Action not permitted
Modal body text goes here.
cve-2023-48429
Vulnerability from cvelistv5
Published
2023-12-12 11:27
Modified
2024-08-02 21:30
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf | Patch, Vendor Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:30:35.075Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SINEC INS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP2 Update 2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart." } ], "metrics": [ { "cvssV3_1": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-394", "description": "CWE-394: Unexpected Status Code or Return Value", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-12T11:27:20.840Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-48429", "datePublished": "2023-12-12T11:27:20.840Z", "dateReserved": "2023-11-16T16:30:40.849Z", "dateUpdated": "2024-08-02T21:30:35.075Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-48429\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-12-12T12:15:15.083\",\"lastModified\":\"2023-12-14T19:37:51.017\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEC INS (Todas las versiones \u0026lt; V1.0 SP2 Update 2). La interfaz de usuario web de los dispositivos afectados no comprueba la longitud de los par\u00e1metros en determinadas condiciones. Esto permite que un administrador malintencionado bloquee el servidor enviando una solicitud manipulada al servidor. El servidor se reiniciar\u00e1 autom\u00e1ticamente.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\",\"baseScore\":2.7,\"baseSeverity\":\"LOW\"},\"exploitabilityScore\":1.2,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-394\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0\",\"matchCriteriaId\":\"C89891C1-DFD7-4E1F-80A9-7485D86A15B5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4664B195-AF14-4834-82B3-0B2C98020EB6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"75BC588E-CDF0-404E-AD61-02093A1DF343\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"A334F7B4-7283-4453-BAED-D2E01B7F8A6E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*\",\"matchCriteriaId\":\"A6BEA71C-CA81-4B5D-A688-2B21E62DC351\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
ghsa-hf2c-2hx8-m89f
Vulnerability from github
Published
2023-12-12 12:30
Modified
2023-12-12 12:30
Severity ?
Details
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.
{ "affected": [], "aliases": [ "CVE-2023-48429" ], "database_specific": { "cwe_ids": [ "CWE-394", "CWE-754" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2023-12-12T12:15:15Z", "severity": "LOW" }, "details": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.", "id": "GHSA-hf2c-2hx8-m89f", "modified": "2023-12-12T12:30:54Z", "published": "2023-12-12T12:30:54Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-48429" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L", "type": "CVSS_V3" } ] }
icsa-23-348-16
Vulnerability from csaf_cisa
Published
2023-12-12 00:00
Modified
2023-12-12 00:00
Summary
Siemens SINEC INS
Notes
Summary
SINEC INS before V1.0 SP2 Update 2 is affected by multiple vulnerabilities.
Siemens has released an update for SINEC INS and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEC INS before V1.0 SP2 Update 2 is affected by multiple vulnerabilities.\n\nSiemens has released an update for SINEC INS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-077170: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 2 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-077170.json" }, { "category": "self", "summary": "SSA-077170: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 2 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-077170.html" }, { "category": "self", "summary": "SSA-077170: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 2 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf" }, { "category": "self", "summary": "SSA-077170: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 2 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-077170.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-348-16 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-348-16.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-348-16 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-16" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SINEC INS", "tracking": { "current_release_date": "2023-12-12T00:00:00Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-348-16", "initial_release_date": "2023-12-12T00:00:00Z", "revision_history": [ { "date": "2023-12-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.0 SP2 Update 2", "product": { "name": "SINEC INS", "product_id": "1" } } ], "category": "product_name", "name": "SINEC INS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-0464", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "A security vulnerability has been identified in all supported versions of OpenSSL related to the verification of X.509 certificate chains that include policy constraints. Attackers may be able to exploit this vulnerability by creating a malicious certificate chain that triggers exponential use of computational resources, leading to a denial-of-service (DoS) attack on affected systems.\r\n\r\nPolicy processing is disabled by default but can be enabled by passing the `-policy` argument to the command line utilities or by calling the `X509_VERIFY_PARAM_set1_policies()` function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-0464" }, { "cve": "CVE-2023-27538", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "libcurl would reuse a previously created connection even when an SSH related option had been changed that should have prohibited reuse. libcurl keeps previously used connections in a connection pool for subsequent transfers to reuse if one of them matches the setup. However, two SSH settings were left out from the configuration match checks, making them match too easily.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-27538" }, { "cve": "CVE-2023-48427", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "Affected products do not properly validate the certificate of the configured UMC server. This could allow an attacker to intercept credentials that are sent to the UMC server as well as to manipulate responses, potentially allowing an attacker to escalate privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-48427" }, { "cve": "CVE-2023-48428", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The radius configuration mechanism of affected products does not correctly check uploaded certificates. A malicious admin could upload a crafted certificate resulting in a denial-of-service condition or potentially issue commands on system level.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-48428" }, { "cve": "CVE-2023-48429", "cwe": { "id": "CWE-394", "name": "Unexpected Status Code or Return Value" }, "notes": [ { "category": "summary", "text": "The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-48429" }, { "cve": "CVE-2023-48430", "cwe": { "id": "CWE-392", "name": "Missing Report of Error Condition" }, "notes": [ { "category": "summary", "text": "The REST API of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the API. The server will automatically restart.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-48430" }, { "cve": "CVE-2023-48431", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Affected software does not correctly validate the response received by an UMC server. An attacker can use this to crash the affected software by providing and configuring a malicious UMC server or by manipulating the traffic from a legitimate UMC server (i.e. leveraging CVE-2023-48427).", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-48431" } ] }
ssa-077170
Vulnerability from csaf_siemens
Published
2023-12-12 00:00
Modified
2023-12-12 00:00
Summary
SSA-077170: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 2
Notes
Summary
SINEC INS before V1.0 SP2 Update 2 is affected by multiple vulnerabilities.
