cve-2023-27465
Vulnerability from cvelistv5
Published
2023-06-13 08:17
Modified
2024-08-02 12:09
Summary
A vulnerability has been identified in SIMOTION C240 (All versions >= V5.4 < V5.5 SP1), SIMOTION C240 PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D445-2 DP/PN (All versions >= V5.4), SIMOTION D445-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D455-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION P320-4 E (All versions >= V5.4), SIMOTION P320-4 S (All versions >= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:09:43.410Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION C240",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION C240 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D410-2 DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D410-2 DP/PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D425-2 DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D425-2 DP/PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D435-2 DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D435-2 DP/PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D445-2 DP/PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D445-2 DP/PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D455-2 DP/PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION P320-4 E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION P320-4 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMOTION C240 (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION C240 PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D410-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D410-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D425-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D425-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D435-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D435-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D445-2 DP/PN (All versions \u003e= V5.4), SIMOTION D445-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D455-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION P320-4 E (All versions \u003e= V5.4), SIMOTION P320-4 S (All versions \u003e= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-213",
              "description": "CWE-213: Exposure of Sensitive Information Due to Incompatible Policies",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-13T08:17:06.765Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-27465",
    "datePublished": "2023-06-13T08:17:06.765Z",
    "dateReserved": "2023-03-01T17:29:31.289Z",
    "dateUpdated": "2024-08-02T12:09:43.410Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-27465\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-06-13T09:15:16.557\",\"lastModified\":\"2023-07-05T17:48:25.550\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMOTION C240 (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION C240 PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D410-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D410-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D425-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D425-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D435-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D435-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D445-2 DP/PN (All versions \u003e= V5.4), SIMOTION D445-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D455-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION P320-4 E (All versions \u003e= V5.4), SIMOTION P320-4 S (All versions \u003e= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.6,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.9,\"impactScore\":3.6},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.6,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-213\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_d425-2_dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFD83F3F-CF11-44D9-8F9C-0B8D33BC3481\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d425-2_dp_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.5\",\"matchCriteriaId\":\"0A65B54E-FE29-4352-8BA4-60C2F23F87F8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d425-2_dp_firmware:5.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"B6979F0F-FA12-422F-938D-0C84D39F69E9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_d425-2_dp\\\\/pn:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1A007F9C-B6E3-4606-A7C2-B78E5F51C9BF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d425-2_dp\\\\/pn_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.5\",\"matchCriteriaId\":\"50C77E0A-9C5D-43EA-9157-C94CF4ACBE98\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d425-2_dp\\\\/pn_firmware:5.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"35BA3146-E138-48C5-BAFB-36FF795C8591\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d435-2_dp_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.5\",\"matchCriteriaId\":\"848DE61E-A4F9-4368-82AB-EA6FCD369EDB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d435-2_dp_firmware:5.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC2302CA-AD84-4FE8-98EA-7764A5B8978B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_d435-2_dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"80932D46-6182-4B9D-9A66-BC381052DBF8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d435-2_dp\\\\/pn_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.5\",\"matchCriteriaId\":\"FE2ACB98-373C-471C-B5A7-8D1BE59BBDA7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d435-2_dp\\\\/pn_firmware:5.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"AB781258-8A47-4388-A115-68ACF6CFD420\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_d435-2_dp\\\\/pn:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3371CB24-AB41-44C7-93B7-78E2BD171D42\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d445-2_dp\\\\/pn_\\\\(0aa1\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.5\",\"matchCriteriaId\":\"B9B8C9F9-9474-4153-8CCA-60308E13543D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d445-2_dp\\\\/pn_\\\\(0aa1\\\\)_firmware:5.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"117C8E63-C09D-412C-9B68-F2C72A8CCEDD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_d445-2_dp\\\\/pn_\\\\(0aa1\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DC9044F0-7E54-4C66-8613-A440B71D9D0D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d445-2_dp\\\\/pn_\\\\(0aa0\\\\)_firmware:5.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6B9D8FBD-E8E7-43E1-922F-973851E0D160\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_d445-2_dp\\\\/pn_\\\\(0aa0\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"05D488BB-E0B5-46DF-B303-98524A39EEC2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d455-2_dp\\\\/pn_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.5\",\"matchCriteriaId\":\"9CB06BE4-AA5C-4367-B34F-BB3FC17B9470\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d455-2_dp\\\\/pn_firmware:5.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"995B8740-C501-4448-9D22-4D115FAAE543\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_d455-2_dp\\\\/pn:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"53FBAAA1-4012-463D-864B-C7BEAE15093E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_p320-4_e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"80DFB571-E3FA-44AA-B81C-AC7E13FFCB01\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_p320-4_e_firmware:5.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2C90B0F9-BBC8-417E-98FD-30BC069E769D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_p320-4_s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4849FE93-67D0-496F-B47D-5035FF902540\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_p320-4_s_firmware:5.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D49AFE41-D93E-4488-A5CB-AC48BB5921D6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_d410-2_dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2899391-D29A-4C95-A795-1B7EADCDF799\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d410-2_dp_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.5\",\"matchCriteriaId\":\"91C51B40-4344-4796-AF7B-9F85D255A113\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d410-2_dp_firmware:5.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"E2E25B36-BB4D-40B6-91A2-FC344E063B45\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_d410-2_dp\\\\/pn:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C6C5013B-BE8F-4635-9F7E-006EE737A4A0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d410-2_dp\\\\/pn_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.5\",\"matchCriteriaId\":\"52950381-7B46-46F7-9B44-0313EA47EA87\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_d410-2_dp\\\\/pn_firmware:5.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"BFA771D3-A08F-4690-853D-F07B47EC83AE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_c240_pn:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2355A13D-6E84-4F35-8BE6-223C086E3719\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_c240_pn_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.5\",\"matchCriteriaId\":\"625A4A2B-37BB-4534-B1DD-3B18862F97BC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_c240_pn_firmware:5.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"2BE0D94D-FFF4-4913-9376-A3389579CC70\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simotion_c240:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"48B461ED-4B04-4EC2-B88E-F50D53509B1D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_c240_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.5\",\"matchCriteriaId\":\"94035BD3-584A-4F93-A9AB-75A32F1628E2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simotion_c240_firmware:5.5:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"6E8FF00E-5125-4CD8-BD83-9F595ABA3B11\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.