cve-2023-44315
Vulnerability from cvelistv5
Published
2023-10-10 10:21
Modified
2024-08-02 19:59
Summary
A vulnerability has been identified in SINEC NMS (All versions < V2.0). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could prepare a stored cross-site scripting (XSS) attack that may lead to unintentional modification of application data by legitimate users.
Impacted products
VendorProduct
SiemensSINEC NMS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:59:52.165Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160243.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-160243.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SINEC NMS (All versions \u003c V2.0). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could prepare a stored cross-site scripting (XSS) attack that may lead to unintentional modification of application data by legitimate users."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:04:29.466Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160243.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-160243.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-44315",
    "datePublished": "2023-10-10T10:21:41.852Z",
    "dateReserved": "2023-09-28T13:54:53.927Z",
    "dateUpdated": "2024-08-02T19:59:52.165Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-44315\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-10-10T11:15:12.993\",\"lastModified\":\"2024-07-09T12:15:09.857\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEC NMS (All versions \u003c V2.0). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could prepare a stored cross-site scripting (XSS) attack that may lead to unintentional modification of application data by legitimate users.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones \u0026lt; V2.0). La aplicaci\u00f3n afectada sanitiza incorrectamente ciertos datos de configuraci\u00f3n SNMP recuperados de los dispositivos monitorizados. Un atacante con acceso a un dispositivo monitorizado podr\u00eda preparar un ataque de Cross-Site Scripting (XSS) almacenado que puede llevar a la modificaci\u00f3n no intencionada de los datos de la aplicaci\u00f3n por parte de usuarios leg\u00edtimos.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.7,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.6,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.0\",\"matchCriteriaId\":\"A7F0A543-38E1-48B9-A984-259081E49EAA\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-160243.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-160243.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}