Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2022-41280
Vulnerability from cvelistv5
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | JT2Go |
Version: All versions < V14.1.0.6 |
|||||||||||||||||||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T12:42:44.071Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "JT2Go", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V14.1.0.6", }, ], }, { defaultStatus: "unknown", product: "Teamcenter Visualization V13.2", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V13.2.0.12", }, ], }, { defaultStatus: "unknown", product: "Teamcenter Visualization V13.3", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V13.3.0.8", }, ], }, { defaultStatus: "unknown", product: "Teamcenter Visualization V14.0", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V14.0.0.4", }, ], }, { defaultStatus: "unknown", product: "Teamcenter Visualization V14.1", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V14.1.0.6", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", }, ], metrics: [ { cvssV3_1: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-476", description: "CWE-476: NULL Pointer Dereference", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2023-04-11T09:02:40.259Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2022-41280", datePublished: "2022-12-13T00:00:00", dateReserved: "2022-09-21T00:00:00", dateUpdated: "2024-08-03T12:42:44.071Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { fkie_nvd: { configurations: "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:jt2go:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A264819D-B571-4E10-98CE-7D1E2C04D312\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"13.2.0\", \"versionEndExcluding\": \"13.2.0.12\", \"matchCriteriaId\": \"2CB3887E-4564-4715-B27F-5BE6757EE960\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"13.3.0\", \"versionEndExcluding\": \"13.3.0.8\", \"matchCriteriaId\": \"DF82E5C7-68B6-456B-9658-CCF1FB1DC4D9\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"14.0\", \"versionEndExcluding\": \"14.0.0.4\", \"matchCriteriaId\": \"B0296066-2DC4-407F-9AA9-49BE916988C8\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"14.1\", \"versionEndExcluding\": \"14.1.0.6\", \"matchCriteriaId\": \"D8922308-85AE-4EAE-BF4A-7CE54201713B\"}]}]}]", descriptions: "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en:\\nJT2Go (Todas las versiones < V14.1.0.6), \\nTeamcenter Visualization V13.2 (Todas las versiones < V13.2.0.12), \\nTeamcenter Visualization V13.3 (Todas las versiones < V13.3.0. 8), \\nTeamcenter Visualization V14.0 (todas las versiones < V14.0.0.4), \\nTeamcenter Visualization V14.1 (todas las versiones < V14.1.0.6). \\nCGM_NIST_Loader.dll contiene una vulnerabilidad de desreferencia de puntero nulo al analizar archivos CGM especialmente manipulados. Un atacante podr\\u00eda aprovechar esta vulnerabilidad para bloquear la aplicaci\\u00f3n y provocar una condici\\u00f3n de Denegaci\\u00f3n de Servicio (DoS).\"}]", id: "CVE-2022-41280", lastModified: "2024-11-21T07:22:58.197", metrics: "{\"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L\", \"baseScore\": 3.3, \"baseSeverity\": \"LOW\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 1.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}]}", published: "2022-12-13T16:15:22.290", references: "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: "[{\"source\": \"productcert@siemens.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-476\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-476\"}]}]", }, nvd: "{\"cve\":{\"id\":\"CVE-2022-41280\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-12-13T16:15:22.290\",\"lastModified\":\"2024-11-21T07:22:58.197\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en:\\nJT2Go (Todas las versiones < V14.1.0.6), \\nTeamcenter Visualization V13.2 (Todas las versiones < V13.2.0.12), \\nTeamcenter Visualization V13.3 (Todas las versiones < V13.3.0. 8), \\nTeamcenter Visualization V14.0 (todas las versiones < V14.0.0.4), \\nTeamcenter Visualization V14.1 (todas las versiones < V14.1.0.6). \\nCGM_NIST_Loader.dll contiene una vulnerabilidad de desreferencia de puntero nulo al analizar archivos CGM especialmente manipulados. Un atacante podría aprovechar esta vulnerabilidad para bloquear la aplicación y provocar una condición de Denegación de Servicio (DoS).\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-476\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-476\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A264819D-B571-4E10-98CE-7D1E2C04D312\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.0\",\"versionEndExcluding\":\"13.2.0.12\",\"matchCriteriaId\":\"2CB3887E-4564-4715-B27F-5BE6757EE960\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.3.0\",\"versionEndExcluding\":\"13.3.0.8\",\"matchCriteriaId\":\"DF82E5C7-68B6-456B-9658-CCF1FB1DC4D9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.0\",\"versionEndExcluding\":\"14.0.0.4\",\"matchCriteriaId\":\"B0296066-2DC4-407F-9AA9-49BE916988C8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.1\",\"versionEndExcluding\":\"14.1.0.6\",\"matchCriteriaId\":\"D8922308-85AE-4EAE-BF4A-7CE54201713B\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", }, }
WID-SEC-W-2022-2296
Vulnerability from csaf_certbund
Notes
{ document: { aggregate_severity: { text: "mittel", }, category: "csaf_base", csaf_version: "2.0", distribution: { tlp: { label: "WHITE", url: "https://www.first.org/tlp/", }, }, lang: "de-DE", notes: [ { category: "legal_disclaimer", text: "Das BSI ist als Anbieter für die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch dafür verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgfältig im Einzelfall zu prüfen.", }, { category: "description", text: "JT ist ein von Siemens Ditgital Industries entwickeltes Datenformat. JT2Go ist ein kostenloser Betrachter für 3D-JT-Daten.", title: "Produktbeschreibung", }, { category: "summary", text: "Ein lokaler Angreifer kann mehrere Schwachstellen in Siemens JT2Go ausnutzen, um beliebigen Programmcode mit den Rechten des Dienstes auszuführen oder einen Denial of Service zu verursachen.", title: "Angriff", }, { category: "general", text: "- Windows", title: "Betroffene Betriebssysteme", }, ], publisher: { category: "other", contact_details: "csaf-provider@cert-bund.de", name: "Bundesamt für Sicherheit in der Informationstechnik", namespace: "https://www.bsi.bund.de", }, references: [ { category: "self", summary: "WID-SEC-W-2022-2296 - CSAF Version", url: "https://wid.cert-bund.de/.well-known/csaf/white/2022/wid-sec-w-2022-2296.json", }, { category: "self", summary: "WID-SEC-2022-2296 - Portal Version", url: "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2022-2296", }, { category: "external", summary: "Siemens Security Advisory by Siemens ProductCERT vom 2022-12-12", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, { category: "external", summary: "Siemens Security Advisory by Siemens ProductCERT vom 2022-12-12", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-360681.pdf", }, ], source_lang: "en-US", title: "Siemens JT2Go: Mehrere Schwachstellen", tracking: { current_release_date: "2022-12-12T23:00:00.000+00:00", generator: { date: "2024-08-15T17:39:43.666+00:00", engine: { name: "BSI-WID", version: "1.3.5", }, }, id: "WID-SEC-W-2022-2296", initial_release_date: "2022-12-12T23:00:00.000+00:00", revision_history: [ { date: "2022-12-12T23:00:00.000+00:00", number: "1", summary: "Initiale Fassung", }, ], status: "final", version: "1", }, }, product_tree: { branches: [ { branches: [ { branches: [ { category: "product_name", name: "Siemens JT2Go", product: { name: "Siemens JT2Go", product_id: "862941", product_identification_helper: { cpe: "cpe:/a:siemens:jt2go:-", }, }, }, { category: "product_name", name: "Siemens JT2Go < 14.1.0.5", product: { name: "Siemens JT2Go < 14.1.0.5", product_id: "T025557", product_identification_helper: { cpe: "cpe:/a:siemens:jt2go:v14.1.0.5", }, }, }, ], category: "product_name", name: "JT2Go", }, ], category: "vendor", name: "Siemens", }, ], }, vulnerabilities: [ { cve: "CVE-2022-41286", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41286", }, { cve: "CVE-2022-41285", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41285", }, { cve: "CVE-2022-41284", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41284", }, { cve: "CVE-2022-41283", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41283", }, { cve: "CVE-2022-41282", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41282", }, { cve: "CVE-2022-41281", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41281", }, { cve: "CVE-2022-45484", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-45484", }, { cve: "CVE-2022-41288", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41288", }, { cve: "CVE-2022-41287", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41287", }, { cve: "CVE-2022-41280", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41280", }, { cve: "CVE-2022-41279", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41279", }, { cve: "CVE-2022-41278", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41278", }, { cve: "CVE-2022-3161", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der APDFL.dll. Diese beruhen auf Pufferüberläufen und Fehlern in der Speicherverwaltung beim Parsen speziell gestalteter PDF-Dateien. Ein Angreifer kann diese Schwachstelle ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-3161", }, { cve: "CVE-2022-3160", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der APDFL.dll. Diese beruhen auf Pufferüberläufen und Fehlern in der Speicherverwaltung beim Parsen speziell gestalteter PDF-Dateien. Ein Angreifer kann diese Schwachstelle ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-3160", }, { cve: "CVE-2022-3159", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der APDFL.dll. Diese beruhen auf Pufferüberläufen und Fehlern in der Speicherverwaltung beim Parsen speziell gestalteter PDF-Dateien. Ein Angreifer kann diese Schwachstelle ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-3159", }, ], }
wid-sec-w-2022-2296
Vulnerability from csaf_certbund
Notes
{ document: { aggregate_severity: { text: "mittel", }, category: "csaf_base", csaf_version: "2.0", distribution: { tlp: { label: "WHITE", url: "https://www.first.org/tlp/", }, }, lang: "de-DE", notes: [ { category: "legal_disclaimer", text: "Das BSI ist als Anbieter für die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch dafür verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgfältig im Einzelfall zu prüfen.", }, { category: "description", text: "JT ist ein von Siemens Ditgital Industries entwickeltes Datenformat. JT2Go ist ein kostenloser Betrachter für 3D-JT-Daten.", title: "Produktbeschreibung", }, { category: "summary", text: "Ein lokaler Angreifer kann mehrere Schwachstellen in Siemens JT2Go ausnutzen, um beliebigen Programmcode mit den Rechten des Dienstes auszuführen oder einen Denial of Service zu verursachen.", title: "Angriff", }, { category: "general", text: "- Windows", title: "Betroffene Betriebssysteme", }, ], publisher: { category: "other", contact_details: "csaf-provider@cert-bund.de", name: "Bundesamt für Sicherheit in der Informationstechnik", namespace: "https://www.bsi.bund.de", }, references: [ { category: "self", summary: "WID-SEC-W-2022-2296 - CSAF Version", url: "https://wid.cert-bund.de/.well-known/csaf/white/2022/wid-sec-w-2022-2296.json", }, { category: "self", summary: "WID-SEC-2022-2296 - Portal Version", url: "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2022-2296", }, { category: "external", summary: "Siemens Security Advisory by Siemens ProductCERT vom 2022-12-12", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, { category: "external", summary: "Siemens Security Advisory by Siemens ProductCERT vom 2022-12-12", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-360681.pdf", }, ], source_lang: "en-US", title: "Siemens JT2Go: Mehrere Schwachstellen", tracking: { current_release_date: "2022-12-12T23:00:00.000+00:00", generator: { date: "2024-08-15T17:39:43.666+00:00", engine: { name: "BSI-WID", version: "1.3.5", }, }, id: "WID-SEC-W-2022-2296", initial_release_date: "2022-12-12T23:00:00.000+00:00", revision_history: [ { date: "2022-12-12T23:00:00.000+00:00", number: "1", summary: "Initiale Fassung", }, ], status: "final", version: "1", }, }, product_tree: { branches: [ { branches: [ { branches: [ { category: "product_name", name: "Siemens JT2Go", product: { name: "Siemens JT2Go", product_id: "862941", product_identification_helper: { cpe: "cpe:/a:siemens:jt2go:-", }, }, }, { category: "product_name", name: "Siemens JT2Go < 14.1.0.5", product: { name: "Siemens JT2Go < 14.1.0.5", product_id: "T025557", product_identification_helper: { cpe: "cpe:/a:siemens:jt2go:v14.1.0.5", }, }, }, ], category: "product_name", name: "JT2Go", }, ], category: "vendor", name: "Siemens", }, ], }, vulnerabilities: [ { cve: "CVE-2022-41286", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41286", }, { cve: "CVE-2022-41285", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41285", }, { cve: "CVE-2022-41284", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41284", }, { cve: "CVE-2022-41283", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41283", }, { cve: "CVE-2022-41282", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41282", }, { cve: "CVE-2022-41281", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese bestehen aufgrund von Out-of-bounds Read, Out-of-bounds Write und Use After Free Problemen beim Parsen von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41281", }, { cve: "CVE-2022-45484", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-45484", }, { cve: "CVE-2022-41288", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41288", }, { cve: "CVE-2022-41287", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41287", }, { cve: "CVE-2022-41280", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41280", }, { cve: "CVE-2022-41279", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41279", }, { cve: "CVE-2022-41278", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der CGM_NIST_Loader.dll. Diese beruhen auf Nullzeiger-Dereferenzierungen und Fehlern in der Speicherbehandlung während des Parsens von CGM Dateien. Ein Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service zu verursachen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-41278", }, { cve: "CVE-2022-3161", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der APDFL.dll. Diese beruhen auf Pufferüberläufen und Fehlern in der Speicherverwaltung beim Parsen speziell gestalteter PDF-Dateien. Ein Angreifer kann diese Schwachstelle ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-3161", }, { cve: "CVE-2022-3160", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der APDFL.dll. Diese beruhen auf Pufferüberläufen und Fehlern in der Speicherverwaltung beim Parsen speziell gestalteter PDF-Dateien. Ein Angreifer kann diese Schwachstelle ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-3160", }, { cve: "CVE-2022-3159", notes: [ { category: "description", text: "In Siemens JT2Go existieren mehrere Schwachstellen in der APDFL.dll. Diese beruhen auf Pufferüberläufen und Fehlern in der Speicherverwaltung beim Parsen speziell gestalteter PDF-Dateien. Ein Angreifer kann diese Schwachstelle ausnutzen, um Code im Kontext des aktuellen Prozesses auszuführen. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich.", }, ], product_status: { known_affected: [ "862941", ], }, release_date: "2022-12-12T23:00:00.000+00:00", title: "CVE-2022-3159", }, ], }
icsa-22-349-20
Vulnerability from csaf_cisa
Notes
{ document: { acknowledgments: [ { organization: "Siemens ProductCERT", summary: "reporting these vulnerabilities to CISA.", }, ], category: "csaf_security_advisory", csaf_version: "2.0", distribution: { text: "Disclosure is not limited", tlp: { label: "WHITE", url: "https://us-cert.cisa.gov/tlp/", }, }, lang: "en", notes: [ { category: "summary", text: "Siemens Teamcenter Visualization and JT2Go are affected by multiple file parsing vulnerabilities that could be triggered when the application reads a malicious file in CGM or RAS format. If a user is tricked to open a malicious file with the affected products, this could lead the application to crash or potentially lead to arbitrary code execution.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.", title: "Summary", }, { category: "general", text: "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", title: "General Recommendations", }, { category: "general", text: "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", title: "Additional Resources", }, { category: "legal_disclaimer", text: "Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", title: "Terms of Use", }, { category: "legal_disclaimer", text: "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", title: "Legal Notice", }, { category: "other", text: "This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.", title: "Advisory Conversion Disclaimer", }, { category: "other", text: "Multiple", title: "Critical infrastructure sectors", }, { category: "other", text: "Worldwide", title: "Countries/areas deployed", }, { category: "other", text: "Germany", title: "Company headquarters location", }, { category: "general", text: "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", title: "Recommended Practices", }, { category: "general", text: "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", title: "Recommended Practices", }, { category: "general", text: "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", title: "Recommended Practices", }, { category: "general", text: "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", title: "Recommended Practices", }, { category: "general", text: "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", title: "Recommended Practices", }, { category: "general", text: "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", title: "Recommended Practices", }, { category: "general", text: "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", title: "Recommended Practices", }, { category: "general", text: "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", title: "Recommended Practices", }, ], publisher: { category: "other", contact_details: "central@cisa.dhs.gov", name: "CISA", namespace: "https://www.cisa.gov/", }, references: [ { category: "self", summary: "SSA-700053: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - CSAF Version", url: "https://cert-portal.siemens.com/productcert/csaf/ssa-700053.json", }, { category: "self", summary: "SSA-700053: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - HTML Version", url: "https://cert-portal.siemens.com/productcert/html/ssa-700053.html", }, { category: "self", summary: "SSA-700053: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - PDF Version", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, { category: "self", summary: "SSA-700053: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - TXT Version", url: "https://cert-portal.siemens.com/productcert/txt/ssa-700053.txt", }, { category: "self", summary: "ICS Advisory ICSA-22-349-20 JSON", url: "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-349-20.json", }, { category: "self", summary: "ICS Advisory ICSA-22-349-20 - Web Version", url: "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-20", }, { category: "external", summary: "Recommended Practices", url: "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01", }, { category: "external", summary: "Recommended Practices", url: "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices", }, { category: "external", summary: "Recommended Practices", url: "https://www.cisa.gov/topics/industrial-control-systems", }, { category: "external", summary: "Recommended Practices", url: "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf", }, { category: "external", summary: "Recommended Practices", url: "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf", }, { category: "external", summary: "Recommended Practices", url: "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B", }, ], title: "Siemens Teamcenter Visualization and JT2Go", tracking: { current_release_date: "2023-04-11T00:00:00.000000Z", generator: { engine: { name: "CISA CSAF Generator", version: "1.0.0", }, }, id: "ICSA-22-349-20", initial_release_date: "2022-12-13T00:00:00.000000Z", revision_history: [ { date: "2022-12-13T00:00:00.000000Z", legacy_version: "1.0", number: "1", summary: "Publication Date", }, { date: "2023-03-14T00:00:00.000000Z", legacy_version: "1.1", number: "2", summary: "Added remediation for Teamcenter Visualization version lines V13.3 and V14.0 for CVE-2022-45484", }, { date: "2023-04-11T00:00:00.000000Z", legacy_version: "1.2", number: "3", summary: "Added fix for JT2Go", }, ], status: "final", version: "3", }, }, product_tree: { branches: [ { branches: [ { branches: [ { category: "product_version_range", name: "vers:all/<V14.1.0.6", product: { name: "JT2Go", product_id: "CSAFPID-0001", }, }, ], category: "product_name", name: "JT2Go", }, { branches: [ { category: "product_version_range", name: "vers:all/<V13.2.0.12", product: { name: "Teamcenter Visualization V13.2", product_id: "CSAFPID-0002", }, }, ], category: "product_name", name: "Teamcenter Visualization V13.2", }, { branches: [ { category: "product_version_range", name: "vers:all/<V13.3.0.9", product: { name: "Teamcenter Visualization V13.3", product_id: "CSAFPID-0003", }, }, { category: "product_version_range", name: "vers:all/<V13.3.0.8", product: { name: "Teamcenter Visualization V13.3", product_id: "CSAFPID-0004", }, }, ], category: "product_name", name: "Teamcenter Visualization V13.3", }, { branches: [ { category: "product_version_range", name: "vers:all/<V14.0.0.5", product: { name: "Teamcenter Visualization V14.0", product_id: "CSAFPID-0005", }, }, { category: "product_version_range", name: "vers:all/<V14.0.0.4", product: { name: "Teamcenter Visualization V14.0", product_id: "CSAFPID-0006", }, }, ], category: "product_name", name: "Teamcenter Visualization V14.0", }, { branches: [ { category: "product_version_range", name: "vers:all/<V14.1.0.6", product: { name: "Teamcenter Visualization V14.1", product_id: "CSAFPID-0007", }, }, ], category: "product_name", name: "Teamcenter Visualization V14.1", }, ], category: "vendor", name: "Siemens", }, ], }, vulnerabilities: [ { cve: "CVE-2022-41278", cwe: { id: "CWE-476", name: "NULL Pointer Dereference", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41278", }, { cve: "CVE-2022-41279", cwe: { id: "CWE-476", name: "NULL Pointer Dereference", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41279", }, { cve: "CVE-2022-41280", cwe: { id: "CWE-476", name: "NULL Pointer Dereference", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41280", }, { cve: "CVE-2022-41281", cwe: { id: "CWE-125", name: "Out-of-bounds Read", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41281", }, { cve: "CVE-2022-41282", cwe: { id: "CWE-125", name: "Out-of-bounds Read", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41282", }, { cve: "CVE-2022-41283", cwe: { id: "CWE-787", name: "Out-of-bounds Write", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains an out of bounds write vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41283", }, { cve: "CVE-2022-41284", cwe: { id: "CWE-125", name: "Out-of-bounds Read", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41284", }, { cve: "CVE-2022-41285", cwe: { id: "CWE-416", name: "Use After Free", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains a use-after-free vulnerability that could be triggered while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41285", }, { cve: "CVE-2022-41286", cwe: { id: "CWE-125", name: "Out-of-bounds Read", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains an out of bounds write vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41286", }, { cve: "CVE-2022-41287", cwe: { id: "CWE-369", name: "Divide By Zero", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains divide by zero vulnerability when parsing a CGM file. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41287", }, { cve: "CVE-2022-41288", cwe: { id: "CWE-770", name: "Allocation of Resources Without Limits or Throttling", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains stack exhaustion vulnerability when parsing a CGM file. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41288", }, { cve: "CVE-2022-45484", cwe: { id: "CWE-125", name: "Out-of-bounds Read", }, notes: [ { category: "summary", text: "The CCITT_G4Decode.dll contains an out of bounds read vulnerability when parsing a RAS file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19056)", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V13.3.0.9 or later version", product_ids: [ "CSAFPID-0003", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.5 or later version", product_ids: [ "CSAFPID-0005", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-45484", }, ], }
ICSA-22-349-20
Vulnerability from csaf_cisa
Notes
{ document: { acknowledgments: [ { organization: "Siemens ProductCERT", summary: "reporting these vulnerabilities to CISA.", }, ], category: "csaf_security_advisory", csaf_version: "2.0", distribution: { text: "Disclosure is not limited", tlp: { label: "WHITE", url: "https://us-cert.cisa.gov/tlp/", }, }, lang: "en", notes: [ { category: "summary", text: "Siemens Teamcenter Visualization and JT2Go are affected by multiple file parsing vulnerabilities that could be triggered when the application reads a malicious file in CGM or RAS format. If a user is tricked to open a malicious file with the affected products, this could lead the application to crash or potentially lead to arbitrary code execution.