cve-2022-23937
Vulnerability from cvelistv5
Published
2022-03-29 01:21
Modified
2024-08-03 03:59
Severity ?
EPSS score ?
Summary
In Wind River VxWorks 6.9 and 7, a specific crafted packet may lead to an out-of-bounds read during an IKE initial exchange scenario.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://support2.windriver.com/index.php?page=cve&pg=21#list | Vendor Advisory | |
cve@mitre.org | https://support2.windriver.com/index.php?page=security-notices | Vendor Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:59:23.097Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026pg=21#list" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In Wind River VxWorks 6.9 and 7, a specific crafted packet may lead to an out-of-bounds read during an IKE initial exchange scenario." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:L/C:N/I:N/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-29T01:21:06", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026pg=21#list" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-23937", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Wind River VxWorks 6.9 and 7, a specific crafted packet may lead to an out-of-bounds read during an IKE initial exchange scenario." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:L/C:N/I:N/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://support2.windriver.com/index.php?page=security-notices", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "name": "https://support2.windriver.com/index.php?page=cve\u0026pg=21#list", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=cve\u0026pg=21#list" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-23937", "datePublished": "2022-03-29T01:21:06", "dateReserved": "2022-01-25T00:00:00", "dateUpdated": "2024-08-03T03:59:23.097Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-23937\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-03-29T02:15:07.187\",\"lastModified\":\"2022-04-05T20:10:08.967\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Wind River VxWorks 6.9 and 7, a specific crafted packet may lead to an out-of-bounds read during an IKE initial exchange scenario.\"},{\"lang\":\"es\",\"value\":\"En Wind River VxWorks versiones 6.9 y 7, un paquete dise\u00f1ado espec\u00edfico puede provocar una lectura fuera de l\u00edmites durante un escenario de intercambio inicial de IKE\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:6.9:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"01004955-97D1-4F7E-80D4-4B1509945FBF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4810B35-06F6-4971-BE87-A30B1CF58AA0\"}]}]}],\"references\":[{\"url\":\"https://support2.windriver.com/index.php?page=cve\u0026pg=21#list\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://support2.windriver.com/index.php?page=security-notices\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
gsd-2022-23937
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
In Wind River VxWorks 6.9 and 7, a specific crafted packet may lead to an out-of-bounds read during an IKE initial exchange scenario.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-23937", "description": "In Wind River VxWorks 6.9 and 7, a specific crafted packet may lead to an out-of-bounds read during an IKE initial exchange scenario.", "id": "GSD-2022-23937" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-23937" ], "details": "In Wind River VxWorks 6.9 and 7, a specific crafted packet may lead to an out-of-bounds read during an IKE initial exchange scenario.", "id": "GSD-2022-23937", "modified": "2023-12-13T01:19:35.130312Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-23937", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Wind River VxWorks 6.9 and 7, a specific crafted packet may lead to an out-of-bounds read during an IKE initial exchange scenario." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:L/C:N/I:N/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://support2.windriver.com/index.php?page=security-notices", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "name": "https://support2.windriver.com/index.php?page=cve\u0026pg=21#list", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=cve\u0026pg=21#list" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:windriver:vxworks:6.9:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:windriver:vxworks:7.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-23937" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "In Wind River VxWorks 6.9 and 7, a specific crafted packet may lead to an out-of-bounds read during an IKE initial exchange scenario." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-125" } ] } ] }, "references": { "reference_data": [ { "name": "https://support2.windriver.com/index.php?page=security-notices", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "name": "https://support2.windriver.com/index.php?page=cve\u0026pg=21#list", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026pg=21#list" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2022-04-05T20:10Z", "publishedDate": "2022-03-29T02:15Z" } } }
ghsa-8cfm-6x5f-q2cf
Vulnerability from github
Published
2022-03-30 00:00
Modified
2022-04-06 00:02
Severity ?
Details
In Wind River VxWorks 6.9 and 7, a specific crafted packet may lead to an out-of-bounds read during an IKE initial exchange scenario.
