Action not permitted
Modal body text goes here.
cve-2022-43724
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf | Patch, Vendor Advisory |
▼ | Vendor | Product |
---|---|---|
Siemens | SICAM PAS/PQS |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:40:06.447Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM PAS/PQS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.0" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM PAS/PQS (All versions \u003c V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319: Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-13T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-43724", "datePublished": "2022-12-13T00:00:00", "dateReserved": "2022-10-24T00:00:00", "dateUpdated": "2024-08-03T13:40:06.447Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-43724\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-12-13T16:15:24.327\",\"lastModified\":\"2023-10-17T19:01:36.840\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SICAM PAS/PQS (All versions \u003c V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SICAM PAS/PQS (Todas las versiones \u0026lt; V7.0). El software afectado transmite las credenciales de la base de datos para el servidor SQL incorporado en texto plano. En combinaci\u00f3n con la funci\u00f3n xp_cmdshell habilitada de forma predeterminada, atacantes remotos no autenticados podr\u00edan ejecutar comandos personalizados del sistema operativo. En el momento de asignar el CVE, la versi\u00f3n de firmware afectada del componente ya ha sido reemplazada por versiones principales sucesivas.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sicam_pas\\\\/pqs:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.0\",\"matchCriteriaId\":\"8FD90B1C-FD0B-4EA2-9226-3849F7ECFC2F\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
gsd-2022-43724
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-43724", "id": "GSD-2022-43724" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-43724" ], "details": "A vulnerability has been identified in SICAM PAS/PQS (All versions \u003c V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.", "id": "GSD-2022-43724", "modified": "2023-12-13T01:19:31.990051Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-43724", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM PAS/PQS", "version": { "version_data": [ { "version_value": "All versions \u003c V7.0" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM PAS/PQS (All versions \u003c V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-319: Cleartext Transmission of Sensitive Information" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sicam_pas\\/pqs:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-43724" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM PAS/PQS (All versions \u003c V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-319" } ] } ] }, "references": { "reference_data": [ { "name": "N/A", "refsource": "CONFIRM", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2023-10-17T19:01Z", "publishedDate": "2022-12-13T16:15Z" } } }
wid-sec-w-2022-2381
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "hoch" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "Siemens SICAM ist eine Produktfamilie von SCADA-Systemen f\u00fcr den Betrieb von industriellen Prozessen.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein lokaler oder entfernter, anonymer Angreifer kann mehrere Schwachstellen in Siemens SICAM PAS/PQS ausnutzen, um beliebigen Programmcode mit Administratorrechten auszuf\u00fchren und um einen Denial of Service Zustand zu verursachen.", "title": "Angriff" }, { "category": "general", "text": "- Sonstiges", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2022-2381 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2022/wid-sec-w-2022-2381.json" }, { "category": "self", "summary": "WID-SEC-2022-2381 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2022-2381" }, { "category": "external", "summary": "Siemens Security Advisory by Siemens ProductCERT vom 2022-12-20", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf" } ], "source_lang": "en-US", "title": "Siemens SICAM PAS/PQS: Mehrere Schwachstellen", "tracking": { "current_release_date": "2022-12-20T23:00:00.000+00:00", "generator": { "date": "2024-02-15T17:07:33.595+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2022-2381", "initial_release_date": "2022-12-20T23:00:00.000+00:00", "revision_history": [ { "date": "2022-12-20T23:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "Siemens SICAM PAS/PQS \u003c V8.06", "product": { "name": "Siemens SICAM PAS/PQS \u003c V8.06", "product_id": "T025672", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:paspqs__v8.06" } } } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-43724", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens SICAM PAS/PQS. Datenbank-Zugangsdaten f\u00fcr den integrierten SQL-Server werden im Klartext \u00fcbertragen. In Kombination mit der standardm\u00e4\u00dfig aktivierten \"xp_cmdshell\"-Funktion k\u00f6nnen nicht authentifizierte Angreifer benutzerdefinierte Betriebssystembefehle ausf\u00fchren. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich." } ], "product_status": { "known_affected": [ "T025672" ] }, "release_date": "2022-12-20T23:00:00Z", "title": "CVE-2022-43724" }, { "cve": "CVE-2022-43723", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens SICAM PAS/PQS. Die Eingabe bestimmter Parameter in die Bibliothek \"s7ontcp.dll\" wird nicht sachgem\u00e4\u00df validiert. Ein entfernter, anonymer Angreifer kann diese Schwachstelle ausnutzen, um durch das Senden bestimmter Nachrichten die Applikation zum Absturz zu bringen und somit einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T025672" ] }, "release_date": "2022-12-20T23:00:00Z", "title": "CVE-2022-43723" }, { "cve": "CVE-2022-43722", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens SICAM PAS/PQS. Aufgrund einer ungen\u00fcgenden Absicherung eines Ordners, der Bibliotheksdateien enth\u00e4lt, kann ein lokaler Angreifer beliebige b\u00f6sartige DLL Dateien in diesem Ordner ablegen. In der Folge kann er beliebigen Code mit SYSTEM-Rechten zur Ausf\u00fchrung bringen." } ], "product_status": { "known_affected": [ "T025672" ] }, "release_date": "2022-12-20T23:00:00Z", "title": "CVE-2022-43722" } ] }
