cve-2023-1618
Vulnerability from cvelistv5
Published
2023-05-19 04:19
Modified
2024-08-02 05:57
Summary
Authentication Bypass Vulnerability in MELSEC WS Series Ethernet Interface Module
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:57:24.442Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-002_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU96063959"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-138-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC WS Series WS0-GETH00200",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Serial number 2310 **** and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Active Debug Code vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 Serial number 2310 **** and prior allows a remote unauthenticated attacker to bypass authentication and illegally log into the affected module by connecting to it via telnet which is hidden function and is enabled by default when shipped from the factory. As a result, a remote attacker with unauthorized login can reset the module, and if certain conditions are met, he/she can disclose or tamper with the module\u0027s configuration or rewrite the firmware."
            }
          ],
          "value": "Active Debug Code vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 Serial number 2310 **** and prior allows a remote unauthenticated attacker to bypass authentication and illegally log into the affected module by connecting to it via telnet which is hidden function and is enabled by default when shipped from the factory. As a result, a remote attacker with unauthorized login can reset the module, and if certain conditions are met, he/she can disclose or tamper with the module\u0027s configuration or rewrite the firmware."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489 Active Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-23T00:20:36.551Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-002_en.pdf"
        },
        {
          "url": "https://jvn.jp/vu/JVNVU96063959"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-138-02"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Authentication Bypass Vulnerability in MELSEC WS Series Ethernet Interface Module",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-1618",
    "datePublished": "2023-05-19T04:19:42.944Z",
    "dateReserved": "2023-03-24T08:06:05.810Z",
    "dateUpdated": "2024-08-02T05:57:24.442Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-1618\",\"sourceIdentifier\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"published\":\"2023-05-19T05:15:20.350\",\"lastModified\":\"2023-08-23T01:15:09.957\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Active Debug Code vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 Serial number 2310 **** and prior allows a remote unauthenticated attacker to bypass authentication and illegally log into the affected module by connecting to it via telnet which is hidden function and is enabled by default when shipped from the factory. As a result, a remote attacker with unauthorized login can reset the module, and if certain conditions are met, he/she can disclose or tamper with the module\u0027s configuration or rewrite the firmware.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\",\"baseScore\":8.6,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":4.7},{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1188\"}]},{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-489\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:melsec_ws0-geth00200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2309DB7C-07CA-4821-A7A2-F461652E62C8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:melsec_ws0-geth00200_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5BE5176E-49E3-48EF-9E05-DFE39E9AE6BB\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/vu/JVNVU96063959\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-138-02\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-002_en.pdf\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.