Action not permitted
Modal body text goes here.
cve-2023-49691
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T22:01:25.906Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions \u003c V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions \u003c V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions \u003c V8.0). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-13T07:53:58.093Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49691", "datePublished": "2023-12-12T11:27:24.588Z", "dateReserved": "2023-11-29T17:51:25.463Z", "dateUpdated": "2024-08-13T07:53:58.093Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-49691\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-12-12T12:15:15.990\",\"lastModified\":\"2024-08-13T08:15:09.340\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions \u003c V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions \u003c V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions \u003c V8.0). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en: \\nRUGGEDCOM RM1224 LTE(4G) EU (Todas las versiones \u0026lt; V8.0), \\nRUGGEDCOM RM1224 LTE(4G) NAM (Todas las versiones \u0026lt; V8.0), \\nSCALANCE M804PB (Todas las versiones \u0026lt; V8.0), \\nSCALANCE M812-1 ADSL-Router (Anexo A) (Todas las versiones \u0026lt; V8.0),\\nSCALANCE M812-1 ADSL-Router (Anexo B) (Todas las versiones \u0026lt; V8.0),\\nSCALANCE M816-1 ADSL-Router (Anexo A) (Todas las versiones \u0026lt; V8.0),\\nSCALANCE M816-1 ADSL-Router (Anexo B) (Todas las versiones \u0026lt; V8.0),\\nSCALANCE M826-2 SHDSL-Router (Todas las versiones \u0026lt; V8.0), \\nSCALANCE M874-2 ( Todas las versiones \u0026lt; V8.0), \\nSCALANCE M874-3 (Todas las versiones \u0026lt; V8.0), \\nSCALANCE M876-3 (EVDO) (Todas las versiones \u0026lt; V8.0), \\nSCALANCE M876-3 (ROK) (Todas las versiones \u0026lt; V8. 0), \\nSCALANCE M876-4 (Todas las versiones \u0026lt; V8.0), \\nSCALANCE M876-4 (EU) (Todas las versiones \u0026lt; V8.0), \\nSCALANCE M876-4 (NAM) (Todas las versiones \u0026lt; V8.0), \\nSCALANCE MUM853 -1 (UE) (Todas las versiones \u0026lt; V8.0), \\nSCALANCE MUM856-1 (UE) (Todas las versiones \u0026lt; V8.0), \\nSCALANCE MUM856-1 (RoW) (Todas las versiones \u0026lt; V8.0), \\nSCALANCE S615 (Todas versiones \u0026lt; V8.0), \\nSCALANCE S615 EEC (Todas las versiones \u0026lt; V8.0). \\nExiste una vulnerabilidad de neutralizaci\u00f3n inadecuada de elementos especiales utilizados en un comando del sistema operativo con privilegios de root en el manejo de la configuraci\u00f3n DDNS. Esto podr\u00eda permitir a administradores locales maliciosos emitir comandos a nivel del sistema despu\u00e9s de una actualizaci\u00f3n exitosa de la direcci\u00f3n IP.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk6108-4am00-2ba2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FF17A4F6-6057-4A37-87E7-9BCADD629FF7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk6108-4am00-2ba2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"7D78FE89-5ADC-45CB-8EDC-AA657F106E07\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk6108-4am00-2da2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6C6F2102-116D-4488-9FEC-2A97DC6C5964\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk6108-4am00-2da2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"58930E3B-A968-4098-9087-4C740EF376D9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5804-0ap00-2aa2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ABB76E7F-193D-4AFA-A820-A3D93D1AAA32\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5804-0ap00-2aa2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"3F21BF0A-F11E-46F7-9E29-C56998E72387\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5812-1aa00-2aa2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"374B9F0F-D572-4CB3-8A8C-778AE405E4FA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5812-1aa00-2aa2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"ECAC1DA7-D83A-4FB0-A961-5613B45327B6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5812-1ba00-2aa2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B8A8BB09-B2DC-4F09-A051-FC1ACCA76627\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5812-1ba00-2aa2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"9EA49DAA-7120-4812-A208-5DAC42D6ECB0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5816-1aa00-2aa2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A8A090F9-63B9-4C02-8FF5-91A99231434A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5816-1aa00-2aa2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"ABC8E30A-6736-4305-9113-E7D2E151D3E1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5816-1ba00-2aa2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A1FC0649-5A59-47C3-92F8-22A27EA08495\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5816-1ba00-2aa2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"DDD88150-70D8-444C-8368-957D9C14E0CD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5826-2ab00-2ab2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"58C61EFF-461A-4FA0-B851-4B838FC9762F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5826-2ab00-2ab2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"2156396E-75DC-4993-BE4B-66FD912CBFD9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5874-2aa00-2aa2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"6B19E755-B69C-4D0F-B69C-17C6F03DED37\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5874-2aa00-2aa2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BA7267C4-1486-49AF-B5F9-2A40DC285E86\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5874-3aa00-2aa2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"40EFCF99-C271-4F47-ACA3-B294855A3C35\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5874-3aa00-2aa2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B82271D5-62F9-4483-A199-AB306F560E70\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5876-3aa02-2ba2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"DF90538A-D487-4F20-B938-8B934F84C24E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5876-3aa02-2ba2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AAFD5B12-FE85-432D-9169-657E8CA7FDB5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5876-3aa02-2ea2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"6CB6CC96-7F8B-400D-A094-81241AC0BE3B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5876-3aa02-2ea2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F55773A9-F64F-4365-8249-B1500C809D63\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5876-4aa10-2ba2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"D4610695-66D5-4F8A-A11E-721B30DA5904\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5876-4aa10-2ba2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2BE36DEA-AEF7-4F39-B3C0-52ECBA170333\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5876-4aa00-2ba2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"79C98BF8-4D0F-4A9F-9B3E-0E4D5ABE7E66\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5876-4aa00-2ba2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