cve-2023-1935
Vulnerability from cvelistv5
Published
2023-08-02 22:40
Modified
2024-10-21 18:57
Severity ?
Summary
CVE-2023-1935
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/news-events/ics-advisories/icsa-23-206-03Third Party Advisory, US Government Resource
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:05:26.782Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-206-03"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-1935",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-21T18:57:37.798124Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-21T18:57:56.089Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DL8000",
          "vendor": "Emerson Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "ROC827",
          "vendor": "Emerson Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "ROC809L",
          "vendor": "Emerson Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "ROC827",
          "vendor": "Emerson Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "ROC809",
          "vendor": "Emerson Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "ROC800-Series RTU devices are vulnerable to an authentication bypass, which could allow an attacker to gain unauthorized access to data or control of the device and cause a denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-305",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-02T22:40:46.883Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-206-03"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-1935",
      "x_generator": {
        "engine": "VINCE 2.1.3",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-1935"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-1935",
    "datePublished": "2023-08-02T22:40:46.883Z",
    "dateReserved": "2023-04-07T00:02:59.470Z",
    "dateUpdated": "2024-10-21T18:57:56.089Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-1935\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2023-08-02T23:15:10.293\",\"lastModified\":\"2023-11-07T04:05:26.163\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"ROC800-Series RTU devices are vulnerable to an authentication bypass, which could allow an attacker to gain unauthorized access to data or control of the device and cause a denial-of-service condition.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.4,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.5},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.4,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.5}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:emerson:roc809_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18077D47-9CE0-43BB-AEF2-C36B860068F4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:emerson:roc809:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D7BF172-D25F-4FA4-9F3D-076054DC2B6B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:emerson:roc827_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18ED69F7-497D-46F7-8658-E896BB97FE0E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:emerson:roc827:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF43B58B-549D-49AC-A6CD-D56A51D514E4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:emerson:roc809l_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FC76BA18-6D73-4DF8-99F9-3746874B87CE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:emerson:roc809l:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1E166C44-92E0-4FF1-8E72-926B3DBFD685\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:emerson:roc827l_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"025DE80C-CF6E-454E-B031-872BA0316ADE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:emerson:roc827l:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6BC649A2-40AE-439F-AD70-70ADB3E8BC11\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:emerson:dl8000_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DAF643AE-8D62-41EE-AEB5-414094F299E3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:emerson:dl8000:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C771FBBB-0FEA-4BE4-A251-58C9EBD07E12\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-206-03\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.