{ "affected": [], "aliases": [ "CVE-2022-23937" ], "database_specific": { "cwe_ids": [ "CWE-125" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-03-29T02:15:00Z", "severity": "HIGH" }, "details": "In Wind River VxWorks 6.9 and 7, a specific crafted packet may lead to an out-of-bounds read during an IKE initial exchange scenario.", "id": "GHSA-8cfm-6x5f-q2cf", "modified": "2022-04-06T00:02:02Z", "published": "2022-03-30T00:00:30Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-23937" }, { "type": "WEB", "url": "https://support2.windriver.com/index.php?page=cve\u0026pg=21#list" }, { "type": "WEB", "url": "https://support2.windriver.com/index.php?page=security-notices" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "type": "CVSS_V3" } ] }
wid-sec-w-2023-2190
Vulnerability from csaf_certbund
Published
2022-03-28 22:00
Modified
2023-08-28 22:00
Summary
Wind River VxWorks: Schwachstelle ermöglicht Denial of Service
Notes
Das BSI ist als Anbieter für die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch dafür verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgfältig im Einzelfall zu prüfen.
Produktbeschreibung
VxWorks ist ein proprietäres Echtzeitbetriebssystem, das von Wind River Systems entwickelt wird.
Angriff
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in Wind River VxWorks ausnutzen, um einen Denial of Service Angriff durchzuführen.
Betroffene Betriebssysteme
- Sonstiges
{ "document": { "aggregate_severity": { "text": "mittel" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "VxWorks ist ein propriet\u00e4res Echtzeitbetriebssystem, das von Wind River Systems entwickelt wird.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein entfernter, anonymer Angreifer kann eine Schwachstelle in Wind River VxWorks ausnutzen, um einen Denial of Service Angriff durchzuf\u00fchren.", "title": "Angriff" }, { "category": "general", "text": "- Sonstiges", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-2190 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2022/wid-sec-w-2023-2190.json" }, { "category": "self", "summary": "WID-SEC-2023-2190 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-2190" }, { "category": "external", "summary": "Hitachi Energy Cybersecurity Advisory vom 2023-08-29", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000153-CSAF\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "category": "external", "summary": "National Vulnerability Database vom 2022-03-28", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-23937" } ], "source_lang": "en-US", "title": "Wind River VxWorks: Schwachstelle erm\u00f6glicht Denial of Service", "tracking": { "current_release_date": "2023-08-28T22:00:00.000+00:00", "generator": { "date": "2024-02-15T17:42:06.444+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2023-2190", "initial_release_date": "2022-03-28T22:00:00.000+00:00", "revision_history": [ { "date": "2022-03-28T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" }, { "date": "2023-08-28T22:00:00.000+00:00", "number": "2", "summary": "Neue Updates aufgenommen" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "Hitachi Energy RTU500", "product": { "name": "Hitachi Energy RTU500", "product_id": "T027844", "product_identification_helper": { "cpe": "cpe:/h:abb:rtu500:-" } } } ], "category": "vendor", "name": "Hitachi Energy" }, { "branches": [ { "branches": [ { "category": "product_name", "name": "Wind River VxWorks 6.9", "product": { "name": "Wind River VxWorks 6.9", "product_id": "464220", "product_identification_helper": { "cpe": "cpe:/o:windriver:vxworks:6.9" } } }, { "category": "product_name", "name": "Wind River VxWorks 7", "product": { "name": "Wind River VxWorks 7", "product_id": "T022452", "product_identification_helper": { "cpe": "cpe:/o:windriver:vxworks:7" } } } ], "category": "product_name", "name": "VxWorks" } ], "category": "vendor", "name": "Wind River" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-23937", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Wind River VxWorks. Der Fehler besteht aufgrund eines Out-of-bounds-Read w\u00e4hrend eines initialen IKE-Austauschs. Ein entfernter, anonymer Angreifer kann diese Schwachstelle ausnutzen, um einen Denial-of-Service-Zustand zu verursachen." } ], "product_status": { "known_affected": [ "464220", "T022452", "T027844" ] }, "release_date": "2022-03-28T22:00:00Z", "title": "CVE-2022-23937" } ] }
icsa-23-143-02
Vulnerability from csaf_cisa
Published
2023-05-05 06:00
Modified
2023-10-19 06:00
Summary
Hitachi Energy's RTU500 Series Product (UPDATE B)
Notes
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to crash the device being accessed or cause a denial-of-service condition.
