cve-2022-25164
Vulnerability from cvelistv5
Published
2022-11-24 23:21
Modified
2024-08-03 04:36
Summary
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:36:05.086Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A to 1.095Z"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX OPC UA Module Configurator-R",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.08J and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module."
            }
          ],
          "value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-29T07:41:03.163Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-25164",
    "datePublished": "2022-11-24T23:21:25.536Z",
    "dateReserved": "2022-02-14T22:38:29.671Z",
    "dateUpdated": "2024-08-03T04:36:05.086Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-25164\",\"sourceIdentifier\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"published\":\"2022-11-25T00:15:09.907\",\"lastModified\":\"2023-06-29T08:15:10.023\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de almacenamiento de texto sin cifrar de informaci\u00f3n confidencial en Mitsubishi Electric GX Works3 versiones de 1.000A a 1.095Z y Mitsubishi Electric MX OPC UA Module Configurator-R versiones 1.08J y anteriores permite que un atacante remoto no autenticado revele informaci\u00f3n sensible. Como resultado, atacantes no autenticados pueden obtener acceso no autorizado al m\u00f3dulo de CPU de MELSEC y al m\u00f3dulo de servidor OPC UA de MELSEC.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":8.6,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":4.0}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]},{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.000a\",\"versionEndIncluding\":\"1.011m\",\"matchCriteriaId\":\"A868567B-2BAA-45AE-AEC9-3AFEF2361297\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.015r\",\"versionEndIncluding\":\"1.086q\",\"matchCriteriaId\":\"56BD062B-0D41-42E2-B9EF-B7FBB514CFF9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.087r\",\"matchCriteriaId\":\"C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:mx_opc_ua_module_configurator-r:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"259C29BF-D845-42E4-8289-BD2FDBE77133\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/vu/JVNVU97244961/index.html\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\"},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.