CVE-2022-24285 (GCVE-0-2022-24285)
Vulnerability from cvelistv5 – Published: 2022-03-08 22:45 – Updated: 2024-08-03 04:07
VLAI?
Summary
Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:07:02.336Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://community.acer.com/en/kb/articles/14761"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-08T22:45:37",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://community.acer.com/en/kb/articles/14761"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-24285",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://community.acer.com/en/kb/articles/14761",
"refsource": "MISC",
"url": "https://community.acer.com/en/kb/articles/14761"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-24285",
"datePublished": "2022-03-08T22:45:37",
"dateReserved": "2022-01-31T00:00:00",
"dateUpdated": "2024-08-03T04:07:02.336Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:acer:care_center:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"4.00.3000\", \"versionEndExcluding\": \"4.00.3042\", \"matchCriteriaId\": \"BAC32757-825B-437E-AD44-C2EE8D1E91AB\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.\"}, {\"lang\": \"es\", \"value\": \"Acer Care Center versiones 4.00.30xx anteriores a 4.00.3042 contienen una vulnerabilidad de escalada de privilegios local. El proceso de usuario es comunicado con un servicio de autoridad del sistema llamado ACCsvc mediante una tuber\\u00eda con nombre. En este caso, la tuber\\u00eda nombrada tambi\\u00e9n recibe derechos de lectura y escritura del usuario general. Adem\\u00e1s, el programa de servicio no verifica el usuario cuando es comunicado. Puede existir un hilo con un comando espec\\u00edfico. Cuando es enviada la ruta del programa a ejecutar, es producida una escalada de privilegios local en la que el programa de servicio ejecuta la ruta con privilegios del sistema\"}]",
"id": "CVE-2022-24285",
"lastModified": "2024-11-21T06:50:05.380",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-03-10T17:46:02.813",
"references": "[{\"url\": \"https://community.acer.com/en/kb/articles/14761\", \"source\": \"cve@mitre.org\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"https://community.acer.com/en/kb/articles/14761\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-287\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-24285\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-03-10T17:46:02.813\",\"lastModified\":\"2024-11-21T06:50:05.380\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.\"},{\"lang\":\"es\",\"value\":\"Acer Care Center versiones 4.00.30xx anteriores a 4.00.3042 contienen una vulnerabilidad de escalada de privilegios local. El proceso de usuario es comunicado con un servicio de autoridad del sistema llamado ACCsvc mediante una tuber\u00eda con nombre. En este caso, la tuber\u00eda nombrada tambi\u00e9n recibe derechos de lectura y escritura del usuario general. Adem\u00e1s, el programa de servicio no verifica el usuario cuando es comunicado. Puede existir un hilo con un comando espec\u00edfico. Cuando es enviada la ruta del programa a ejecutar, es producida una escalada de privilegios local en la que el programa de servicio ejecuta la ruta con privilegios del sistema\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:acer:care_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.00.3000\",\"versionEndExcluding\":\"4.00.3042\",\"matchCriteriaId\":\"BAC32757-825B-437E-AD44-C2EE8D1E91AB\"}]}]}],\"references\":[{\"url\":\"https://community.acer.com/en/kb/articles/14761\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://community.acer.com/en/kb/articles/14761\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…