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.", title: "Summary", }, { category: "general", text: "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", title: "General Recommendations", }, { category: "general", text: "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", title: "Additional Resources", }, { category: "legal_disclaimer", text: "Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", title: "Terms of Use", }, { category: "legal_disclaimer", text: "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", title: "Legal Notice", }, { category: "other", text: "This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.", title: "Advisory Conversion Disclaimer", }, { category: "other", text: "Multiple", title: "Critical infrastructure sectors", }, { category: "other", text: "Worldwide", title: "Countries/areas deployed", }, { category: "other", text: "Germany", title: "Company headquarters location", }, { category: "general", text: "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", title: "Recommended Practices", }, { category: "general", text: "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", title: "Recommended Practices", }, { category: "general", text: "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", title: "Recommended Practices", }, { category: "general", text: "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", title: "Recommended Practices", }, { category: "general", text: "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", title: "Recommended Practices", }, { category: "general", text: "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", title: "Recommended Practices", }, { category: "general", text: "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", title: "Recommended Practices", }, { category: "general", text: "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", title: "Recommended Practices", }, ], publisher: { category: "other", contact_details: "central@cisa.dhs.gov", name: "CISA", namespace: "https://www.cisa.gov/", }, references: [ { category: "self", summary: "SSA-700053: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - CSAF Version", url: "https://cert-portal.siemens.com/productcert/csaf/ssa-700053.json", }, { category: "self", summary: "SSA-700053: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - HTML Version", url: "https://cert-portal.siemens.com/productcert/html/ssa-700053.html", }, { category: "self", summary: "SSA-700053: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - PDF Version", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, { category: "self", summary: "SSA-700053: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - TXT Version", url: "https://cert-portal.siemens.com/productcert/txt/ssa-700053.txt", }, { category: "self", summary: "ICS Advisory ICSA-22-349-20 JSON", url: "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-349-20.json", }, { category: "self", summary: "ICS Advisory ICSA-22-349-20 - Web Version", url: "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-20", }, { category: "external", summary: "Recommended Practices", url: "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01", }, { category: "external", summary: "Recommended Practices", url: "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices", }, { category: "external", summary: "Recommended Practices", url: "https://www.cisa.gov/topics/industrial-control-systems", }, { category: "external", summary: "Recommended Practices", url: "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf", }, { category: "external", summary: "Recommended Practices", url: "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf", }, { category: "external", summary: "Recommended Practices", url: "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B", }, ], title: "Siemens Teamcenter Visualization and JT2Go", tracking: { current_release_date: "2023-04-11T00:00:00.000000Z", generator: { engine: { name: "CISA CSAF Generator", version: "1.0.0", }, }, id: "ICSA-22-349-20", initial_release_date: "2022-12-13T00:00:00.000000Z", revision_history: [ { date: "2022-12-13T00:00:00.000000Z", legacy_version: "1.0", number: "1", summary: "Publication Date", }, { date: "2023-03-14T00:00:00.000000Z", legacy_version: "1.1", number: "2", summary: "Added remediation for Teamcenter Visualization version lines V13.3 and V14.0 for CVE-2022-45484", }, { date: "2023-04-11T00:00:00.000000Z", legacy_version: "1.2", number: "3", summary: "Added fix for JT2Go", }, ], status: "final", version: "3", }, }, product_tree: { branches: [ { branches: [ { branches: [ { category: "product_version_range", name: "vers:all/<V14.1.0.6", product: { name: "JT2Go", product_id: "CSAFPID-0001", }, }, ], category: "product_name", name: "JT2Go", }, { branches: [ { category: "product_version_range", name: "vers:all/<V13.2.0.12", product: { name: "Teamcenter Visualization V13.2", product_id: "CSAFPID-0002", }, }, ], category: "product_name", name: "Teamcenter Visualization V13.2", }, { branches: [ { category: "product_version_range", name: "vers:all/<V13.3.0.9", product: { name: "Teamcenter Visualization V13.3", product_id: "CSAFPID-0003", }, }, { category: "product_version_range", name: "vers:all/<V13.3.0.8", product: { name: "Teamcenter Visualization V13.3", product_id: "CSAFPID-0004", }, }, ], category: "product_name", name: "Teamcenter Visualization V13.3", }, { branches: [ { category: "product_version_range", name: "vers:all/<V14.0.0.5", product: { name: "Teamcenter Visualization V14.0", product_id: "CSAFPID-0005", }, }, { category: "product_version_range", name: "vers:all/<V14.0.0.4", product: { name: "Teamcenter Visualization V14.0", product_id: "CSAFPID-0006", }, }, ], category: "product_name", name: "Teamcenter Visualization V14.0", }, { branches: [ { category: "product_version_range", name: "vers:all/<V14.1.0.6", product: { name: "Teamcenter Visualization V14.1", product_id: "CSAFPID-0007", }, }, ], category: "product_name", name: "Teamcenter Visualization V14.1", }, ], category: "vendor", name: "Siemens", }, ], }, vulnerabilities: [ { cve: "CVE-2022-41278", cwe: { id: "CWE-476", name: "NULL Pointer Dereference", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41278", }, { cve: "CVE-2022-41279", cwe: { id: "CWE-476", name: "NULL Pointer Dereference", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41279", }, { cve: "CVE-2022-41280", cwe: { id: "CWE-476", name: "NULL Pointer Dereference", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41280", }, { cve: "CVE-2022-41281", cwe: { id: "CWE-125", name: "Out-of-bounds Read", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41281", }, { cve: "CVE-2022-41282", cwe: { id: "CWE-125", name: "Out-of-bounds Read", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41282", }, { cve: "CVE-2022-41283", cwe: { id: "CWE-787", name: "Out-of-bounds Write", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains an out of bounds write vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41283", }, { cve: "CVE-2022-41284", cwe: { id: "CWE-125", name: "Out-of-bounds Read", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41284", }, { cve: "CVE-2022-41285", cwe: { id: "CWE-416", name: "Use After Free", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains a use-after-free vulnerability that could be triggered while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41285", }, { cve: "CVE-2022-41286", cwe: { id: "CWE-125", name: "Out-of-bounds Read", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains an out of bounds write vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41286", }, { cve: "CVE-2022-41287", cwe: { id: "CWE-369", name: "Divide By Zero", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains divide by zero vulnerability when parsing a CGM file. