CVE-2021-37177 (GCVE-0-2021-37177)

Vulnerability from cvelistv5 – Published: 2021-09-14 10:47 – Updated: 2025-04-23 19:28
VLAI?
Summary
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The status provided by the syslog clients managed by the affected software can be manipulated by an unauthenticated attacker in the same network of the affected system.
CWE
  • CWE-471 - Modification of Assumed-Immutable Data (MAID)
Assigner
References
Impacted products
Vendor Product Version
Siemens SINEMA Remote Connect Server Affected: All versions < V3.0 SP2
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:04.039Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2021-37177",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-23T13:22:13.815715Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-23T19:28:31.544Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SINEMA Remote Connect Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0 SP2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.0 SP2). The status provided by the syslog clients managed by the affected software can be manipulated by an unauthenticated attacker in the same network of the affected system."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-471",
              "description": "CWE-471: Modification of Assumed-Immutable Data (MAID)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-14T10:47:45.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-37177",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SINEMA Remote Connect Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.0 SP2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.0 SP2). The status provided by the syslog clients managed by the affected software can be manipulated by an unauthenticated attacker in the same network of the affected system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-471: Modification of Assumed-Immutable Data (MAID)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37177",
    "datePublished": "2021-09-14T10:47:45.000Z",
    "dateReserved": "2021-07-21T00:00:00.000Z",
    "dateUpdated": "2025-04-23T19:28:31.544Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.0\", \"matchCriteriaId\": \"F65F9901-F4BD-4484-9749-D5022245D686\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"4F03BAD5-7B90-4212-ACBC-3C878C02CDAA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:sp1:*:*:*:*:*:*\", \"matchCriteriaId\": \"E5BACE03-50A7-4279-8CA5-2BB95224D485\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.0 SP2). The status provided by the syslog clients managed by the affected software can be manipulated by an unauthenticated attacker in the same network of the affected system.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V3.0 SP2). El estado proporcionado por los clientes syslog administrados por el software afectado puede ser manipulado por un atacante no autenticado en la misma red del sistema afectado\"}]",
      "id": "CVE-2021-37177",
      "lastModified": "2024-11-21T06:14:47.973",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:A/AC:L/Au:N/C:N/I:P/A:N\", \"baseScore\": 3.3, \"accessVector\": \"ADJACENT_NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 6.5, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-09-14T11:15:25.540",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-471\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-37177\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-09-14T11:15:25.540\",\"lastModified\":\"2025-04-23T20:15:29.400\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.0 SP2). The status provided by the syslog clients managed by the affected software can be manipulated by an unauthenticated attacker in the same network of the affected system.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V3.0 SP2). El estado proporcionado por los clientes syslog administrados por el software afectado puede ser manipulado por un atacante no autenticado en la misma red del sistema afectado\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:N/C:N/I:P/A:N\",\"baseScore\":3.3,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.5,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-471\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.0\",\"matchCriteriaId\":\"F65F9901-F4BD-4484-9749-D5022245D686\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4F03BAD5-7B90-4212-ACBC-3C878C02CDAA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"E5BACE03-50A7-4279-8CA5-2BB95224D485\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…