Summary
In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:21:33.144Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/z1r00/IOT_Vul/blob/main/dlink/Dir816/Diagnosis/readme.md"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/726232111/VulIoT/tree/main/D-Link/DIR-816%20A2_v1.10CNB05/Diagnosis"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-03T00:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://github.com/z1r00/IOT_Vul/blob/main/dlink/Dir816/Diagnosis/readme.md"
},
{
"url": "https://github.com/726232111/VulIoT/tree/main/D-Link/DIR-816%20A2_v1.10CNB05/Diagnosis"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-37130",
"datePublished": "2022-08-31T00:00:00",
"dateReserved": "2022-08-01T00:00:00",
"dateUpdated": "2024-08-03T10:21:33.144Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dlink:dir-816_firmware:1.10cnb04:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"94848253-66CF-4F67-979E-0913F153A578\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dlink:dir-816:a2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1A3AC507-7219-401E-AC60-12D96382E4B7\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability\"}, {\"lang\": \"es\", \"value\": \"En D-Link DIR-816 versi\\u00f3n A2_v1.10CNB04.img, es producida una vulnerabilidad de inyecci\\u00f3n de comandos en /goform/Diagnosis, despu\\u00e9s de que es cumplida la condici\\u00f3n, setnum ser\\u00e1 empalmado con v10 mediante snprintf, y ser\\u00e1 ejecutado el sistema, resultando en una vulnerabilidad de inyecci\\u00f3n de comandos\"}]",
"id": "CVE-2022-37130",
"lastModified": "2024-11-21T07:14:29.807",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
"published": "2022-08-31T23:15:08.293",
"references": "[{\"url\": \"https://github.com/726232111/VulIoT/tree/main/D-Link/DIR-816%20A2_v1.10CNB05/Diagnosis\", \"source\": \"cve@mitre.org\"}, {\"url\": \"https://github.com/z1r00/IOT_Vul/blob/main/dlink/Dir816/Diagnosis/readme.md\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://www.dlink.com/en/security-bulletin/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://github.com/726232111/VulIoT/tree/main/D-Link/DIR-816%20A2_v1.10CNB05/Diagnosis\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://github.com/z1r00/IOT_Vul/blob/main/dlink/Dir816/Diagnosis/readme.md\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://www.dlink.com/en/security-bulletin/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-37130\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-08-31T23:15:08.293\",\"lastModified\":\"2024-11-21T07:14:29.807\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability\"},{\"lang\":\"es\",\"value\":\"En D-Link DIR-816 versi\u00f3n A2_v1.10CNB04.img, es producida una vulnerabilidad de inyecci\u00f3n de comandos en /goform/Diagnosis, despu\u00e9s de que es cumplida la condici\u00f3n, setnum ser\u00e1 empalmado con v10 mediante snprintf, y ser\u00e1 ejecutado el sistema, resultando en una vulnerabilidad de inyecci\u00f3n de comandos\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dlink:dir-816_firmware:1.10cnb04:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"94848253-66CF-4F67-979E-0913F153A578\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dlink:dir-816:a2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1A3AC507-7219-401E-AC60-12D96382E4B7\"}]}]}],\"references\":[{\"url\":\"https://github.com/726232111/VulIoT/tree/main/D-Link/DIR-816%20A2_v1.10CNB05/Diagnosis\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://github.com/z1r00/IOT_Vul/blob/main/dlink/Dir816/Diagnosis/readme.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.dlink.com/en/security-bulletin/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://github.com/726232111/VulIoT/tree/main/D-Link/DIR-816%20A2_v1.10CNB05/Diagnosis\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://github.com/z1r00/IOT_Vul/blob/main/dlink/Dir816/Diagnosis/readme.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.dlink.com/en/security-bulletin/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.