CVE-2022-0815 (GCVE-0-2022-0815)
Vulnerability from cvelistv5 – Published: 2022-03-10 22:30 – Updated: 2024-08-02 23:40
VLAI?
Title
McAfee WebAdvisor - Extension Fingerprinting vulnerability
Summary
Improper access control vulnerability in McAfee WebAdvisor Chrome and Edge browser extensions up to 8.1.0.1895 allows a remote attacker to gain access to McAfee WebAdvisor settings and other details about the user’s system. This could lead to unexpected behaviors including; settings being changed, fingerprinting of the system leading to targeted scams, and not triggering the malicious software if McAfee software is detected.
Severity ?
6.5 (Medium)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| McAfee | McAfee WebAdvisor |
Affected:
unspecified , ≤ 8.1.0.1895
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T23:40:04.354Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "McAfee WebAdvisor",
"vendor": "McAfee",
"versions": [
{
"lessThanOrEqual": "8.1.0.1895",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control vulnerability in McAfee WebAdvisor Chrome and Edge browser extensions up to 8.1.0.1895 allows a remote attacker to gain access to McAfee WebAdvisor settings and other details about the user\u2019s system. This could lead to unexpected behaviors including; settings being changed, fingerprinting of the system leading to targeted scams, and not triggering the malicious software if McAfee software is detected."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668: Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-10T22:30:11",
"orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
"shortName": "trellix"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view"
}
],
"source": {
"advisory": "TS103273",
"discovery": "EXTERNAL"
},
"title": "McAfee WebAdvisor - Extension Fingerprinting vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@mcafee.com",
"ID": "CVE-2022-0815",
"STATE": "PUBLIC",
"TITLE": "McAfee WebAdvisor - Extension Fingerprinting vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "McAfee WebAdvisor",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "8.1.0.1895"
}
]
}
}
]
},
"vendor_name": "McAfee"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper access control vulnerability in McAfee WebAdvisor Chrome and Edge browser extensions up to 8.1.0.1895 allows a remote attacker to gain access to McAfee WebAdvisor settings and other details about the user\u2019s system. This could lead to unexpected behaviors including; settings being changed, fingerprinting of the system leading to targeted scams, and not triggering the malicious software if McAfee software is detected."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-668: Exposure of Resource to Wrong Sphere"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view",
"refsource": "MISC",
"url": "https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view"
}
]
},
"source": {
"advisory": "TS103273",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
"assignerShortName": "trellix",
"cveId": "CVE-2022-0815",
"datePublished": "2022-03-10T22:30:11",
"dateReserved": "2022-03-01T00:00:00",
"dateUpdated": "2024-08-02T23:40:04.354Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mcafee:webadvisor:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"8.1.0.1895\", \"matchCriteriaId\": \"3E91D9FD-4237-4EB5-ABE9-DA9A9FC2F4C3\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Improper access control vulnerability in McAfee WebAdvisor Chrome and Edge browser extensions up to 8.1.0.1895 allows a remote attacker to gain access to McAfee WebAdvisor settings and other details about the user\\u2019s system. This could lead to unexpected behaviors including; settings being changed, fingerprinting of the system leading to targeted scams, and not triggering the malicious software if McAfee software is detected.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad de control de acceso inapropiada en las extensiones del navegador McAfee WebAdvisor Chrome y Edge versiones hasta 8.1.0.1895, permite a un atacante remoto acceder a la configuraci\\u00f3n de McAfee WebAdvisor y a otros detalles del sistema del usuario. Esto podr\\u00eda conllevar a comportamientos no esperados, como el cambio de la configuraci\\u00f3n, la toma de huellas dactilares del sistema, conllevando a una realizaci\\u00f3n de estafas selectivas, y no desencadenando el software malicioso si es detectado el software de McAfee\"}]",
"id": "CVE-2022-0815",
"lastModified": "2024-11-21T06:39:27.250",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"trellixpsirt@trellix.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 2.5}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.4}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-03-10T23:15:08.500",
"references": "[{\"url\": \"https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view\", \"source\": \"trellixpsirt@trellix.com\"}, {\"url\": \"https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "trellixpsirt@trellix.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"trellixpsirt@trellix.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-668\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-668\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-0815\",\"sourceIdentifier\":\"trellixpsirt@trellix.com\",\"published\":\"2022-03-10T23:15:08.500\",\"lastModified\":\"2024-11-21T06:39:27.250\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper access control vulnerability in McAfee WebAdvisor Chrome and Edge browser extensions up to 8.1.0.1895 allows a remote attacker to gain access to McAfee WebAdvisor settings and other details about the user\u2019s system. This could lead to unexpected behaviors including; settings being changed, fingerprinting of the system leading to targeted scams, and not triggering the malicious software if McAfee software is detected.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de control de acceso inapropiada en las extensiones del navegador McAfee WebAdvisor Chrome y Edge versiones hasta 8.1.0.1895, permite a un atacante remoto acceder a la configuraci\u00f3n de McAfee WebAdvisor y a otros detalles del sistema del usuario. Esto podr\u00eda conllevar a comportamientos no esperados, como el cambio de la configuraci\u00f3n, la toma de huellas dactilares del sistema, conllevando a una realizaci\u00f3n de estafas selectivas, y no desencadenando el software malicioso si es detectado el software de McAfee\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"trellixpsirt@trellix.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":2.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"trellixpsirt@trellix.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-668\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-668\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mcafee:webadvisor:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"8.1.0.1895\",\"matchCriteriaId\":\"3E91D9FD-4237-4EB5-ABE9-DA9A9FC2F4C3\"}]}]}],\"references\":[{\"url\":\"https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view\",\"source\":\"trellixpsirt@trellix.com\"},{\"url\":\"https://service.mcafee.com/?articleId=TS103273\u0026page=shell\u0026shell=article-view\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…