CVE-2022-31205 (GCVE-0-2022-31205)

Vulnerability from cvelistv5 – Published: 2022-07-26 21:28 – Updated: 2024-08-03 07:11
VLAI
Summary
In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication.
Severity
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:11:39.641Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.forescout.com/blog/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-26T21:28:41.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.forescout.com/blog/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-31205",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.forescout.com/blog/",
              "refsource": "MISC",
              "url": "https://www.forescout.com/blog/"
            },
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-31205",
    "datePublished": "2022-07-26T21:28:41.000Z",
    "dateReserved": "2022-05-18T00:00:00.000Z",
    "dateUpdated": "2024-08-03T07:11:39.641Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-31205",
      "date": "2026-05-27",
      "epss": "0.00162",
      "percentile": "0.36665"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:omron:sysmac_cs1_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1\", \"matchCriteriaId\": \"DC0EDECA-0697-4BF1-AC39-7DAEAFA79FE5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:omron:sysmac_cs1:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6F4E42A1-A6A5-4590-A369-C3E11C55979B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:omron:sysmac_cj2m_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.1\", \"matchCriteriaId\": \"FC2E363E-0118-4CA4-BD97-6C4FE939BA3E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:omron:sysmac_cj2m:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4EC6E3CB-486B-4C41-87D7-BF16D9B9FA74\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:omron:sysmac_cj2h_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.5\", \"matchCriteriaId\": \"464F762D-50B7-4BC7-87B8-C6E0CDBB05DA\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:omron:sysmac_cj2h:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"179BC3C6-8530-4680-8DAA-B8734C3F088A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:omron:sysmac_cp1e_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.30\", \"matchCriteriaId\": \"6C2FE1EA-5A52-4245-8F66-60A88F3C5E5C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:omron:sysmac_cp1e:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4A3E5CC5-3B48-4CD0-8CE0-F12AA0A8A1CA\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:omron:sysmac_cp1h_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.30\", \"matchCriteriaId\": \"9846BE46-9506-4434-BAA6-13A8AF687EC5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:omron:sysmac_cp1h:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1334C61E-D200-427B-833E-5FB538930F80\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:omron:sysmac_cp1l_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.10\", \"matchCriteriaId\": \"3AAB91A7-28FD-4462-AD62-40A010D3FD33\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:omron:sysmac_cp1l:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E74FC37C-0054-49E8-92CB-7BCF903D12C6\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:omron:cp1w-cif41_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"99A34BA8-7D88-4D08-A8F0-99570A397299\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:omron:cp1w-cif41:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"83911864-386F-40A2-BB2D-7E3443E3EDB8\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication.\"}, {\"lang\": \"es\", \"value\": \"En los PLC de las series CS, CJ y CP de Omron versiones hasta 18-05-2022, la contrase\\u00f1a de acceso a la Interfaz de Usuario Web es almacenada en el \\u00e1rea de memoria D1449...D1452 y puede leerse mediante el protocolo FINS de Omron sin necesidad de ninguna otra autenticaci\\u00f3n.\"}]",
      "id": "CVE-2022-31205",
      "lastModified": "2024-11-21T07:04:07.353",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
      "published": "2022-07-26T22:15:11.357",
      "references": "[{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.forescout.com/blog/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.forescout.com/blog/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-312\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-31205\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-07-26T22:15:11.357\",\"lastModified\":\"2024-11-21T07:04:07.353\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication.\"},{\"lang\":\"es\",\"value\":\"En los PLC de las series CS, CJ y CP de Omron versiones hasta 18-05-2022, la contrase\u00f1a de acceso a la Interfaz de Usuario Web es almacenada en el \u00e1rea de memoria D1449...D1452 y puede leerse mediante el protocolo FINS de Omron sin necesidad de ninguna otra autenticaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:omron:sysmac_cs1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1\",\"matchCriteriaId\":\"DC0EDECA-0697-4BF1-AC39-7DAEAFA79FE5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:omron:sysmac_cs1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F4E42A1-A6A5-4590-A369-C3E11C55979B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:omron:sysmac_cj2m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.1\",\"matchCriteriaId\":\"FC2E363E-0118-4CA4-BD97-6C4FE939BA3E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:omron:sysmac_cj2m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4EC6E3CB-486B-4C41-87D7-BF16D9B9FA74\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:omron:sysmac_cj2h_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.5\",\"matchCriteriaId\":\"464F762D-50B7-4BC7-87B8-C6E0CDBB05DA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:omron:sysmac_cj2h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"179BC3C6-8530-4680-8DAA-B8734C3F088A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:omron:sysmac_cp1e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.30\",\"matchCriteriaId\":\"6C2FE1EA-5A52-4245-8F66-60A88F3C5E5C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:omron:sysmac_cp1e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4A3E5CC5-3B48-4CD0-8CE0-F12AA0A8A1CA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:omron:sysmac_cp1h_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.30\",\"matchCriteriaId\":\"9846BE46-9506-4434-BAA6-13A8AF687EC5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:omron:sysmac_cp1h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1334C61E-D200-427B-833E-5FB538930F80\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:omron:sysmac_cp1l_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.10\",\"matchCriteriaId\":\"3AAB91A7-28FD-4462-AD62-40A010D3FD33\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:omron:sysmac_cp1l:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E74FC37C-0054-49E8-92CB-7BCF903D12C6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:omron:cp1w-cif41_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"99A34BA8-7D88-4D08-A8F0-99570A397299\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:omron:cp1w-cif41:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"83911864-386F-40A2-BB2D-7E3443E3EDB8\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.forescout.com/blog/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.forescout.com/blog/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…