Critical infrastructure sectors
Energy
Countries/areas deployed
Worldwide
Company headquarters location
Switzerland
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
{ "document": { "acknowledgments": [ { "organization": "Hitachi Energy", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to crash the device being accessed or cause a denial-of-service condition. ", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-23-143-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-143-02.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-23-143-02 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-143-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Hitachi Energy\u0027s RTU500 Series Product (UPDATE B)", "tracking": { "current_release_date": "2023-10-19T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-143-02", "initial_release_date": "2023-05-05T06:00:00.000000Z", "revision_history": [ { "date": "2023-05-05T06:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Initial Publication" }, { "date": "2023-09-28T06:00:00.000000Z", "legacy_version": "Update A", "number": "2", "summary": "Update A - Update to Mitigations and Affected Products" }, { "date": "2023-10-19T06:00:00.000000Z", "legacy_version": "Update B", "number": "3", "summary": "Update B - Update to Mitigations and Affected Products" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003e=12.0.1|\u003c=12.0.15", "product": { "name": "RTU500 series CMU Firmware: \u003e=12.0.1|\u003c=12.0.15", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=12.2.1|\u003c=12.2.12", "product": { "name": "RTU500 series CMU Firmware: \u003e=12.2.1|\u003c=12.2.12", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=12.4.1|\u003c=12.4.12", "product": { "name": "RTU500 series CMU Firmware: \u003e=12.4.1|\u003c=12.4.12", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=12.6.1|\u003c=12.6.9", "product": { "name": "RTU500 series CMU Firmware: \u003e=12.6.1|\u003c=12.6.9", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=12.7.1|\u003c=12.7.6", "product": { "name": "RTU500 series CMU Firmware: \u003e=12.7.1|\u003c=12.7.6", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=13.2.1|\u003c=13.2.6", "product": { "name": "RTU500 series CMU Firmware: \u003e=13.2.1|\u003c=13.2.6", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=13.3.1|\u003c=13.3.3", "product": { "name": "RTU500 series CMU Firmware: \u003e=13.3.1|\u003c=13.3.3", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=13.4.1|\u003c=13.4.2", "product": { "name": "RTU500 series CMU Firmware: \u003e=13.4.1|\u003c=13.4.2", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" } ], "category": "vendor", "name": "Hitachi Energy" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-0286", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "summary", "text": "There is a type-confusion vulnerability affecting X.400 address processing within an X.509 GeneralName. This vulnerability could allow an attacker to pass arbitrary pointers to a memcmp call, enabling access to read memory contents or cause a denial-of-service condition.X.400 addresses parsed as an ASN1_STRING while the public structure definition for GENERAL_NAME incorrectly specifies the x400Address field type as ASN1_TYPE.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-0286" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.0.1 - 12.0.14: Update to CMU Firmware version 12.0.15* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.2.1 - 12.2.11: Update to CMU Firmware version 12.2.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.4.1 - 12.4.11: Update to CMU Firmware version 12.4.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.6.1 - 12.6.8: Update to CMU Firmware version 12.6.9", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.7.1 - 12.7.5: Update to CMU Firmware version 12.7.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.2.1 - 13.2.5: Update to CMU Firmware version 13.2.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.3.1 - 13.3.3: Update to CMU Firmware version 13.3.4* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.4.1: Update to CMU Firmware version 13.4.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Until the updates are made available, Hitachi Energy recommends the following general mitigation factors/workarounds for the products with RTU500 series CMU Firmware versions 12.0.1 \ufffd 12.0.15, 12.2.1 \ufffd 12.2.12, 12.4.1 \ufffd 12.4.12, 12.6.1 \ufffd 12.6.9, 12.7.1 \ufffd 12.7.6, 13.2.1 \ufffd 13.2.6, 13.3.1 \ufffd 13.3.3, 13.4.2 to address the vulnerabilities CVE-2023-0286 and CVE-2022-4304:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Recommended security practices and firewall configurations can help protect a process control network from attacks originating from outside the network including.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Physically protect process control systems from direct access by unauthorized personnel.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Do not allow process control systems direct connections to the internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Separate process control systems from other networks by means of a firewall system that has a minimal number of ports exposed.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy\u0027s Security Advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "8DBD000150", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000150\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "category": "mitigation", "details": "8DBD000153", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000153\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] }, { "cve": "CVE-2022-4304", "cwe": { "id": "CWE-208", "name": "Observable Timing Discrepancy" }, "notes": [ { "category": "summary", "text": "A timing-based side channel exists in the OpenSSL RSA Decryption implementation. This could allow an attacker sufficient access to recover plaintext across a network to perform a Bleichenbacher style attack. The vulnerability affects all RSA padding modes: PKCS#1 v1.5, RSA-OEAP and RSASVE.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-4304" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.0.1 - 12.0.14: Update to CMU Firmware version 12.0.15* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.2.1 - 12.2.11: Update to CMU Firmware version 12.2.