cve-2022-46141
Vulnerability from cvelistv5
Published
2023-12-12 11:25
Modified
2024-11-25 21:17
Summary
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.
Impacted products
Vendor Product Version
Siemens SIMATIC STEP 7 (TIA Portal) Version: All versions < V19
Create a notification for this product.
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-03T14:24:03.267Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf",
               },
            ],
            title: "CVE Program Container",
         },
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2022-46141",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "partial",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-11-25T21:17:05.789021Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-11-25T21:17:26.263Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "SIMATIC STEP 7 (TIA Portal)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V19",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 4.2,
                  baseSeverity: "MEDIUM",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
                  version: "3.1",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-316",
                     description: "CWE-316: Cleartext Storage of Sensitive Information in Memory",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-12-12T11:25:26.583Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2022-46141",
      datePublished: "2023-12-12T11:25:26.583Z",
      dateReserved: "2022-11-28T16:50:58.483Z",
      dateUpdated: "2024-11-25T21:17:26.263Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      fkie_nvd: {
         configurations: "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"19\", \"matchCriteriaId\": \"F77226E4-F3B3-4D3B-B944-17CED48BD73A\"}]}]}]",
         descriptions: "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Portal) (todas las versiones &lt; V19). Una vulnerabilidad de divulgaci\\u00f3n de informaci\\u00f3n podr\\u00eda permitir a un atacante local obtener acceso a la contrase\\u00f1a de nivel de acceso de las CPU SIMATIC S7-1200 y S7-1500, cuando la ingresa un usuario leg\\u00edtimo en la configuraci\\u00f3n de hardware de la aplicaci\\u00f3n afectada.\"}]",
         id: "CVE-2022-46141",
         lastModified: "2024-11-21T07:30:10.817",
         metrics: "{\"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N\", \"baseScore\": 4.2, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 0.6, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}]}",
         published: "2023-12-12T12:15:10.003",
         references: "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
         sourceIdentifier: "productcert@siemens.com",
         vulnStatus: "Modified",
         weaknesses: "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-316\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-312\"}]}]",
      },
      nvd: "{\"cve\":{\"id\":\"CVE-2022-46141\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-12-12T12:15:10.003\",\"lastModified\":\"2024-11-21T07:30:10.817\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Portal) (todas las versiones &lt; V19). Una vulnerabilidad de divulgación de información podría permitir a un atacante local obtener acceso a la contraseña de nivel de acceso de las CPU SIMATIC S7-1200 y S7-1500, cuando la ingresa un usuario legítimo en la configuración de hardware de la aplicación afectada.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N\",\"baseScore\":4.2,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.6,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-316\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"19\",\"matchCriteriaId\":\"F77226E4-F3B3-4D3B-B944-17CED48BD73A\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
      vulnrichment: {
         containers: "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T14:24:03.267Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-46141\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-25T21:17:05.789021Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-25T21:17:17.093Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 4.2, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SIMATIC STEP 7 (TIA Portal)\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions < V19\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-316\", \"description\": \"CWE-316: Cleartext Storage of Sensitive Information in Memory\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2023-12-12T11:25:26.583Z\"}}}",
         cveMetadata: "{\"cveId\": \"CVE-2022-46141\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-25T21:17:26.263Z\", \"dateReserved\": \"2022-11-28T16:50:58.483Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2023-12-12T11:25:26.583Z\", \"assignerShortName\": \"siemens\"}",
         dataType: "CVE_RECORD",
         dataVersion: "5.1",
      },
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.