GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2021-38432 (GCVE-0-2021-38432)

Vulnerability from cvelistv5 – Published: 2021-10-15 14:13 – Updated: 2024-09-16 18:54
VLAI
Title
FATEK Automation Communication Server
Summary
FATEK Automation Communication Server Versions 1.13 and prior lacks proper validation of user-supplied data, which could result in a stack-based buffer overflow condition and allow an attacker to remotely execute code.
CWE
  • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
References
Impacted products
Vendor Product Version CPE status
FATEK Automation Communication Server Affected: All , ≤ 1.13 (custom)
guessed Create a notification for this product.
Date Public
2021-10-07 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.258Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-07"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Communication Server",
          "vendor": "FATEK Automation",
          "versions": [
            {
              "lessThanOrEqual": "1.13",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Natnael Samson (@NattiSamson), working with Trend Micro\u2019s Zero Day Initiative, reported this vulnerability to CISA."
        }
      ],
      "datePublic": "2021-10-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "FATEK Automation Communication Server Versions 1.13 and prior lacks proper validation of user-supplied data, which could result in a stack-based buffer overflow condition and allow an attacker to remotely execute code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-10-15T14:13:54.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-07"
        }
      ],
      "source": {
        "advisory": "ICSA_21-280-07",
        "discovery": "UNKNOWN"
      },
      "title": "FATEK Automation Communication Server",
      "workarounds": [
        {
          "lang": "en",
          "value": "FATEK Automation has not responded to requests to work with CISA to mitigate this vulnerability. Users of these affected products are invited to contact FATEK customer support for additional information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2021-10-07T17:54:00.000Z",
          "ID": "CVE-2021-38432",
          "STATE": "PUBLIC",
          "TITLE": "FATEK Automation Communication Server"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Communication Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.13"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "FATEK Automation"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Natnael Samson (@NattiSamson), working with Trend Micro\u2019s Zero Day Initiative, reported this vulnerability to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "FATEK Automation Communication Server Versions 1.13 and prior lacks proper validation of user-supplied data, which could result in a stack-based buffer overflow condition and allow an attacker to remotely execute code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-07",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-07"
            }
          ]
        },
        "source": {
          "advisory": "ICSA_21-280-07",
          "discovery": "UNKNOWN"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "FATEK Automation has not responded to requests to work with CISA to mitigate this vulnerability. Users of these affected products are invited to contact FATEK customer support for additional information."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38432",
    "datePublished": "2021-10-15T14:13:54.937Z",
    "dateReserved": "2021-08-10T00:00:00.000Z",
    "dateUpdated": "2024-09-16T18:54:26.198Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-38432",
      "date": "2026-09-16",
      "epss": "0.0187",
      "percentile": "0.78284"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fatek:communication_server_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.13\", \"matchCriteriaId\": \"90E03045-6F2B-405C-AB12-1A02024EEE42\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fatek:communication_server:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DBE74ACD-F778-4FD2-A340-A25A046F4C4A\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"FATEK Automation Communication Server Versions 1.13 and prior lacks proper validation of user-supplied data, which could result in a stack-based buffer overflow condition and allow an attacker to remotely execute code.\"}, {\"lang\": \"es\", \"value\": \"FATEK Automation Communication Server versiones anteriores a 1.13, no comprueban correctamente los datos suministrados por el usuario, que podr\\u00eda resultar en una condici\\u00f3n de desbordamiento del b\\u00fafer en la regi\\u00f3n stack de la memoria y permitir a un atacante ejecutar c\\u00f3digo de forma remota\"}]",
      "id": "CVE-2021-38432",
      "lastModified": "2024-11-21T06:17:05.177",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-10-15T15:15:08.390",
      "references": "[{\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-280-07\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-280-07\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-121\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-38432\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2021-10-15T15:15:08.390\",\"lastModified\":\"2024-11-21T06:17:05.177\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"FATEK Automation Communication Server Versions 1.13 and prior lacks proper validation of user-supplied data, which could result in a stack-based buffer overflow condition and allow an attacker to remotely execute code.\"},{\"lang\":\"es\",\"value\":\"FATEK Automation Communication Server versiones anteriores a 1.13, no comprueban correctamente los datos suministrados por el usuario, que podr\u00eda resultar en una condici\u00f3n de desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria y permitir a un atacante ejecutar c\u00f3digo de forma remota\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fatek:communication_server_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.13\",\"matchCriteriaId\":\"90E03045-6F2B-405C-AB12-1A02024EEE42\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fatek:communication_server:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DBE74ACD-F778-4FD2-A340-A25A046F4C4A\"}]}]}],\"references\":[{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-280-07\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-280-07\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}",
    "redhat_vex": {
      "current_release_date": "2026-03-27T13:42:41+00:00",
      "cve": "CVE-2021-38432",
      "id": "CVE-2021-38432",
      "initial_release_date": "2021-10-07T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "FATEK Automation Communication Server",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-38432.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…