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41287", }, { cve: "CVE-2022-41288", cwe: { id: "CWE-770", name: "Allocation of Resources Without Limits or Throttling", }, notes: [ { category: "summary", text: "The CGM_NIST_Loader.dll contains stack exhaustion vulnerability when parsing a CGM file. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-41288", }, { cve: "CVE-2022-45484", cwe: { id: "CWE-125", name: "Out-of-bounds Read", }, notes: [ { category: "summary", text: "The CCITT_G4Decode.dll contains an out of bounds read vulnerability when parsing a RAS file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19056)", title: "Summary", }, ], product_status: { known_affected: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", ], }, remediations: [ { category: "mitigation", details: "Do not open untrusted CGM or RAS files in JT2Go and Teamcenter Visualization", product_ids: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", ], }, { category: "vendor_fix", details: "Update to V13.3.0.9 or later version", product_ids: [ "CSAFPID-0003", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.5 or later version", product_ids: [ "CSAFPID-0005", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0001", ], url: "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html", }, { category: "vendor_fix", details: "Update to V13.3.0.8 or later version", product_ids: [ "CSAFPID-0004", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.0.0.4 or later version", product_ids: [ "CSAFPID-0006", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V14.1.0.6 or later version", product_ids: [ "CSAFPID-0007", ], url: "https://support.sw.siemens.com/", }, { category: "vendor_fix", details: "Update to V13.2.0.12 or later version", product_ids: [ "CSAFPID-0002", ], url: "https://support.sw.siemens.com/", }, ], scores: [ { cvss_v3: { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, products: [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", ], }, ], title: "CVE-2022-45484", }, ], }
fkie_cve-2022-41280
Vulnerability from fkie_nvd
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
Vendor | Product | Version | |
---|---|---|---|
siemens | jt2go | - | |
siemens | teamcenter_visualization | * | |
siemens | teamcenter_visualization | * | |
siemens | teamcenter_visualization | * | |
siemens | teamcenter_visualization | * |
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:jt2go:-:*:*:*:*:*:*:*", matchCriteriaId: "A264819D-B571-4E10-98CE-7D1E2C04D312", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", matchCriteriaId: "2CB3887E-4564-4715-B27F-5BE6757EE960", versionEndExcluding: "13.2.0.12", versionStartIncluding: "13.2.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", matchCriteriaId: "DF82E5C7-68B6-456B-9658-CCF1FB1DC4D9", versionEndExcluding: "13.3.0.8", versionStartIncluding: "13.3.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", matchCriteriaId: "B0296066-2DC4-407F-9AA9-49BE916988C8", versionEndExcluding: "14.0.0.4", versionStartIncluding: "14.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", matchCriteriaId: "D8922308-85AE-4EAE-BF4A-7CE54201713B", versionEndExcluding: "14.1.0.6", versionStartIncluding: "14.1", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en:\nJT2Go (Todas las versiones < V14.1.0.6), \nTeamcenter Visualization V13.2 (Todas las versiones < V13.2.0.12), \nTeamcenter Visualization V13.3 (Todas las versiones < V13.3.0. 8), \nTeamcenter Visualization V14.0 (todas las versiones < V14.0.0.4), \nTeamcenter Visualization V14.1 (todas las versiones < V14.1.0.6). \nCGM_NIST_Loader.dll contiene una vulnerabilidad de desreferencia de puntero nulo al analizar archivos CGM especialmente manipulados. Un atacante podría aprovechar esta vulnerabilidad para bloquear la aplicación y provocar una condición de Denegación de Servicio (DoS).", }, ], id: "CVE-2022-41280", lastModified: "2024-11-21T07:22:58.197", metrics: { cvssMetricV31: [ { cvssData: { attackComplexity: "LOW", attackVector: "LOCAL", availabilityImpact: "LOW", baseScore: 3.3, baseSeverity: "LOW", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "REQUIRED", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", version: "3.1", }, exploitabilityScore: 1.8, impactScore: 1.4, source: "productcert@siemens.com", type: "Primary", }, { cvssData: { attackComplexity: "LOW", attackVector: "LOCAL", availabilityImpact: "HIGH", baseScore: 5.5, baseSeverity: "MEDIUM", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "REQUIRED", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", version: "3.1", }, exploitabilityScore: 1.8, impactScore: 3.6, source: "nvd@nist.gov", type: "Secondary", }, ], }, published: "2022-12-13T16:15:22.290", references: [ { source: "productcert@siemens.com", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-476", }, ], source: "productcert@siemens.com", type: "Primary", }, { description: [ { lang: "en", value: "CWE-476", }, ], source: "nvd@nist.gov", type: "Secondary", }, ], }
gsd-2022-41280
Vulnerability from gsd
