CVE-2022-25164 (GCVE-0-2022-25164)
Vulnerability from cvelistv5 – Published: 2022-11-24 23:21 – Updated: 2025-04-25 17:52
VLAI?
Summary
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.
Severity ?
8.6 (High)
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric Corporation | GX Works3 |
Affected:
from 1.000A to 1.095Z
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:36:05.086Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU97244961/index.html"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-25164",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-25T17:52:39.668512Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-25T17:52:48.881Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GX Works3",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "from 1.000A to 1.095Z"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MX OPC UA Module Configurator-R",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.08J and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module."
}
],
"value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-29T07:41:03.163Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU97244961/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-25164",
"datePublished": "2022-11-24T23:21:25.536Z",
"dateReserved": "2022-02-14T22:38:29.671Z",
"dateUpdated": "2025-04-25T17:52:48.881Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.000a\", \"versionEndIncluding\": \"1.011m\", \"matchCriteriaId\": \"A868567B-2BAA-45AE-AEC9-3AFEF2361297\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.015r\", \"versionEndIncluding\": \"1.086q\", \"matchCriteriaId\": \"56BD062B-0D41-42E2-B9EF-B7FBB514CFF9\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.087r\", \"matchCriteriaId\": \"C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mitsubishielectric:mx_opc_ua_module_configurator-r:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"259C29BF-D845-42E4-8289-BD2FDBE77133\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.\"}, {\"lang\": \"es\", \"value\": \"Vulnerabilidad de almacenamiento de texto sin cifrar de informaci\\u00f3n confidencial en Mitsubishi Electric GX Works3 versiones de 1.000A a 1.095Z y Mitsubishi Electric MX OPC UA Module Configurator-R versiones 1.08J y anteriores permite que un atacante remoto no autenticado revele informaci\\u00f3n sensible. Como resultado, atacantes no autenticados pueden obtener acceso no autorizado al m\\u00f3dulo de CPU de MELSEC y al m\\u00f3dulo de servidor OPC UA de MELSEC.\"}]",
"id": "CVE-2022-25164",
"lastModified": "2024-11-21T06:51:43.907",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N\", \"baseScore\": 8.6, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 4.0}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
"published": "2022-11-25T00:15:09.907",
"references": "[{\"url\": \"https://jvn.jp/vu/JVNVU97244961/index.html\", \"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05\", \"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\"}, {\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf\", \"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU97244961/index.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-312\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-312\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-25164\",\"sourceIdentifier\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"published\":\"2022-11-25T00:15:09.907\",\"lastModified\":\"2024-11-21T06:51:43.907\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de almacenamiento de texto sin cifrar de informaci\u00f3n confidencial en Mitsubishi Electric GX Works3 versiones de 1.000A a 1.095Z y Mitsubishi Electric MX OPC UA Module Configurator-R versiones 1.08J y anteriores permite que un atacante remoto no autenticado revele informaci\u00f3n sensible. Como resultado, atacantes no autenticados pueden obtener acceso no autorizado al m\u00f3dulo de CPU de MELSEC y al m\u00f3dulo de servidor OPC UA de MELSEC.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N\",\"baseScore\":8.6,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":4.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.000a\",\"versionEndIncluding\":\"1.011m\",\"matchCriteriaId\":\"A868567B-2BAA-45AE-AEC9-3AFEF2361297\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.015r\",\"versionEndIncluding\":\"1.086q\",\"matchCriteriaId\":\"56BD062B-0D41-42E2-B9EF-B7FBB514CFF9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.087r\",\"matchCriteriaId\":\"C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:mx_opc_ua_module_configurator-r:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"259C29BF-D845-42E4-8289-BD2FDBE77133\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/vu/JVNVU97244961/index.html\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\"},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://jvn.jp/vu/JVNVU97244961/index.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU97244961/index.html\", \"tags\": [\"government-resource\", \"x_transferred\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05\", \"tags\": [\"government-resource\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T04:36:05.086Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-25164\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-25T17:52:39.668512Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-25T17:52:44.268Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.6, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GX Works3\", \"versions\": [{\"status\": \"affected\", \"version\": \"from 1.000A to 1.095Z\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MX OPC UA Module Configurator-R\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.08J and prior\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU97244961/index.html\", \"tags\": [\"government-resource\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05\", \"tags\": [\"government-resource\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-312\", \"description\": \"CWE-312 Cleartext Storage of Sensitive Information\"}]}], \"providerMetadata\": {\"orgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"shortName\": \"Mitsubishi\", \"dateUpdated\": \"2023-06-29T07:41:03.163Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-25164\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-25T17:52:48.881Z\", \"dateReserved\": \"2022-02-14T22:38:29.671Z\", \"assignerOrgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"datePublished\": \"2022-11-24T23:21:25.536Z\", \"requesterUserId\": \"520cc88b-a1c8-44f6-9154-21a4d74c769f\", \"assignerShortName\": \"Mitsubishi\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…