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.4.1 - 12.4.11: Update to CMU Firmware version 12.4.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.6.1 - 12.6.8: Update to CMU Firmware version 12.6.9", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.7.1 - 12.7.5: Update to CMU Firmware version 12.7.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.2.1 - 13.2.5: Update to CMU Firmware version 13.2.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.3.1 - 13.3.3: Update to CMU Firmware version 13.3.4* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.4.1: Update to CMU Firmware version 13.4.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "Until the updates are made available, Hitachi Energy recommends the following general mitigation factors/workarounds for the products with RTU500 series CMU Firmware versions 12.0.1 - 12.0.15, 12.2.1 - 12.2.12, 12.4.1 - 12.4.12, 12.6.1 - 12.6.9, 12.7.1 - 12.7.6, 13.2.1 - 13.2.6, 13.3.1 - 13.3.3, 13.4.2 to address the vulnerabilities CVE-2023-0286 and CVE-2022-4304:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Recommended security practices and firewall configurations can help protect a process control network from attacks originating from outside the network including.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Physically protect process control systems from direct access by unauthorized personnel.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Do not allow process control systems direct connections to the internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Separate process control systems from other networks by means of a firewall system that has a minimal number of ports exposed.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy\u0027s Security Advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "8DBD000150", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000150\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "category": "mitigation", "details": "8DBD000153", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000153\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] }, { "cve": "CVE-2022-23937", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the Wind River VxWorks version 6.9 affecting the RTU500 series product versions listed. An attacker could exploit the vulnerability by using a specific crafted packet that could lead to an out-of-bounds read during an IKE initial exchange scenario. ", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23937" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy has released the following mitigations/fixes for CVE-2022-23937, CVE-2022-0778, CVE-2021-3711, and CVE-2021-3712:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.0.1 \ufffd 12.0.14: Update to CMU Firmware version 12.0.15* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.2.1 \ufffd 12.2.11: Update to CMU Firmware version 12.2.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.4.1 \ufffd 12.4.11: Update to CMU Firmware version 12.4.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.6.1 \ufffd 12.6.8: Update to CMU Firmware version 12.6.9", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.7.1 \ufffd 12.7.5: Update to CMU Firmware version 12.7.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.2.1 \ufffd 13.2.5: Update to CMU Firmware version 13.2.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.3.1 \ufffd 13.3.3: Update to CMU Firmware version 13.3.4* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.4.1: Update to CMU Firmware version 13.4.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Recommended security practices and firewall configurations can help protect a process control network from attacks originating from outside the network including.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Physically protect process control systems from direct access by unauthorized personnel.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Do not allow process control systems direct connections to the internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Separate process control systems from other networks by means of a firewall system that has a minimal number of ports exposed.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy\u0027s Security Advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "8DBD000150", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000150\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "category": "mitigation", "details": "8DBD000153", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000153\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] }, { "cve": "CVE-2022-0778", "cwe": { "id": "CWE-835", "name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the OpenSSL version 1.0.2 that affects the RTU500 Series product versions listed. An attacker can exploit the BN_mod_sqrt() function to compute a modular square root that contains a bug causing a continual loop for non-prime moduli. ", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-0778" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy has released the following mitigations/fixes for CVE-2022-23937, CVE-2022-0778, CVE-2021-3711, and CVE-2021-3712:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.0.1 \ufffd 12.0.14: Update to CMU Firmware version 12.0.15* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.2.1 \ufffd 12.2.11: Update to CMU Firmware version 12.2.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.4.1 \ufffd 12.4.11: Update to CMU Firmware version 12.4.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.6.1 \ufffd 12.6.8: Update to CMU Firmware version 12.6.9", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.7.1 \ufffd 12.7.5: Update to CMU Firmware version 12.7.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.2.1 \ufffd 13.2.5: Update to CMU Firmware version 13.2.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.3.1 \ufffd 13.3.3: Update to CMU Firmware version 13.3.4* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.4.1: Update to CMU Firmware version 13.4.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Recommended security practices and firewall configurations can help protect a process control network from attacks originating from outside the network including.