Siemens has released an update for SINEC INS and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEC INS before V1.0 SP2 Update 2 is affected by multiple vulnerabilities.\n\nSiemens has released an update for SINEC INS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-077170: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 2 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-077170.html" }, { "category": "self", "summary": "SSA-077170: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 2 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-077170.json" }, { "category": "self", "summary": "SSA-077170: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 2 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf" }, { "category": "self", "summary": "SSA-077170: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 2 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-077170.txt" } ], "title": "SSA-077170: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 2", "tracking": { "current_release_date": "2023-12-12T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-077170", "initial_release_date": "2023-12-12T00:00:00Z", "revision_history": [ { "date": "2023-12-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.0 SP2 Update 2", "product": { "name": "SINEC INS", "product_id": "1" } } ], "category": "product_name", "name": "SINEC INS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-0464", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "A security vulnerability has been identified in all supported versions of OpenSSL related to the verification of X.509 certificate chains that include policy constraints. Attackers may be able to exploit this vulnerability by creating a malicious certificate chain that triggers exponential use of computational resources, leading to a denial-of-service (DoS) attack on affected systems.\r\n\r\nPolicy processing is disabled by default but can be enabled by passing the `-policy` argument to the command line utilities or by calling the `X509_VERIFY_PARAM_set1_policies()` function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-0464" }, { "cve": "CVE-2023-27538", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "libcurl would reuse a previously created connection even when an SSH related option had been changed that should have prohibited reuse. libcurl keeps previously used connections in a connection pool for subsequent transfers to reuse if one of them matches the setup. However, two SSH settings were left out from the configuration match checks, making them match too easily.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-27538" }, { "cve": "CVE-2023-48427", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "Affected products do not properly validate the certificate of the configured UMC server. This could allow an attacker to intercept credentials that are sent to the UMC server as well as to manipulate responses, potentially allowing an attacker to escalate privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-48427" }, { "cve": "CVE-2023-48428", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The radius configuration mechanism of affected products does not correctly check uploaded certificates. A malicious admin could upload a crafted certificate resulting in a denial-of-service condition or potentially issue commands on system level.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-48428" }, { "cve": "CVE-2023-48429", "cwe": { "id": "CWE-394", "name": "Unexpected Status Code or Return Value" }, "notes": [ { "category": "summary", "text": "The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-48429" }, { "cve": "CVE-2023-48430", "cwe": { "id": "CWE-392", "name": "Missing Report of Error Condition" }, "notes": [ { "category": "summary", "text": "The REST API of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the API. The server will automatically restart.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-48430" }, { "cve": "CVE-2023-48431", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Affected software does not correctly validate the response received by an UMC server. An attacker can use this to crash the affected software by providing and configuring a malicious UMC server or by manipulating the traffic from a legitimate UMC server (i.e. leveraging CVE-2023-48427).", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.0 SP2 Update 2 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109825710/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-48431" } ] }
var-202312-0209
Vulnerability from variot
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0209", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinec ins", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.0" }, { "model": "sinec ins", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-48429" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-48429" } ] }, "cve": "CVE-2023-48429", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "LOW", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "NONE", "exploitabilityScore": 1.2, "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-48429", "trust": 1.0, "value": "LOW" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-48429" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.", "sources": [ { "db": "NVD", "id": "CVE-2023-48429" } ], "trust": 1.0 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-077170", "trust": 1.0 }, { "db": "NVD", "id": "CVE-2023-48429", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-48429" } ] }, "id": "VAR-202312-0209", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.20766129 }, "last_update_date": "2023-12-18T11:11:19.708000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-754", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-48429" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-48429" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "NVD", "id": "CVE-2023-48429" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-12T12:15:15.083000", "db": "NVD", "id": "CVE-2023-48429" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-14T19:37:51.017000", "db": "NVD", "id": "CVE-2023-48429" } ] } }
gsd-2023-48429
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-48429", "id": "GSD-2023-48429" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-48429" ], "details": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.", "id": "GSD-2023-48429", "modified": "2023-12-13T01:20:39.809414Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2023-48429", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINEC INS", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V1.0 SP2 Update 2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart." } ] }, "impact": { "cvss": [ { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-394", "lang": "eng", "value": "CWE-394: Unexpected Status Code or Return Value" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf" } ] } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*", "matchCriteriaId": "C89891C1-DFD7-4E1F-80A9-7485D86A15B5", "versionEndExcluding": "1.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*", "matchCriteriaId": "4664B195-AF14-4834-82B3-0B2C98020EB6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "75BC588E-CDF0-404E-AD61-02093A1DF343", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "A334F7B4-7283-4453-BAED-D2E01B7F8A6E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*", "matchCriteriaId": "A6BEA71C-CA81-4B5D-A688-2B21E62DC351", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEC INS (Todas las versiones \u0026lt; V1.0 SP2 Update 2). La interfaz de usuario web de los dispositivos afectados no comprueba la longitud de los par\u00e1metros en determinadas condiciones. Esto permite que un administrador malintencionado bloquee el servidor enviando una solicitud manipulada al servidor. El servidor se reiniciar\u00e1 autom\u00e1ticamente." } ], "id": "CVE-2023-48429", "lastModified": "2023-12-14T19:37:51.017", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 1.4, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-12-12T12:15:15.083", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-754" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-394" } ], "source": "productcert@siemens.com", "type": "Secondary" } ] } } } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.