8040F274-DC42-466F-B13A-4DEA36B351DC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5876-4aa00-2da2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"0730D773-35A2-411C-AB41-EB124F33006A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5876-4aa00-2da2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D28BCB70-1DA2-4C1D-8FA5-B7242163C3DC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5853-2ea00-2da1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"71DEC2D7-DE0E-41D6-857C-E7F3BEEB85B6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5853-2ea00-2da1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"39CFB4DB-2628-49C8-BEF7-DB0A27FEA286\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5856-2ea00-3da1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"A90AB343-67D5-4205-8B81-66BFE2D3B230\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5856-2ea00-3da1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AD59C631-F68B-4BB1-ACF1-BDE034214B20\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5856-2ea00-3aa1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"BF69EE86-5E8A-460A-AA47-3EC1475AB8B2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5856-2ea00-3aa1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D3CE8D68-CCE8-49E8-8229-5D64E5F7C67B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5615-0aa00-2aa2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"BE2DDADD-E6A4-43DD-9317-4AFCB4B970AF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5615-0aa00-2aa2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CF189379-EA02-4FCE-8E85-51C7CFD1674C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk5615-0aa01-2aa2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.0\",\"matchCriteriaId\":\"2F99BBBF-2AC0-4F02-9B95-5A3DD3D0B4EC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk5615-0aa01-2aa2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B83CF684-8E84-4ECD-9090-8B8997008108\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-180704.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-602936.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-690517.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
icsa-24-165-12
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SCALANCE W700 802.11 AX Family is affected by multiple vulnerabilities.\n\nSiemens recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-690517: Multiple Vulnerabilities in SCALANCE W700 802.11 AX Family - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-690517.json" }, { "category": "self", "summary": "SSA-690517: Multiple Vulnerabilities in SCALANCE W700 802.11 AX Family - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html" }, { "category": "self", "summary": "SSA-690517: Multiple Vulnerabilities in SCALANCE W700 802.11 AX Family - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-690517.pdf" }, { "category": "self", "summary": "SSA-690517: Multiple Vulnerabilities in SCALANCE W700 802.11 AX Family - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-690517.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-165-12 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-165-12.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-165-12 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-12" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SCALANCE W700", "tracking": { "current_release_date": "2024-06-11T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-165-12", "initial_release_date": "2024-06-11T00:00:00.000000Z", "revision_history": [ { "date": "2024-06-11T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-7DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-7DC0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-7DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0)", "product_id": "CSAFPID-0004", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)", "product_id": "CSAFPID-0005", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7DC0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)", "product_id": "CSAFPID-0006", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0)", "product_id": "CSAFPID-0007", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7TA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)", "product_id": "CSAFPID-0008", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7TC0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)", "product_id": "CSAFPID-0009", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7TB0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)", "product_id": "CSAFPID-0010", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3AA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)", "product_id": "CSAFPID-0011", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)", "product_id": "CSAFPID-0012", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3AB0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)", "product_id": "CSAFPID-0013", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0)", "product_id": "CSAFPID-0014", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-3DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)", "product_id": "CSAFPID-0015", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-3DC0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0)", "product_id": "CSAFPID-0016", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-3DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-46144", "cwe": { "id": "CWE-664", "name": "Improper Control of a Resource Through its Lifetime" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "title": "CVE-2022-46144" }, { "cve": "CVE-2023-44317", "cwe": { "id": "CWE-349", "name": "Acceptance of Extraneous Untrusted Data With Trusted Data" }, "notes": [ { "category": "summary", "text": "Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "title": "CVE-2023-44317" }, { "cve": "CVE-2023-44318", "cwe": { "id": "CWE-321", "name": "Use of Hard-coded Cryptographic Key" }, "notes": [ { "category": "summary", "text": "Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration information from the exported file.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "title": "CVE-2023-44318" }, { "cve": "CVE-2023-44319", "cwe": { "id": "CWE-328", "name": "Use of Weak Hash" }, "notes": [ { "category": "summary", "text": "Affected devices use a weak checksum algorithm to protect the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that tricks a legitimate administrator to upload a modified configuration file to change the configuration of an affected device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "title": "CVE-2023-44319" }, { "cve": "CVE-2023-44373", "cwe": { "id": "CWE-74", "name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "title": "CVE-2023-44373" }, { "cve": "CVE-2023-44374", "cwe": { "id": "CWE-567", "name": "Unsynchronized Access to Shared Data in a Multithreaded Context" }, "notes": [ { "category": "summary", "text": "Affected devices allow to change the password, but insufficiently check which password is to be changed. With this an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user allowing her to escalate her privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "title": "CVE-2023-44374" }, { "cve": "CVE-2023-49691", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016" ] } ], "title": "CVE-2023-49691" } ] }
