CVE-2021-31576 (GCVE-0-2021-31576)

Vulnerability from cvelistv5 – Published: 2023-02-06 00:00 – Updated: 2024-08-03 23:03
VLAI?
Summary
In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.
Severity ?
No CVSS data available.
CWE
  • Elevation of Privilege
Assigner
Impacted products
Vendor Product Version
MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-64
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:03:33.568Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://corp.mediatek.com/product-security-acknowledgements"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EN7528, EN7580",
          "vendor": "MediaTek, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "Linux SDK versions less than TLM7.3.275.0-64"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Elevation of Privilege",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-06T00:00:00",
        "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "shortName": "MediaTek"
      },
      "references": [
        {
          "url": "https://corp.mediatek.com/product-security-acknowledgements"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
    "assignerShortName": "MediaTek",
    "cveId": "CVE-2021-31576",
    "datePublished": "2023-02-06T00:00:00",
    "dateReserved": "2021-04-22T00:00:00",
    "dateUpdated": "2024-08-03T23:03:33.568Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:mediatek:en7580_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"tlm7.3.275.0-64\", \"matchCriteriaId\": \"AFFE9B98-0C16-4EBF-AE99-8163F19FD28C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:mediatek:en7580:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"061DBB68-80AF-4016-AAE0-EE9DFDFB341B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:mediatek:en7528_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"tlm7.3.275.0-64\", \"matchCriteriaId\": \"D77F5BED-66A1-48F5-B662-A187C1D89E99\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:mediatek:en7528:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CD990C82-4C61-479B-A49F-11A3C0812AC5\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.\"}, {\"lang\": \"es\", \"value\": \"En Boa existe una posible divulgaci\\u00f3n de informaci\\u00f3n debido a que falta una verificaci\\u00f3n de permiso. Esto podr\\u00eda dar lugar a la divulgaci\\u00f3n remota de informaci\\u00f3n a un atacante pr\\u00f3ximo sin necesidad de privilegios de ejecuci\\u00f3n adicionales. La interacci\\u00f3n del usuario no es necesaria para la explotaci\\u00f3n. ID de parche: A20210008; ID del problema: OSBNB00123241.\"}]",
      "id": "CVE-2021-31576",
      "lastModified": "2024-11-21T06:05:56.220",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
      "published": "2023-02-06T22:15:09.370",
      "references": "[{\"url\": \"https://corp.mediatek.com/product-security-acknowledgements\", \"source\": \"security@mediatek.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://corp.mediatek.com/product-security-acknowledgements\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "security@mediatek.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-862\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-31576\",\"sourceIdentifier\":\"security@mediatek.com\",\"published\":\"2023-02-06T22:15:09.370\",\"lastModified\":\"2024-11-21T06:05:56.220\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.\"},{\"lang\":\"es\",\"value\":\"En Boa existe una posible divulgaci\u00f3n de informaci\u00f3n debido a que falta una verificaci\u00f3n de permiso. Esto podr\u00eda dar lugar a la divulgaci\u00f3n remota de informaci\u00f3n a un atacante pr\u00f3ximo sin necesidad de privilegios de ejecuci\u00f3n adicionales. La interacci\u00f3n del usuario no es necesaria para la explotaci\u00f3n. ID de parche: A20210008; ID del problema: OSBNB00123241.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-862\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mediatek:en7580_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"tlm7.3.275.0-64\",\"matchCriteriaId\":\"AFFE9B98-0C16-4EBF-AE99-8163F19FD28C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mediatek:en7580:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"061DBB68-80AF-4016-AAE0-EE9DFDFB341B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mediatek:en7528_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"tlm7.3.275.0-64\",\"matchCriteriaId\":\"D77F5BED-66A1-48F5-B662-A187C1D89E99\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mediatek:en7528:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CD990C82-4C61-479B-A49F-11A3C0812AC5\"}]}]}],\"references\":[{\"url\":\"https://corp.mediatek.com/product-security-acknowledgements\",\"source\":\"security@mediatek.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://corp.mediatek.com/product-security-acknowledgements\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…