var-202212-1160
Vulnerability from variot
A vulnerability has been identified in SICAM PAS/PQS (All versions < V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions. Siemens' sicam pas/pqs Contains a vulnerability in the transmission of important information in clear text.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens SICAM PAS/PQS is a software of Siemens company with an operating system for energy automation and power quality
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1160", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sicam pas\\/pqs", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "7.0" }, { "model": "sicam pas/pqs", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sicam pas/pqs", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sicam pas/pqs", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "7.0" }, { "model": "sicam pas/pqs", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v7.0" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-89759" }, { "db": "JVNDB", "id": "JVNDB-2022-023208" }, { "db": "NVD", "id": "CVE-2022-43724" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sicam_pas\\/pqs:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-43724" } ] }, "cve": "CVE-2022-43724", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2022-89759", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-43724", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-43724", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2022-89759", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202212-3099", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-89759" }, { "db": "JVNDB", "id": "JVNDB-2022-023208" }, { "db": "NVD", "id": "CVE-2022-43724" }, { "db": "CNNVD", "id": "CNNVD-202212-3099" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SICAM PAS/PQS (All versions \u003c V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions. Siemens\u0027 sicam pas/pqs Contains a vulnerability in the transmission of important information in clear text.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens SICAM PAS/PQS is a software of Siemens company with an operating system for energy automation and power quality", "sources": [ { "db": "NVD", "id": "CVE-2022-43724" }, { "db": "JVNDB", "id": "JVNDB-2022-023208" }, { "db": "CNVD", "id": "CNVD-2022-89759" }, { "db": "VULHUB", "id": "VHN-440861" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-43724", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-849072", "trust": 3.1 }, { "db": "ICS CERT", "id": "ICSA-22-349-19", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU91561630", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-023208", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-89759", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202212-3099", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-440861", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-89759" }, { "db": "VULHUB", "id": "VHN-440861" }, { "db": "JVNDB", "id": "JVNDB-2022-023208" }, { "db": "NVD", "id": "CVE-2022-43724" }, { "db": "CNNVD", "id": "CNNVD-202212-3099" } ] }, "id": "VAR-202212-1160", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-89759" }, { "db": "VULHUB", "id": "VHN-440861" } ], "trust": 1.2969863 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-89759" } ] }, "last_update_date": "2023-12-18T11:47:07.099000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SICAM PAS/PQS Sensitive Information Plaintext Transmission Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/380771" }, { "title": "Siemens SICAM PAS/PQS Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=217838" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-89759" }, { "db": "CNNVD", "id": "CNNVD-202212-3099" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-319", "trust": 1.1 }, { "problemtype": "Sending important information in clear text (CWE-319) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-440861" }, { "db": "JVNDB", "id": "JVNDB-2022-023208" }, { "db": "NVD", "id": "CVE-2022-43724" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91561630/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-43724" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-19" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-43724/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-89759" }, { "db": "VULHUB", "id": "VHN-440861" }, { "db": "JVNDB", "id": "JVNDB-2022-023208" }, { "db": "NVD", "id": "CVE-2022-43724" }, { "db": "CNNVD", "id": "CNNVD-202212-3099" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-89759" }, { "db": "VULHUB", "id": "VHN-440861" }, { "db": "JVNDB", "id": "JVNDB-2022-023208" }, { "db": "NVD", "id": "CVE-2022-43724" }, { "db": "CNNVD", "id": "CNNVD-202212-3099" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-12-26T00:00:00", "db": "CNVD", "id": "CNVD-2022-89759" }, { "date": "2022-12-13T00:00:00", "db": "VULHUB", "id": "VHN-440861" }, { "date": "2023-11-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-023208" }, { "date": "2022-12-13T16:15:24.327000", "db": "NVD", "id": "CVE-2022-43724" }, { "date": "2022-12-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3099" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-12-26T00:00:00", "db": "CNVD", "id": "CNVD-2022-89759" }, { "date": "2022-12-15T00:00:00", "db": "VULHUB", "id": "VHN-440861" }, { "date": "2023-11-28T03:03:00", "db": "JVNDB", "id": "JVNDB-2022-023208" }, { "date": "2023-10-17T19:01:36.840000", "db": "NVD", "id": "CVE-2022-43724" }, { "date": "2022-12-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3099" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3099" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens\u0027 \u00a0sicam\u00a0pas/pqs\u00a0 Vulnerability in plaintext transmission of important information in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023208" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3099" } ], "trust": 0.6 } }