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Physically protect process control systems from direct access by unauthorized personnel.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Do not allow process control systems direct connections to the internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Separate process control systems from other networks by means of a firewall system that has a minimal number of ports exposed.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy\u0027s Security Advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "8DBD000150", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000150\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "category": "mitigation", "details": "8DBD000153", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000153\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] }, { "cve": "CVE-2021-3711", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the OpenSSL Version 1.0.2 affecting the RTU500 Series product versions listed. An attacker with access to applications and the capability to present SM2 content for decryption could cause a buffer overflow up to a maximum of 62 bytes while altering contents of data present after the buffer. This vulnerability could allow an attacker to change application behavior or cause the application to crash.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-3711" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy has released the following mitigations/fixes for CVE-2022-23937, CVE-2022-0778, CVE-2021-3711, and CVE-2021-3712:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.0.1 - 12.0.14: Update to CMU Firmware version 12.0.15* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.2.1 - 12.2.11: Update to CMU Firmware version 12.2.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.4.1 - 12.4.11: Update to CMU Firmware version 12.4.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.6.1 - 12.6.8: Update to CMU Firmware version 12.6.9", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.7.1 - 12.7.5: Update to CMU Firmware version 12.7.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.2.1 - 13.2.5: Update to CMU Firmware version 13.2.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.3.1 - 13.3.3: Update to CMU Firmware version 13.3.4* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.4.1: Update to CMU Firmware version 13.4.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Recommended security practices and firewall configurations can help protect a process control network from attacks originating from outside the network including.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Physically protect process control systems from direct access by unauthorized personnel.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Do not allow process control systems direct connections to the internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Separate process control systems from other networks by means of a firewall system that has a minimal number of ports exposed.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy\u0027s Security Advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "8DBD000150", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000150\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "category": "mitigation", "details": "8DBD000153", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000153\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] }, { "cve": "CVE-2021-3712", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the OpenSSL Version 1.0.2 affecting the RTU500 Series product versions listed. A malicious actor could cause an application to directly construct an ASN1_STRING and then process it through one of the affected OpenSSL functions. Exploiting this vulnerability could create a system crash causing a denial-of-service condition or a disclosure of private memory contents, such as private keys or sensitive plaintext. ", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-3712" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy has released the following mitigations/fixes for CVE-2022-23937, CVE-2022-0778, CVE-2021-3711, and CVE-2021-3712:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.0.1 - 12.0.14: Update to CMU Firmware version 12.0.15* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.2.1 - 12.2.11: Update to CMU Firmware version 12.2.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.4.1 - 12.4.11: Update to CMU Firmware version 12.4.12* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.6.1 - 12.6.8: Update to CMU Firmware version 12.6.9", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 12.7.1 - 12.7.5: Update to CMU Firmware version 12.7.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.2.1 - 13.2.5: Update to CMU Firmware version 13.2.6", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.3.1 - 13.3.3: Update to CMU Firmware version 13.3.4* (Planned Update)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware version 13.4.1: Update to CMU Firmware version 13.4.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Recommended security practices and firewall configurations can help protect a process control network from attacks originating from outside the network including.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Physically protect process control systems from direct access by unauthorized personnel.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Do not allow process control systems direct connections to the internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Separate process control systems from other networks by means of a firewall system that has a minimal number of ports exposed.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy\u0027s Security Advisories:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "8DBD000150", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000150\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "category": "mitigation", "details": "8DBD000153", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000153\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] } ] }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.