{ GSD: { alias: "CVE-2022-41280", id: "GSD-2022-41280", }, gsd: { metadata: { exploitCode: "unknown", remediation: "unknown", reportConfidence: "confirmed", type: "vulnerability", }, osvSchema: { aliases: [ "CVE-2022-41280", ], details: "A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", id: "GSD-2022-41280", modified: "2023-12-13T01:19:32.868413Z", schema_version: "1.4.0", }, }, namespaces: { "cve.org": { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2022-41280", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "JT2Go", version: { version_data: [ { version_affected: "=", version_value: "All versions < V14.1.0.6", }, ], }, }, { product_name: "Teamcenter Visualization V13.2", version: { version_data: [ { version_affected: "=", version_value: "All versions < V13.2.0.12", }, ], }, }, { product_name: "Teamcenter Visualization V13.3", version: { version_data: [ { version_affected: "=", version_value: "All versions < V13.3.0.8", }, ], }, }, { product_name: "Teamcenter Visualization V14.0", version: { version_data: [ { version_affected: "=", version_value: "All versions < V14.0.0.4", }, ], }, }, { product_name: "Teamcenter Visualization V14.1", version: { version_data: [ { version_affected: "=", version_value: "All versions < V14.1.0.6", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", }, ], }, impact: { cvss: [ { baseScore: 3.3, baseSeverity: "LOW", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", version: "3.1", }, ], }, problemtype: { problemtype_data: [ { description: [ { cweId: "CWE-476", lang: "eng", value: "CWE-476: NULL Pointer Dereference", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, ], }, }, "nvd.nist.gov": { configurations: { CVE_data_version: "4.0", nodes: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "14.1.0.6", versionStartIncluding: "14.1", vulnerable: true, }, { cpe23Uri: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "14.0.0.4", versionStartIncluding: "14.0", vulnerable: true, }, { cpe23Uri: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "13.3.0.8", versionStartIncluding: "13.3.0", vulnerable: true, }, { cpe23Uri: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "13.2.0.12", versionStartIncluding: "13.2.0", vulnerable: true, }, { cpe23Uri: "cpe:2.3:a:siemens:jt2go:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: true, }, ], operator: "OR", }, ], }, cve: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2022-41280", }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "en", value: "A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "en", value: "CWE-476", }, ], }, ], }, references: { reference_data: [ { name: "N/A", refsource: "CONFIRM", tags: [ "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, ], }, }, impact: { baseMetricV3: { cvssV3: { attackComplexity: "LOW", attackVector: "LOCAL", availabilityImpact: "LOW", baseScore: 3.3, baseSeverity: "LOW", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "REQUIRED", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", version: "3.1", }, exploitabilityScore: 1.8, impactScore: 1.4, }, }, lastModifiedDate: "2023-04-11T10:15Z", publishedDate: "2022-12-13T16:15Z", }, }, }
var-202212-1170
Vulnerability from variot
A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. Siemens' JT2Go and Teamcenter Visualization for, NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", affected_products: { "@id": "https://www.variotdbs.pl/ref/affected_products", }, configurations: { "@id": "https://www.variotdbs.pl/ref/configurations", }, credits: { "@id": "https://www.variotdbs.pl/ref/credits", }, cvss: { "@id": "https://www.variotdbs.pl/ref/cvss/", }, description: { "@id": "https://www.variotdbs.pl/ref/description/", }, exploit_availability: { "@id": "https://www.variotdbs.pl/ref/exploit_availability/", }, external_ids: { "@id": "https://www.variotdbs.pl/ref/external_ids/", }, iot: { "@id": "https://www.variotdbs.pl/ref/iot/", }, iot_taxonomy: { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/", }, patch: { "@id": "https://www.variotdbs.pl/ref/patch/", }, problemtype_data: { "@id": "https://www.variotdbs.pl/ref/problemtype_data/", }, references: { "@id": "https://www.variotdbs.pl/ref/references/", }, sources: { "@id": "https://www.variotdbs.pl/ref/sources/", }, sources_release_date: { "@id": "https://www.variotdbs.pl/ref/sources_release_date/", }, sources_update_date: { "@id": "https://www.variotdbs.pl/ref/sources_update_date/", }, threat_type: { "@id": "https://www.variotdbs.pl/ref/threat_type/", }, title: { "@id": "https://www.variotdbs.pl/ref/title/", }, type: { "@id": "https://www.variotdbs.pl/ref/type/", }, }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1170", affected_products: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, "@id": "https://www.variotdbs.pl/ref/sources", }, }, data: [ { model: "teamcenter visualization", scope: "lt", trust: 1, vendor: "siemens", version: "13.2.0.12", }, { model: "teamcenter visualization", scope: "lt", trust: 1, vendor: "siemens", version: "14.1.0.6", }, { model: "teamcenter visualization", scope: "gte", trust: 1, vendor: "siemens", version: "13.2.0", }, { model: "teamcenter visualization", scope: "lt", trust: 1, vendor: "siemens", version: "13.3.0.8", }, { model: "teamcenter visualization", scope: "gte", trust: 1, vendor: "siemens", version: "14.1", }, { model: "jt2go", scope: "eq", trust: 1, vendor: "siemens", version: null, }, { model: "teamcenter visualization", scope: "gte", trust: 1, vendor: "siemens", version: "14.0", }, { model: "teamcenter visualization", scope: "gte", trust: 1, vendor: "siemens", version: "13.3.0", }, { model: "teamcenter visualization", scope: "lt", trust: 1, vendor: "siemens", version: "14.0.0.4", }, { model: "teamcenter visualization", scope: null, trust: 0.8, vendor: "シーメンス", version: null, }, { model: "jt2go", scope: null, trust: 0.8, vendor: "シーメンス", version: null, }, ], sources: [ { db: "JVNDB", id: "JVNDB-2022-023192", }, { db: "NVD", id: "CVE-2022-41280", }, ], }, configurations: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", children: { "@container": "@list", }, cpe_match: { "@container": "@list", }, data: { "@container": "@list", }, nodes: { "@container": "@list", }, }, data: [ { CVE_data_version: "4.0", nodes: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "14.1.0.6", versionStartIncluding: "14.1", vulnerable: true, }, { cpe23Uri: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "14.0.0.4", versionStartIncluding: "14.0", vulnerable: true, }, { cpe23Uri: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "13.3.0.8", versionStartIncluding: "13.3.0", vulnerable: true, }, { cpe23Uri: "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "13.2.0.12", versionStartIncluding: "13.2.0", vulnerable: true, }, { cpe23Uri: "cpe:2.3:a:siemens:jt2go:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: true, }, ], operator: "OR", }, ], }, ], sources: [ { db: "NVD", id: "CVE-2022-41280", }, ], }, cve: "CVE-2022-41280", cvss: { "@context": { cvssV2: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#", }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2", }, cvssV3: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#", }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/", }, severity: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#", }, "@id": "https://www.variotdbs.pl/ref/cvss/severity", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, "@id": "https://www.variotdbs.pl/ref/sources", }, }, data: [ { cvssV2: [], cvssV3: [ { attackComplexity: "LOW", attackVector: "LOCAL", author: "productcert@siemens.com", availabilityImpact: "LOW", baseScore: 3.3, baseSeverity: "LOW", confidentialityImpact: "NONE", exploitabilityScore: 1.8, impactScore: 1.4, integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", trust: 1, userInteraction: "REQUIRED", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", version: "3.1", }, { attackComplexity: "LOW", attackVector: "LOCAL", author: "NVD", availabilityImpact: "HIGH", baseScore: 5.5, baseSeverity: "MEDIUM", confidentialityImpact: "NONE", exploitabilityScore: 1.8, impactScore: 3.6, integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", trust: 1, userInteraction: "REQUIRED", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", version: "3.1", }, { attackComplexity: "Low", attackVector: "Local", author: "OTHER", availabilityImpact: "Low", baseScore: 3.3, baseSeverity: "Low", confidentialityImpact: "None", exploitabilityScore: null, id: "JVNDB-2022-023192", impactScore: null, integrityImpact: "None", privilegesRequired: "None", scope: "Unchanged", trust: 0.8, userInteraction: "Required", vectorString: "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", version: "3.0", }, ], severity: [ { author: "productcert@siemens.com", id: "CVE-2022-41280", trust: 1, value: "LOW", }, { author: "NVD", id: "CVE-2022-41280", trust: 1, value: "MEDIUM", }, { author: "OTHER", id: "JVNDB-2022-023192", trust: 0.8, value: "Low", }, { author: "CNNVD", id: "CNNVD-202212-3112", trust: 0.6, value: "LOW", }, ], }, ], sources: [ { db: "JVNDB", id: "JVNDB-2022-023192", }, { db: "NVD", id: "CVE-2022-41280", }, { db: "NVD", id: "CVE-2022-41280", }, { db: "CNNVD", id: "CNNVD-202212-3112", }, ], }, description: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: "A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. Siemens' JT2Go and Teamcenter Visualization for, NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state", sources: [ { db: "NVD", id: "CVE-2022-41280", }, { db: "JVNDB", id: "JVNDB-2022-023192", }, ], trust: 1.62, }, external_ids: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { db: "NVD", id: "CVE-2022-41280", trust: 3.2, }, { db: "SIEMENS", id: "SSA-700053", trust: 2.4, }, { db: "ICS CERT", id: "ICSA-22-349-20", trust: 0.8, }, { db: "JVN", id: "JVNVU91561630", trust: 0.8, }, { db: "JVNDB", id: "JVNDB-2022-023192", trust: 0.8, }, { db: "CNNVD", id: "CNNVD-202212-3112", trust: 0.6, }, ], sources: [ { db: "JVNDB", id: "JVNDB-2022-023192", }, { db: "NVD", id: "CVE-2022-41280", }, { db: "CNNVD", id: "CNNVD-202212-3112", }, ], }, id: "VAR-202212-1170", iot: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: true, sources: [ { db: "VARIoT devices database", id: null, }, ], trust: 0.15799868, }, last_update_date: "2023-12-18T10:47:06.100000Z", patch: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { title: "Siemens part of the product Fixes for code issue vulnerabilities", trust: 0.6, url: "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=228955", }, ], sources: [ { db: "CNNVD", id: "CNNVD-202212-3112", }, ], }, problemtype_data: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { problemtype: "CWE-476", trust: 1, }, { problemtype: "NULL Pointer dereference (CWE-476) [ others ]", trust: 0.8, }, ], sources: [ { db: "JVNDB", id: "JVNDB-2022-023192", }, { db: "NVD", id: "CVE-2022-41280", }, ], }, references: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { trust: 2.4, url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, { trust: 0.8, url: "https://jvn.jp/vu/jvnvu91561630/", }, { trust: 0.8, url: "https://nvd.nist.gov/vuln/detail/cve-2022-41280", }, { trust: 0.8, url: "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-20", }, { trust: 0.6, url: "https://cxsecurity.com/cveshow/cve-2022-41280/", }, ], sources: [ { db: "JVNDB", id: "JVNDB-2022-023192", }, { db: "NVD", id: "CVE-2022-41280", }, { db: "CNNVD", id: "CNNVD-202212-3112", }, ], }, sources: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", data: { "@container": "@list", }, }, data: [ { db: "JVNDB", id: "JVNDB-2022-023192", }, { db: "NVD", id: "CVE-2022-41280", }, { db: "CNNVD", id: "CNNVD-202212-3112", }, ], }, sources_release_date: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", data: { "@container": "@list", }, }, data: [ { date: "2023-11-28T00:00:00", db: "JVNDB", id: "JVNDB-2022-023192", }, { date: "2022-12-13T16:15:22.290000", db: "NVD", id: "CVE-2022-41280", }, { date: "2022-12-13T00:00:00", db: "CNNVD", id: "CNNVD-202212-3112", }, ], }, sources_update_date: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", data: { "@container": "@list", }, }, data: [ { date: "2023-11-28T02:22:00", db: "JVNDB", id: "JVNDB-2022-023192", }, { date: "2023-04-11T10:15:16.757000", db: "NVD", id: "CVE-2022-41280", }, { date: "2023-04-12T00:00:00", db: "CNNVD", id: "CNNVD-202212-3112", }, ], }, threat_type: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: "local", sources: [ { db: "CNNVD", id: "CNNVD-202212-3112", }, ], trust: 0.6, }, title: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: "Siemens' JT2Go and Teamcenter Visualization In NULL Pointer dereference vulnerability", sources: [ { db: "JVNDB", id: "JVNDB-2022-023192", }, ], trust: 0.8, }, type: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: "code problem", sources: [ { db: "CNNVD", id: "CNNVD-202212-3112", }, ], trust: 0.6, }, }
ghsa-frqr-q9vw-43qg
Vulnerability from github
A vulnerability has been identified in JT2Go (All versions), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
{ affected: [], aliases: [ "CVE-2022-41280", ], database_specific: { cwe_ids: [ "CWE-476", ], github_reviewed: false, github_reviewed_at: null, nvd_published_at: "2022-12-13T16:15:00Z", severity: "MODERATE", }, details: "A vulnerability has been identified in JT2Go (All versions), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", id: "GHSA-frqr-q9vw-43qg", modified: "2022-12-15T18:30:17Z", published: "2022-12-13T18:30:33Z", references: [ { type: "ADVISORY", url: "https://nvd.nist.gov/vuln/detail/CVE-2022-41280", }, { type: "WEB", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf", }, ], schema_version: "1.4.0", severity: [ { score: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", type: "CVSS_V3", }, ], }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.