icsa-24-046-09
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SCALANCE SC-600 Family before V3.1 is affected by multiple vulnerabilities.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-602936.json" }, { "category": "self", "summary": "SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.1 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html" }, { "category": "self", "summary": "SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-602936.pdf" }, { "category": "self", "summary": "SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-602936.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-046-09 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-046-09.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-046-09 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-09" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SCALANCE SC-600 Family", "tracking": { "current_release_date": "2024-02-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-046-09", "initial_release_date": "2024-02-13T00:00:00.000000Z", "revision_history": [ { "date": "2024-02-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK5622-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK5622-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK5622-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)", "product_id": "CSAFPID-0004", "product_identification_helper": { "model_numbers": [ "6GK5626-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)", "product_id": "CSAFPID-0005", "product_identification_helper": { "model_numbers": [ "6GK5626-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)", "product_id": "CSAFPID-0006", "product_identification_helper": { "model_numbers": [ "6GK5626-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)", "product_id": "CSAFPID-0007", "product_identification_helper": { "model_numbers": [ "6GK5632-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)", "product_id": "CSAFPID-0008", "product_identification_helper": { "model_numbers": [ "6GK5632-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)", "product_id": "CSAFPID-0009", "product_identification_helper": { "model_numbers": [ "6GK5632-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)", "product_id": "CSAFPID-0010", "product_identification_helper": { "model_numbers": [ "6GK5636-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)", "product_id": "CSAFPID-0011", "product_identification_helper": { "model_numbers": [ "6GK5636-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)", "product_id": "CSAFPID-0012", "product_identification_helper": { "model_numbers": [ "6GK5636-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)", "product_id": "CSAFPID-0013", "product_identification_helper": { "model_numbers": [ "6GK5642-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)", "product_id": "CSAFPID-0014", "product_identification_helper": { "model_numbers": [ "6GK5642-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)", "product_id": "CSAFPID-0015", "product_identification_helper": { "model_numbers": [ "6GK5642-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)", "product_id": "CSAFPID-0016", "product_identification_helper": { "model_numbers": [ "6GK5646-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)", "product_id": "CSAFPID-0017", "product_identification_helper": { "model_numbers": [ "6GK5646-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)", "product_id": "CSAFPID-0018", "product_identification_helper": { "model_numbers": [ "6GK5646-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-44317", "cwe": { "id": "CWE-349", "name": "Acceptance of Extraneous Untrusted Data With Trusted Data" }, "notes": [ { "category": "summary", "text": "Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109821991/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] } ], "title": "CVE-2023-44317" }, { "cve": "CVE-2023-44319", "cwe": { "id": "CWE-328", "name": "Use of Weak Hash" }, "notes": [ { "category": "summary", "text": "Affected devices use a weak checksum algorithm to protect the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that tricks a legitimate administrator to upload a modified configuration file to change the configuration of an affected device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109827038/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ] } ], "title": "CVE-2023-44319" }, { "cve": "CVE-2023-44320", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain modifications in the web interface allowing an authenticated attacker to influence the user interface configured by an administrator.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109827038/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ] } ], "title": "CVE-2023-44320" }, { "cve": "CVE-2023-44321", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0009", "CSAFPID-0012", "CSAFPID-0015", "CSAFPID-0018" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0009", "CSAFPID-0012", "CSAFPID-0015", "CSAFPID-0018" ] }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0009", "CSAFPID-0012", "CSAFPID-0015", "CSAFPID-0018" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0003", "CSAFPID-0006", "CSAFPID-0009", "CSAFPID-0012", "CSAFPID-0015", "CSAFPID-0018" ] } ], "title": "CVE-2023-44321" }, { "cve": "CVE-2023-44322", "cwe": { "id": "CWE-252", "name": "Unchecked Return Value" }, "notes": [ { "category": "summary", "text": "Affected devices can be configured to send emails when certain events occur on the device. When presented with an invalid response from the SMTP server, the device triggers an error that disrupts email sending. An attacker with access to the network can use this to do disable notification of users when certain events occur.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109827038/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0005", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0014", "CSAFPID-0017" ] } ], "title": "CVE-2023-44322" }, { "cve": "CVE-2023-44373", "cwe": { "id": "CWE-74", "name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109821991/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] } ], "title": "CVE-2023-44373" }, { "cve": "CVE-2023-49691", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109821991/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] } ], "title": "CVE-2023-49691" }, { "cve": "CVE-2023-49692", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109821991/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0004", "CSAFPID-0007", "CSAFPID-0010", "CSAFPID-0013", "CSAFPID-0016" ] } ], "title": "CVE-2023-49692" } ] }
icsa-23-348-14
