CVE-2023-41372 (GCVE-0-2023-41372)

Vulnerability from cvelistv5 – Published: 2023-10-25 14:13 – Updated: 2024-09-12 14:28
VLAI?
Summary
The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:01:35.280Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ctrlx_hmi_web_panel_wr2107",
            "vendor": "boschrexroth",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ctrlx_hmi_web_panel_wr2110",
            "vendor": "boschrexroth",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ctrlx_hmi_web_panel_wr2115",
            "vendor": "boschrexroth",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-41372",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-10T18:51:52.995688Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-12T14:28:34.281Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ctrlX HMI Web Panel - WR21 (WR2107)",
          "vendor": "Rexroth",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "product": "ctrlX HMI Web Panel - WR21 (WR2110)",
          "vendor": "Rexroth",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "product": "ctrlX HMI Web Panel - WR21 (WR2115)",
          "vendor": "Rexroth",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en-US"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-25T14:13:34.827Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2023-41372",
    "datePublished": "2023-10-25T14:13:34.827Z",
    "dateReserved": "2023-10-18T09:35:22.507Z",
    "dateUpdated": "2024-09-12T14:28:34.281Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7FFA1309-DBEE-46F1-B6FD-DAE896180411\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"87C129B8-F100-4D3A-97BC-BAD9A4129F9D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FD47D2E3-F53F-4CE8-BEF7-76F78AEBAF5C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"326E80AA-C9B4-4BF1-AA2B-98A3802A72C9\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4CA92486-EEBE-42FD-9755-006B7F2DF361\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"167C9BC4-FCC5-4FAF-8F75-F967C77400A7\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair\"}, {\"lang\": \"es\", \"value\": \"La vulnerabilidad permite que una aplicaci\\u00f3n de terceros sin privilegios (no confiable) modifique arbitrariamente la configuraci\\u00f3n del servidor de la aplicaci\\u00f3n cliente de Android, induci\\u00e9ndola a conectarse a un servidor malicioso controlado por un atacante. Esto es posible falsificando una intenci\\u00f3n de transmisi\\u00f3n v\\u00e1lida cifrada con un par de claves RSA codificadas\"}]",
      "id": "CVE-2023-41372",
      "lastModified": "2024-11-21T08:21:10.570",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"psirt@bosch.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}]}",
      "published": "2023-10-25T18:17:30.917",
      "references": "[{\"url\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html\", \"source\": \"psirt@bosch.com\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "psirt@bosch.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"psirt@bosch.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-798\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-798\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-41372\",\"sourceIdentifier\":\"psirt@bosch.com\",\"published\":\"2023-10-25T18:17:30.917\",\"lastModified\":\"2024-11-21T08:21:10.570\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair\"},{\"lang\":\"es\",\"value\":\"La vulnerabilidad permite que una aplicaci\u00f3n de terceros sin privilegios (no confiable) modifique arbitrariamente la configuraci\u00f3n del servidor de la aplicaci\u00f3n cliente de Android, induci\u00e9ndola a conectarse a un servidor malicioso controlado por un atacante. Esto es posible falsificando una intenci\u00f3n de transmisi\u00f3n v\u00e1lida cifrada con un par de claves RSA codificadas\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7FFA1309-DBEE-46F1-B6FD-DAE896180411\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"87C129B8-F100-4D3A-97BC-BAD9A4129F9D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FD47D2E3-F53F-4CE8-BEF7-76F78AEBAF5C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"326E80AA-C9B4-4BF1-AA2B-98A3802A72C9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4CA92486-EEBE-42FD-9755-006B7F2DF361\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"167C9BC4-FCC5-4FAF-8F75-F967C77400A7\"}]}]}],\"references\":[{\"url\":\"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html\",\"source\":\"psirt@bosch.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"cna\": {\"providerMetadata\": {\"orgId\": \"c95f66b2-7e7c-41c5-8f09-6f86ec68659c\", \"shortName\": \"bosch\", \"dateUpdated\": \"2023-10-25T14:13:34.827Z\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair\"}], \"affected\": [{\"vendor\": \"Rexroth\", \"product\": \"ctrlX HMI Web Panel - WR21 (WR2107)\", \"versions\": [{\"version\": \"all\", \"status\": \"affected\"}]}, {\"vendor\": \"Rexroth\", \"product\": \"ctrlX HMI Web Panel - WR21 (WR2110)\", \"versions\": [{\"version\": \"all\", \"status\": \"affected\"}]}, {\"vendor\": \"Rexroth\", \"product\": \"ctrlX HMI Web Panel - WR21 (WR2115)\", \"versions\": [{\"version\": \"all\", \"status\": \"affected\"}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en-US\", \"description\": \"CWE-798 Use of Hard-coded Credentials\", \"cweId\": \"CWE-798\"}]}], \"references\": [{\"url\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html\", \"name\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html\", \"tags\": [\"vendor-advisory\"]}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\"}}]}, \"adp\": [{\"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T19:01:35.280Z\"}, \"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html\", \"name\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}]}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-41372\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-10T18:51:52.995688Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*\"], \"vendor\": \"boschrexroth\", \"product\": \"ctrlx_hmi_web_panel_wr2107\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*\"], \"vendor\": \"boschrexroth\", \"product\": \"ctrlx_hmi_web_panel_wr2110\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*\"], \"vendor\": \"boschrexroth\", \"product\": \"ctrlx_hmi_web_panel_wr2115\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-10T18:54:42.035Z\"}}]}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-41372\", \"assignerOrgId\": \"c95f66b2-7e7c-41c5-8f09-6f86ec68659c\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"bosch\", \"dateReserved\": \"2023-10-18T09:35:22.507Z\", \"datePublished\": \"2023-10-25T14:13:34.827Z\", \"dateUpdated\": \"2024-09-12T14:28:34.281Z\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…