icsa-22-349-19
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Georgy Zaytsev", "Maxim Kozhevnikov" ], "organization": "Positive Technologies", "summary": "reporting these vulnerabilities to Siemens" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could lead to remote code execution, privilege escalation, or the creation of a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": " Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": " Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": " Munich, Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-849072: Several Vulnerabilities in SICAM PAS before V8.06 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-849072.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-349-19 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-349-19.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-349-19 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-19" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "SSA-849072: Several Vulnerabilities in SICAM PAS before V8.06 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf" }, { "category": "external", "summary": "SSA-849072: Several Vulnerabilities in SICAM PAS before V8.06 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-849072.txt" } ], "title": "Siemens SICAM PAS", "tracking": { "current_release_date": "2022-12-15T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-349-19", "initial_release_date": "2022-12-15T00:00:00.000000Z", "revision_history": [ { "date": "2022-12-15T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V7.0", "product": { "name": "SICAM PAS/PQS", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "\u003e= 7.0 \u003c V8.06", "product": { "name": "SICAM PAS/PQS", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SICAM PAS/PQS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-43722", "cwe": { "id": "CWE-427", "name": "Uncontrolled Search Path Element" }, "notes": [ { "category": "summary", "text": "Affected software does not properly secure a folder containing library files. This could allow an attacker to place a custom malicious DLL in this folder which is then run with SYSTEM rights when a service is started that requires this DLL.\r\nAt the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-43722" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109744496/" }, { "category": "mitigation", "details": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design.\n\nSiemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. \n\nAs a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.\n\nRecommended security guidelines can be found at:\n\n\nhttps://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-43722" }, { "cve": "CVE-2022-43723", "cwe": { "id": "CWE-1287", "name": "Improper Validation of Specified Type of Input" }, "notes": [ { "category": "summary", "text": "Affected software does not properly validate the input for a certain parameter in the s7ontcp.dll. This could allow an unauthenticated remote attacker to send messages and create a denial of service condition as the application crashes.\r\nAt the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-43723" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109744496/" }, { "category": "vendor_fix", "details": "Update to V8.06 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109744493/" }, { "category": "mitigation", "details": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design.\n\nSiemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. \n\nAs a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.\n\nRecommended security guidelines can be found at:\n\n\nhttps://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2022-43723" }, { "cve": "CVE-2022-43724", "cwe": { "id": "CWE-319", "name": "Cleartext Transmission of Sensitive Information" }, "notes": [ { "category": "summary", "text": "Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands.\r\nAt the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-43724" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.0 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109744496/" }, { "category": "mitigation", "details": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design.\n\nSiemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. \n\nAs a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.\n\nRecommended security guidelines can be found at:\n\n\nhttps://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-43724" } ] }
ghsa-gpf3-4fw6-p76w
Vulnerability from github
A vulnerability has been identified in SICAM PAS/PQS (All versions < V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.
{ "affected": [], "aliases": [ "CVE-2022-43724" ], "database_specific": { "cwe_ids": [ "CWE-319" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-12-13T16:15:00Z", "severity": "CRITICAL" }, "details": "A vulnerability has been identified in SICAM PAS/PQS (All versions \u003c V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.", "id": "GHSA-gpf3-4fw6-p76w", "modified": "2022-12-15T21:30:28Z", "published": "2022-12-13T18:30:26Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-43724" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-849072.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.