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SCALANCE M-800/S615 Family before V8.0 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SCALANCE M-800 / S615 and recommends to update to the latest version. Siemens recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-180704: Multiple Vulnerabilities in SCALANCE M-800/S615 Family before V8.0 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-180704.json" }, { "category": "self", "summary": "SSA-180704: Multiple Vulnerabilities in SCALANCE M-800/S615 Family before V8.0 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html" }, { "category": "self", "summary": "SSA-180704: Multiple Vulnerabilities in SCALANCE M-800/S615 Family before V8.0 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf" }, { "category": "self", "summary": "SSA-180704: Multiple Vulnerabilities in SCALANCE M-800/S615 Family before V8.0 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-180704.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-348-14 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-348-14.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-348-14 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-14" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens RUGGEDCOM and SCALANCE M-800/S615 Family", "tracking": { "current_release_date": "2023-12-12T00:00:00Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-348-14", "initial_release_date": "2023-12-12T00:00:00Z", "revision_history": [ { "date": "2023-12-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)", "product_id": "1", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2BA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)", "product_id": "2", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2BA2" ] } } } ], "category": "product_name", "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)", "product_id": "3", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2DA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)", "product_id": "4", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2DA2" ] } } } ], "category": "product_name", "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)", "product_id": "5", "product_identification_helper": { "model_numbers": [ "6GK5804-0AP00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)", "product_id": "6", "product_identification_helper": { "model_numbers": [ "6GK5804-0AP00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)", "product_id": "7", "product_identification_helper": { "model_numbers": [ "6GK5812-1AA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)", "product_id": "8", "product_identification_helper": { "model_numbers": [ "6GK5812-1AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)", "product_id": "9", "product_identification_helper": { "model_numbers": [ "6GK5812-1BA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)", "product_id": "10", "product_identification_helper": { "model_numbers": [ "6GK5812-1BA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)", "product_id": "11", "product_identification_helper": { "model_numbers": [ "6GK5816-1AA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)", "product_id": "12", "product_identification_helper": { "model_numbers": [ "6GK5816-1AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)", "product_id": "13", "product_identification_helper": { "model_numbers": [ "6GK5816-1BA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)", "product_id": "14", "product_identification_helper": { "model_numbers": [ "6GK5816-1BA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)", "product_id": "15", "product_identification_helper": { "model_numbers": [ "6GK5826-2AB00-2AB2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)", "product_id": "16", "product_identification_helper": { "model_numbers": [ "6GK5826-2AB00-2AB2" ] } } } ], "category": "product_name", "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)", "product_id": "17", "product_identification_helper": { "model_numbers": [ "6GK5874-2AA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)", "product_id": "18", "product_identification_helper": { "model_numbers": [ "6GK5874-2AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)", "product_id": "19", "product_identification_helper": { "model_numbers": [ "6GK5874-3AA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)", "product_id": "20", "product_identification_helper": { "model_numbers": [ "6GK5874-3AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)", "product_id": "21", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2BA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)", "product_id": "22", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)", "product_id": "23", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2EA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)", "product_id": "24", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2EA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)", "product_id": "25", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA10-2BA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)", "product_id": "26", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA10-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)", "product_id": "27", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2BA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)", "product_id": "28", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)", "product_id": "29", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2DA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)", "product_id": "30", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2DA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)", "product_id": "31", "product_identification_helper": { "model_numbers": [ "6GK5853-2EA00-2DA1" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)", "product_id": "32", "product_identification_helper": { "model_numbers": [ "6GK5853-2EA00-2DA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)", "product_id": "33", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3DA1" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)", "product_id": "34", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3DA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)", "product_id": "35", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3AA1" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)", "product_id": "36", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3AA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE S615 (6GK5615-0AA00-2AA2)", "product_id": "37", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE S615 (6GK5615-0AA00-2AA2)", "product_id": "38", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE S615 (6GK5615-0AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE S615 EEC (6GK5615-0AA01-2AA2)", "product_id": "39", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA01-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE S615 EEC (6GK5615-0AA01-2AA2)", "product_id": "40", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA01-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE S615 EEC (6GK5615-0AA01-2AA2)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-46143", "cwe": { "id": "CWE-1284", "name": "Improper Validation of Specified Quantity in Input" }, "notes": [ { "category": "summary", "text": "Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2022-46143" }, { "cve": "CVE-2023-44318", "cwe": { "id": "CWE-321", "name": "Use of Hard-coded Cryptographic Key" }, "notes": [ { "category": "summary", "text": "Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration information from the exported file.