FC61F0B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.17.12\", \"matchCriteriaId\": \"0DC5A075-0619-409C-B057-41015B8C54B3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"221CA950-E984-44CD-9E1B-3AADE3CEBE52\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.17.12\", \"matchCriteriaId\": \"D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A45832BD-114D-42F1-B9F1-7532496D30A6\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.17.12\", \"matchCriteriaId\": \"E1723D5F-FFDB-4E4D-80B7-4B28598D5895\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"56AE9F2F-50F1-4917-BB21-FAEE6AACB14E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.17.12\", \"matchCriteriaId\": \"0D041B9F-37E4-48A9-9841-85EFFF7FA1D1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"192647CA-5BFC-4021-A91D-7CB8761FA137\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.17.12\", \"matchCriteriaId\": \"E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F8BF464E-63DB-4AC4-9B5D-E3ECDC000305\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.17.12\", \"matchCriteriaId\": \"B6AE1767-9D9A-4E9E-B088-6727FACFDE5C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C13F5C69-FA9B-472A-9036-0C2967BDCDE9\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.2.17.12\", \"matchCriteriaId\": \"F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B529194C-C440-4BC3-850F-0613FC548F86\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12.\"}, {\"lang\": \"es\", \"value\": \"Determinados dispositivos NETGEAR est\\u00e1n afectados por una inyecci\\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBS40V versiones anteriores a 2.6.2.4, RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3. 2.17.12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12\"}]",
      "id": "CVE-2021-29077",
      "lastModified": "2024-11-21T06:00:39.877",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"cve@mitre.org\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 9.6, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 6.0}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 9.6, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 6.0}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:A/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 5.8, \"accessVector\": \"ADJACENT_NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 6.5, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-03-23T07:15:14.013",
      "references": "[{\"url\": \"https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-77\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-29077\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-03-23T07:15:14.013\",\"lastModified\":\"2024-11-21T06:00:39.877\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12.\"},{\"lang\":\"es\",\"value\":\"Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBS40V versiones anteriores a 2.6.2.4, RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3. 2.17.12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.6,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.6,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":5.8,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.5,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.2.2\",\"matchCriteriaId\":\"D8EF8E22-9DC7-4A42-99E0-A6822F647DF7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FEA73D22-970D-45F2-81F3-9576C04CCC94\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.2.4\",\"matchCriteriaId\":\"1CA086E1-DB23-4130-B746-D56F5A188C3B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F0D05F28-47A2-46AE-992E-132B34F6194B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.17.12\",\"matchCriteriaId\":\"845C1FCC-F54B-452A-B121-1CD1A7867027\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"14F257FE-31CE-4F74-829D-29407D74ADF7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.17.12\",\"matchCriteriaId\":\"64DF0B69-B591-47B6-88C1-82544AA3DE9B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4479CEAD-3B87-4993-80C8-1AE59242CFA4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.17.12\",\"matchCriteriaId\":\"106863FF-9BE9-4C18-9A86-C458FF9EBDD6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"01D12702-8B86-419C-8636-1259FD2D5844\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.17.12\",\"matchCriteriaId\":\"01E0EF50-145F-407A-8915-4EFFCD833505\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D92E4C8E-222A-476C-8273-F7171FC61F0B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.17.12\",\"matchCriteriaId\":\"0DC5A075-0619-409C-B057-41015B8C54B3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"221CA950-E984-44CD-9E1B-3AADE3CEBE52\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.17.12\",\"matchCriteriaId\":\"D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A45832BD-114D-42F1-B9F1-7532496D30A6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.17.12\",\"matchCriteriaId\":\"E1723D5F-FFDB-4E4D-80B7-4B28598D5895\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"56AE9F2F-50F1-4917-BB21-FAEE6AACB14E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.17.12\",\"matchCriteriaId\":\"0D041B9F-37E4-48A9-9841-85EFFF7FA1D1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"192647CA-5BFC-4021-A91D-7CB8761FA137\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.17.12\",\"matchCriteriaId\":\"E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F8BF464E-63DB-4AC4-9B5D-E3ECDC000305\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.17.12\",\"matchCriteriaId\":\"B6AE1767-9D9A-4E9E-B088-6727FACFDE5C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C13F5C69-FA9B-472A-9036-0C2967BDCDE9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2.17.12\",\"matchCriteriaId\":\"F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B529194C-C440-4BC3-850F-0613FC548F86\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.