CVE-2021-31576 (GCVE-0-2021-31576)
Vulnerability from cvelistv5 – Published: 2023-02-06 00:00 – Updated: 2024-08-03 23:03
VLAI?
Summary
In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.
Severity ?
No CVSS data available.
CWE
- Elevation of Privilege
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MediaTek, Inc. | EN7528, EN7580 |
Affected:
Linux SDK versions less than TLM7.3.275.0-64
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:03:33.568Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://corp.mediatek.com/product-security-acknowledgements"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EN7528, EN7580",
"vendor": "MediaTek, Inc.",
"versions": [
{
"status": "affected",
"version": "Linux SDK versions less than TLM7.3.275.0-64"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Elevation of Privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-06T00:00:00",
"orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
"shortName": "MediaTek"
},
"references": [
{
"url": "https://corp.mediatek.com/product-security-acknowledgements"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
"assignerShortName": "MediaTek",
"cveId": "CVE-2021-31576",
"datePublished": "2023-02-06T00:00:00",
"dateReserved": "2021-04-22T00:00:00",
"dateUpdated": "2024-08-03T23:03:33.568Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:mediatek:en7580_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"tlm7.3.275.0-64\", \"matchCriteriaId\": \"AFFE9B98-0C16-4EBF-AE99-8163F19FD28C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:mediatek:en7580:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"061DBB68-80AF-4016-AAE0-EE9DFDFB341B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:mediatek:en7528_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"tlm7.3.275.0-64\", \"matchCriteriaId\": \"D77F5BED-66A1-48F5-B662-A187C1D89E99\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:mediatek:en7528:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CD990C82-4C61-479B-A49F-11A3C0812AC5\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.\"}, {\"lang\": \"es\", \"value\": \"En Boa existe una posible divulgaci\\u00f3n de informaci\\u00f3n debido a que falta una verificaci\\u00f3n de permiso. Esto podr\\u00eda dar lugar a la divulgaci\\u00f3n remota de informaci\\u00f3n a un atacante pr\\u00f3ximo sin necesidad de privilegios de ejecuci\\u00f3n adicionales. La interacci\\u00f3n del usuario no es necesaria para la explotaci\\u00f3n. ID de parche: A20210008; ID del problema: OSBNB00123241.\"}]",
"id": "CVE-2021-31576",
"lastModified": "2024-11-21T06:05:56.220",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
"published": "2023-02-06T22:15:09.370",
"references": "[{\"url\": \"https://corp.mediatek.com/product-security-acknowledgements\", \"source\": \"security@mediatek.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://corp.mediatek.com/product-security-acknowledgements\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "security@mediatek.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-862\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-31576\",\"sourceIdentifier\":\"security@mediatek.com\",\"published\":\"2023-02-06T22:15:09.370\",\"lastModified\":\"2024-11-21T06:05:56.220\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.\"},{\"lang\":\"es\",\"value\":\"En Boa existe una posible divulgaci\u00f3n de informaci\u00f3n debido a que falta una verificaci\u00f3n de permiso. Esto podr\u00eda dar lugar a la divulgaci\u00f3n remota de informaci\u00f3n a un atacante pr\u00f3ximo sin necesidad de privilegios de ejecuci\u00f3n adicionales. La interacci\u00f3n del usuario no es necesaria para la explotaci\u00f3n. ID de parche: A20210008; ID del problema: OSBNB00123241.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-862\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mediatek:en7580_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"tlm7.3.275.0-64\",\"matchCriteriaId\":\"AFFE9B98-0C16-4EBF-AE99-8163F19FD28C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mediatek:en7580:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"061DBB68-80AF-4016-AAE0-EE9DFDFB341B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mediatek:en7528_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"tlm7.3.275.0-64\",\"matchCriteriaId\":\"D77F5BED-66A1-48F5-B662-A187C1D89E99\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mediatek:en7528:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CD990C82-4C61-479B-A49F-11A3C0812AC5\"}]}]}],\"references\":[{\"url\":\"https://corp.mediatek.com/product-security-acknowledgements\",\"source\":\"security@mediatek.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://corp.mediatek.com/product-security-acknowledgements\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…