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "title": "CVE-2023-44318" }, { "cve": "CVE-2023-44319", "cwe": { "id": "CWE-328", "name": "Use of Weak Hash" }, "notes": [ { "category": "summary", "text": "Affected devices use a weak checksum algorithm to protect the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that tricks a legitimate administrator to upload a modified configuration file to change the configuration of an affected device.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2023-44319" }, { "cve": "CVE-2023-44320", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain modifications in the web interface allowing an authenticated attacker to influence the user interface configured by an administrator.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "title": "CVE-2023-44320" }, { "cve": "CVE-2023-44321", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "title": "CVE-2023-44321" }, { "cve": "CVE-2023-44322", "cwe": { "id": "CWE-252", "name": "Unchecked Return Value" }, "notes": [ { "category": "summary", "text": "Affected devices can be configured to send emails when certain events occur on the device. When presented with an invalid response from the SMTP server, the device triggers an error that disrupts email sending. An attacker with access to the network can use this to do disable notification of users when certain events occur.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2023-44322" }, { "cve": "CVE-2023-44373", "cwe": { "id": "CWE-74", "name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2023-44373" }, { "cve": "CVE-2023-44374", "cwe": { "id": "CWE-567", "name": "Unsynchronized Access to Shared Data in a Multithreaded Context" }, "notes": [ { "category": "summary", "text": "Affected devices allow to change the password, but insufficiently check which password is to be changed. With this an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user allowing her to escalate her privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2023-44374" }, { "cve": "CVE-2023-49691", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2023-49691" } ] }
ssa-690517
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SCALANCE W700 802.11 AX Family is affected by multiple vulnerabilities.\n\nSiemens recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-690517: Multiple Vulnerabilities in SCALANCE W700 802.11 AX Family - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html" }, { "category": "self", "summary": "SSA-690517: Multiple Vulnerabilities in SCALANCE W700 802.11 AX Family - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-690517.json" }, { "category": "self", "summary": "SSA-690517: Multiple Vulnerabilities in SCALANCE W700 802.11 AX Family - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-690517.pdf" }, { "category": "self", "summary": "SSA-690517: Multiple Vulnerabilities in SCALANCE W700 802.11 AX Family - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-690517.txt" } ], "title": "SSA-690517: Multiple Vulnerabilities in SCALANCE W700 802.11 AX Family", "tracking": { "current_release_date": "2024-06-11T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-690517", "initial_release_date": "2024-06-11T00:00:00Z", "revision_history": [ { "date": "2024-06-11T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)", "product_id": "1", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-7DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)", "product_id": "2", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-7DC0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)", "product_id": "3", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-7DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0)", "product_id": "4", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)", "product_id": "5", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7DC0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)", "product_id": "6", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0)", "product_id": "7", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7TA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)", "product_id": "8", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7TC0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)", "product_id": "9", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7TB0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)", "product_id": "10", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3AA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)", "product_id": "11", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)", "product_id": "12", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3AB0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)", "product_id": "13", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0)", "product_id": "14", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-3DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)", "product_id": "15", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-3DC0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0)", "product_id": "16", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-3DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-46144", "cwe": { "id": "CWE-664", "name": "Improper Control of a Resource Through its Lifetime" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "title": "CVE-2022-46144" }, { "cve": "CVE-2023-44317", "cwe": { "id": "CWE-349", "name": "Acceptance of Extraneous Untrusted Data With Trusted Data" }, "notes": [ { "category": "summary", "text": "Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "title": "CVE-2023-44317" }, { "cve": "CVE-2023-44318", "cwe": { "id": "CWE-321", "name": "Use of Hard-coded Cryptographic Key" }, "notes": [ { "category": "summary", "text": "Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration information from the exported file.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "title": "CVE-2023-44318" }, { "cve": "CVE-2023-44319", "cwe": { "id": "CWE-328", "name": "Use of Weak Hash" }, "notes": [ { "category": "summary", "text": "Affected devices use a weak checksum algorithm to protect the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that tricks a legitimate administrator to upload a modified configuration file to change the configuration of an affected device.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "title": "CVE-2023-44319" }, { "cve": "CVE-2023-44373", "cwe": { "id": "CWE-74", "name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "title": "CVE-2023-44373" }, { "cve": "CVE-2023-44374", "cwe": { "id": "CWE-567", "name": "Unsynchronized Access to Shared Data in a Multithreaded Context" }, "notes": [ { "category": "summary", "text": "Affected devices allow to change the password, but insufficiently check which password is to be changed. With this an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user allowing her to escalate her privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "title": "CVE-2023-44374" }, { "cve": "CVE-2023-49691", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16" ] } ], "title": "CVE-2023-49691" } ] }
