cve-2023-22324
Vulnerability from cvelistv5
Published
2023-01-30 00:00
Modified
2024-08-02 10:07
Severity ?
EPSS score ?
Summary
SQL injection vulnerability in the CONPROSYS HMI System (CHS) Ver.3.5.0 and earlier allows a remote authenticated attacker to execute an arbitrary SQL command. As a result, information stored in the database may be obtained.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Contec Co., Ltd. | CONPROSYS HMI System (CHS) |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T10:07:06.179Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b" }, { "tags": [ "x_transferred" ], "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230124_en.pdf" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/en/vu/JVNVU97195023/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CONPROSYS HMI System (CHS)", "vendor": "Contec Co., Ltd.", "versions": [ { "status": "affected", "version": "Ver.3.5.0 and earlier" } ] } ], "descriptions": [ { "lang": "en", "value": "SQL injection vulnerability in the CONPROSYS HMI System (CHS) Ver.3.5.0 and earlier allows a remote authenticated attacker to execute an arbitrary SQL command. As a result, information stored in the database may be obtained." } ], "problemTypes": [ { "descriptions": [ { "description": "SQL Injection", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-01-30T00:00:00", "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "shortName": "jpcert" }, "references": [ { "url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b" }, { "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230124_en.pdf" }, { "url": "https://jvn.jp/en/vu/JVNVU97195023/" } ] } }, "cveMetadata": { "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "assignerShortName": "jpcert", "cveId": "CVE-2023-22324", "datePublished": "2023-01-30T00:00:00", "dateReserved": "2022-12-28T00:00:00", "dateUpdated": "2024-08-02T10:07:06.179Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-22324\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2023-01-30T07:15:09.767\",\"lastModified\":\"2023-02-06T19:55:03.167\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"SQL injection vulnerability in the CONPROSYS HMI System (CHS) Ver.3.5.0 and earlier allows a remote authenticated attacker to execute an arbitrary SQL command. As a result, information stored in the database may be obtained.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de inyecci\u00f3n SQL en CONPROSYS HMI System (CHS) Ver.3.5.0 y anteriores permite que un atacante remoto autenticado ejecute un comando SQL arbitrario. Como resultado, se puede obtener informaci\u00f3n almacenada en la base de datos.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.1\",\"matchCriteriaId\":\"5CD57955-96C3-4807-8BA1-0DAC528D345C\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/en/vu/JVNVU97195023/\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230124_en.pdf\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.