Summary
A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected conne ...
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:26:05.982Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "MicroSCADA X SYS600", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "10" }, { "status": "affected", "version": "10.1" }, { "status": "affected", "version": "10.1.1" }, { "status": "affected", "version": "10.2" }, { "status": "affected", "version": "10.2.1" }, { "status": "affected", "version": "10.3" }, { "status": "affected", "version": "10.3.1" } ] }, { "product": "MicroSCADA Pro SYS600", "vendor": "Hitachi Energy", "versions": [ { "lessThanOrEqual": "9.2 FP2 Hotfix 4", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2022-09-06T00:00:00", "descriptions": [ { "lang": "en", "value": "Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-09-14T17:07:31", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "solutions": [ { "lang": "en", "value": "Remediated in SYS600 10.4 \nFor MicroSCADA Pro SYS600 - Upgrade to at least SYS600 version 10.4.\nFor MicroSCADA X SYS600 - Update to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "title": "A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected conne ...", "workarounds": [ { "lang": "en", "value": "Apply general mitigation factors as specify in the advisory." } ], "x_ConverterErrors": { "TITLE": { "error": "TITLE too long. Truncating in v5 record.", "message": "Truncated!" } }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "DATE_PUBLIC": "2022-09-06T14:30:00.000Z", "ID": "CVE-2022-29492", "STATE": "PUBLIC", "TITLE": "A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MicroSCADA X SYS600", "version": { "version_data": [ { "version_affected": "=", "version_value": "10" }, { "version_affected": "=", "version_value": "10.1" }, { "version_affected": "=", "version_value": "10.1.1" }, { "version_affected": "=", "version_value": "10.2" }, { "version_affected": "=", "version_value": "10.2.1" }, { "version_affected": "=", "version_value": "10.3" }, { "version_affected": "=", "version_value": "10.3.1" } ] } }, { "product_name": "MicroSCADA Pro SYS600", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "9.2 FP2 Hotfix 4" } ] } } ] }, "vendor_name": "Hitachi Energy" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "solution": [ { "lang": "en", "value": "Remediated in SYS600 10.4 \nFor MicroSCADA Pro SYS600 - Upgrade to at least SYS600 version 10.4.\nFor MicroSCADA X SYS600 - Update to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "value": "Apply general mitigation factors as specify in the advisory." } ] } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2022-29492", "datePublished": "2022-09-14T17:07:31.147316Z", "dateReserved": "2022-04-29T00:00:00", "dateUpdated": "2024-09-17T00:57:03.194Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-29492\",\"sourceIdentifier\":\"cybersecurity@hitachienergy.com\",\"published\":\"2022-09-14T18:15:10.117\",\"lastModified\":\"2022-10-05T13:45:56.650\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de comprobaci\u00f3n de entrada inapropiada en el manejo de un paquete TCP IEC 104 malformado en Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Al recibir un paquete TCP IEC 104 malformado, el paquete malformado es descartado, pero la conexi\u00f3n TCP es dejada abierta. Esto puede causar una denegaci\u00f3n de servicio si la conexi\u00f3n afectada es dejada abierta. Este problema afecta a: Hitachi Energy MicroSCADA Pro SYS600 versi\u00f3n 9.4 FP2 Hotfix 4 y versiones anteriores Hitachi Energy MicroSCADA X SYS600 versi\u00f3n 10 hasta 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_pro_sys600:9. 2:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_pro_sys600:9. 4:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10. 1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*:*\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.0\",\"versionEndExcluding\":\"10.4\",\"matchCriteriaId\":\"AD1BD113-3219-458A-82CC-2BCDF55B9A13\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"42B6499F-D82D-4B02-BBEC-60B36FB0C678\"}]}]}],\"references\":[{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@hitachienergy.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.