ssa-602936
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SCALANCE SC-600 Family before V3.1 is affected by multiple vulnerabilities.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.1 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html" }, { "category": "self", "summary": "SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-602936.json" }, { "category": "self", "summary": "SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-602936.pdf" }, { "category": "self", "summary": "SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-602936.txt" } ], "title": "SSA-602936: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.1", "tracking": { "current_release_date": "2024-02-13T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-602936", "initial_release_date": "2024-02-13T00:00:00Z", "revision_history": [ { "date": "2024-02-13T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)", "product_id": "1", "product_identification_helper": { "model_numbers": [ "6GK5622-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)", "product_id": "2", "product_identification_helper": { "model_numbers": [ "6GK5622-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)", "product_id": "3", "product_identification_helper": { "model_numbers": [ "6GK5622-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)", "product_id": "4", "product_identification_helper": { "model_numbers": [ "6GK5626-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)", "product_id": "5", "product_identification_helper": { "model_numbers": [ "6GK5626-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)", "product_id": "6", "product_identification_helper": { "model_numbers": [ "6GK5626-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)", "product_id": "7", "product_identification_helper": { "model_numbers": [ "6GK5632-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)", "product_id": "8", "product_identification_helper": { "model_numbers": [ "6GK5632-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)", "product_id": "9", "product_identification_helper": { "model_numbers": [ "6GK5632-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)", "product_id": "10", "product_identification_helper": { "model_numbers": [ "6GK5636-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)", "product_id": "11", "product_identification_helper": { "model_numbers": [ "6GK5636-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)", "product_id": "12", "product_identification_helper": { "model_numbers": [ "6GK5636-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)", "product_id": "13", "product_identification_helper": { "model_numbers": [ "6GK5642-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)", "product_id": "14", "product_identification_helper": { "model_numbers": [ "6GK5642-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)", "product_id": "15", "product_identification_helper": { "model_numbers": [ "6GK5642-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV3.0.2", "product": { "name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)", "product_id": "16", "product_identification_helper": { "model_numbers": [ "6GK5646-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "\u003cV3.1", "product": { "name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)", "product_id": "17", "product_identification_helper": { "model_numbers": [ "6GK5646-2GS00-2AC2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)", "product_id": "18", "product_identification_helper": { "model_numbers": [ "6GK5646-2GS00-2AC2" ] } } } ], "category": "product_name", "name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-44317", "cwe": { "id": "CWE-349", "name": "Acceptance of Extraneous Untrusted Data With Trusted Data" }, "notes": [ { "category": "summary", "text": "Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "4", "7", "10", "13", "16" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0.2 or later version", "product_ids": [ "1", "4", "7", "10", "13", "16" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109821991/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1", "4", "7", "10", "13", "16" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "4", "7", "10", "13", "16" ] } ], "title": "CVE-2023-44317" }, { "cve": "CVE-2023-44319", "cwe": { "id": "CWE-328", "name": "Use of Weak Hash" }, "notes": [ { "category": "summary", "text": "Affected devices use a weak checksum algorithm to protect the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that tricks a legitimate administrator to upload a modified configuration file to change the configuration of an affected device.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "5", "8", "11", "14", "17" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "2", "5", "8", "11", "14", "17" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109827038/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "2", "5", "8", "11", "14", "17" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "5", "8", "11", "14", "17" ] } ], "title": "CVE-2023-44319" }, { "cve": "CVE-2023-44320", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain modifications in the web interface allowing an authenticated attacker to influence the user interface configured by an administrator.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "5", "8", "11", "14", "17" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "2", "5", "8", "11", "14", "17" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109827038/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "2", "5", "8", "11", "14", "17" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "5", "8", "11", "14", "17" ] } ], "title": "CVE-2023-44320" }, { "cve": "CVE-2023-44321", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again.", "title": "Summary" } ], "product_status": { "known_affected": [ "3", "6", "9", "12", "15", "18" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "3", "6", "9", "12", "15", "18" ] }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "3", "6", "9", "12", "15", "18" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "3", "6", "9", "12", "15", "18" ] } ], "title": "CVE-2023-44321" }, { "cve": "CVE-2023-44322", "cwe": { "id": "CWE-252", "name": "Unchecked Return Value" }, "notes": [ { "category": "summary", "text": "Affected devices can be configured to send emails when certain events occur on the device. When presented with an invalid response from the SMTP server, the device triggers an error that disrupts email sending. An attacker with access to the network can use this to do disable notification of users when certain events occur.