cve-2023-27920
Vulnerability from cvelistv5
Published
2023-05-23 00:00
Modified
2024-08-02 12:23
Severity ?
EPSS score ?
Summary
Improper access control vulnerability in the system date/time setting page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to alter system date/time of the affected product.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Contec Co., Ltd. | SolarView Compact |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:23:30.630Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.contec.com/jp/download/donwload-list/?itemid=b28c8b7c-9f40-40b2-843c-b5b04c035b0e#firmware" }, { "tags": [ "x_transferred" ], "url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_solarview_230508.pdf" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/en/vu/JVNVU92106300/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SolarView Compact", "vendor": "Contec Co., Ltd.", "versions": [ { "status": "affected", "version": "SV-CPT-MC310 versions prior to Ver.8.10, and SV-CPT-MC310F versions prior to Ver.8.10" } ] } ], "descriptions": [ { "lang": "en", "value": "Improper access control vulnerability in the system date/time setting page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to alter system date/time of the affected product." } ], "problemTypes": [ { "descriptions": [ { "description": "Improper access control", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-23T00:00:00", "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "shortName": "jpcert" }, "references": [ { "url": "https://www.contec.com/jp/download/donwload-list/?itemid=b28c8b7c-9f40-40b2-843c-b5b04c035b0e#firmware" }, { "url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_solarview_230508.pdf" }, { "url": "https://jvn.jp/en/vu/JVNVU92106300/" } ] } }, "cveMetadata": { "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "assignerShortName": "jpcert", "cveId": "CVE-2023-27920", "datePublished": "2023-05-23T00:00:00", "dateReserved": "2023-03-15T00:00:00", "dateUpdated": "2024-08-02T12:23:30.630Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-27920\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2023-05-23T02:15:09.827\",\"lastModified\":\"2023-05-30T15:41:23.137\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper access control vulnerability in the system date/time setting page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to alter system date/time of the affected product.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:contec:sv-cpt-mc310f_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.10\",\"matchCriteriaId\":\"825C8DE5-2210-4274-81EE-E57DD13F74F7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:contec:sv-cpt-mc310f:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CAC9BA1B-C65A-4EEA-AAD6-88685BC7A4FA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:contec:sv-cpt-mc310_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.10\",\"matchCriteriaId\":\"DC74EAB1-C008-4DD5-AF3B-78F6171799DE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:contec:sv-cpt-mc310:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F9FCCA5E-19F8-47D9-A6C6-77AF2AEFD51A\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/en/vu/JVNVU92106300/\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_solarview_230508.pdf\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.contec.com/jp/download/donwload-list/?itemid=b28c8b7c-9f40-40b2-843c-b5b04c035b0e#firmware\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.