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "5", "8", "11", "14", "17" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "2", "5", "8", "11", "14", "17" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109827038/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "2", "5", "8", "11", "14", "17" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "5", "8", "11", "14", "17" ] } ], "title": "CVE-2023-44322" }, { "cve": "CVE-2023-44373", "cwe": { "id": "CWE-74", "name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "4", "7", "10", "13", "16" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0.2 or later version", "product_ids": [ "1", "4", "7", "10", "13", "16" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109821991/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1", "4", "7", "10", "13", "16" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "4", "7", "10", "13", "16" ] } ], "title": "CVE-2023-44373" }, { "cve": "CVE-2023-49691", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "4", "7", "10", "13", "16" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0.2 or later version", "product_ids": [ "1", "4", "7", "10", "13", "16" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109821991/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1", "4", "7", "10", "13", "16" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "4", "7", "10", "13", "16" ] } ], "title": "CVE-2023-49691" }, { "cve": "CVE-2023-49692", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "4", "7", "10", "13", "16" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.0.2 or later version", "product_ids": [ "1", "4", "7", "10", "13", "16" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109821991/" }, { "category": "workaround", "details": "Restrict access to application webserver for trusted users only", "product_ids": [ "1", "4", "7", "10", "13", "16" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "4", "7", "10", "13", "16" ] } ], "title": "CVE-2023-49692" } ] }
ssa-180704
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SCALANCE M-800/S615 Family before V8.0 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SCALANCE M-800 / S615 and recommends to update to the latest version. Siemens recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-180704: Multiple Vulnerabilities in SCALANCE M-800/S615 Family before V8.0 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html" }, { "category": "self", "summary": "SSA-180704: Multiple Vulnerabilities in SCALANCE M-800/S615 Family before V8.0 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-180704.json" }, { "category": "self", "summary": "SSA-180704: Multiple Vulnerabilities in SCALANCE M-800/S615 Family before V8.0 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf" }, { "category": "self", "summary": "SSA-180704: Multiple Vulnerabilities in SCALANCE M-800/S615 Family before V8.0 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-180704.txt" } ], "title": "SSA-180704: Multiple Vulnerabilities in SCALANCE M-800/S615 Family before V8.0", "tracking": { "current_release_date": "2023-12-12T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-180704", "initial_release_date": "2023-12-12T00:00:00Z", "revision_history": [ { "date": "2023-12-12T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)", "product_id": "1", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2BA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)", "product_id": "2", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2BA2" ] } } } ], "category": "product_name", "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)", "product_id": "3", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2DA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)", "product_id": "4", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2DA2" ] } } } ], "category": "product_name", "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)", "product_id": "5", "product_identification_helper": { "model_numbers": [ "6GK5804-0AP00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)", "product_id": "6", "product_identification_helper": { "model_numbers": [ "6GK5804-0AP00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)", "product_id": "7", "product_identification_helper": { "model_numbers": [ "6GK5812-1AA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)", "product_id": "8", "product_identification_helper": { "model_numbers": [ "6GK5812-1AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)", "product_id": "9", "product_identification_helper": { "model_numbers": [ "6GK5812-1BA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)", "product_id": "10", "product_identification_helper": { "model_numbers": [ "6GK5812-1BA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)", "product_id": "11", "product_identification_helper": { "model_numbers": [ "6GK5816-1AA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)", "product_id": "12", "product_identification_helper": { "model_numbers": [ "6GK5816-1AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)", "product_id": "13", "product_identification_helper": { "model_numbers": [ "6GK5816-1BA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)", "product_id": "14", "product_identification_helper": { "model_numbers": [ "6GK5816-1BA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)", "product_id": "15", "product_identification_helper": { "model_numbers": [ "6GK5826-2AB00-2AB2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)", "product_id": "16", "product_identification_helper": { "model_numbers": [ "6GK5826-2AB00-2AB2" ] } } } ], "category": "product_name", "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)", "product_id": "17", "product_identification_helper": { "model_numbers": [ "6GK5874-2AA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)", "product_id": "18", "product_identification_helper": { "model_numbers": [ "6GK5874-2AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)", "product_id": "19", "product_identification_helper": { "model_numbers": [ "6GK5874-3AA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)", "product_id": "20", "product_identification_helper": { "model_numbers": [ "6GK5874-3AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)", "product_id": "21", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2BA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)", "product_id": "22", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)", "product_id": "23", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2EA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)", "product_id": "24", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2EA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)", "product_id": "25", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA10-2BA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)", "product_id": "26", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA10-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)", "product_id": "27", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2BA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)", "product_id": "28", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)", "product_id": "29", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2DA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)", "product_id": "30", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2DA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)", "product_id": "31", "product_identification_helper": { "model_numbers": [ "6GK5853-2EA00-2DA1" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)", "product_id": "32", "product_identification_helper": { "model_numbers": [ "6GK5853-2EA00-2DA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)", "product_id": "33", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3DA1" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)", "product_id": "34", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3DA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)", "product_id": "35", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3AA1" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)", "product_id": "36", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3AA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE S615 (6GK5615-0AA00-2AA2)", "product_id": "37", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA00-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE S615 (6GK5615-0AA00-2AA2)", "product_id": "38", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE S615 (6GK5615-0AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.0", "product": { "name": "SCALANCE S615 EEC (6GK5615-0AA01-2AA2)", "product_id": "39", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA01-2AA2" ] } } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SCALANCE S615 EEC (6GK5615-0AA01-2AA2)", "product_id": "40", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA01-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE S615 EEC (6GK5615-0AA01-2AA2)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-46143", "cwe": { "id": "CWE-1284", "name": "Improper Validation of Specified Quantity in Input" }, "notes": [ { "category": "summary", "text": "Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2022-46143" }, { "cve": "CVE-2023-44318", "cwe": { "id": "CWE-321", "name": "Use of Hard-coded Cryptographic Key" }, "notes": [ { "category": "summary", "text": "Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration information from the exported file.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "title": "CVE-2023-44318" }, { "cve": "CVE-2023-44319", "cwe": { "id": "CWE-328", "name": "Use of Weak Hash" }, "notes": [ { "category": "summary", "text": "Affected devices use a weak checksum algorithm to protect the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that tricks a legitimate administrator to upload a modified configuration file to change the configuration of an affected device.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2023-44319" }, { "cve": "CVE-2023-44320", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the authentication when performing certain modifications in the web interface allowing an authenticated attacker to influence the user interface configured by an administrator.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "title": "CVE-2023-44320" }, { "cve": "CVE-2023-44321", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "4", "6", "8", "10", "12", "14", "16", "18", "20", "22", "24", "26", "28", "30", "32", "34", "36", "38", "40" ] } ], "title": "CVE-2023-44321" }, { "cve": "CVE-2023-44322", "cwe": { "id": "CWE-252", "name": "Unchecked Return Value" }, "notes": [ { "category": "summary", "text": "Affected devices can be configured to send emails when certain events occur on the device. When presented with an invalid response from the SMTP server, the device triggers an error that disrupts email sending. An attacker with access to the network can use this to do disable notification of users when certain events occur.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2023-44322" }, { "cve": "CVE-2023-44373", "cwe": { "id": "CWE-74", "name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2023-44373" }, { "cve": "CVE-2023-44374", "cwe": { "id": "CWE-567", "name": "Unsynchronized Access to Shared Data in a Multithreaded Context" }, "notes": [ { "category": "summary", "text": "Affected devices allow to change the password, but insufficiently check which password is to be changed. With this an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user allowing her to escalate her privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2023-44374" }, { "cve": "CVE-2023-49691", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.0 or later version", "product_ids": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109826372/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3", "5", "7", "9", "11", "13", "15", "17", "19", "21", "23", "25", "27", "29", "31", "33", "35", "37", "39" ] } ], "title": "CVE-2023-49691" } ] }
ghsa-7p78-839g-f66v
Vulnerability from github
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (All versions < V8.0), SCALANCE M804PB (All versions < V8.0), SCALANCE M812-1 ADSL-Router (Annex A) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (Annex B) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (Annex A) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (Annex B) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (All versions < V8.0), SCALANCE M874-2 (All versions < V8.0), SCALANCE M874-3 (All versions < V8.0), SCALANCE M876-3 (EVDO) (All versions < V8.0), SCALANCE M876-3 (ROK) (All versions < V8.0), SCALANCE M876-4 (All versions < V8.0), SCALANCE M876-4 (EU) (All versions < V8.0), SCALANCE M876-4 (NAM) (All versions < V8.0), SCALANCE MUM853-1 (EU) (All versions < V8.0), SCALANCE MUM856-1 (EU) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (All versions < V8.0), SCALANCE S615 (All versions < V8.0), SCALANCE S615 EEC (All versions < V8.0). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.
{ "affected": [], "aliases": [ "CVE-2023-49691" ], "database_specific": { "cwe_ids": [ "CWE-78" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2023-12-12T12:15:15Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (All versions \u003c V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (All versions \u003c V8.0), SCALANCE M804PB (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (Annex A) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (Annex B) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (Annex A) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (Annex B) (All versions \u003c V8.0), SCALANCE M826-2 SHDSL-Router (All versions \u003c V8.0), SCALANCE M874-2 (All versions \u003c V8.0), SCALANCE M874-3 (All versions \u003c V8.0), SCALANCE M876-3 (EVDO) (All versions \u003c V8.0), SCALANCE M876-3 (ROK) (All versions \u003c V8.0), SCALANCE M876-4 (All versions \u003c V8.0), SCALANCE M876-4 (EU) (All versions \u003c V8.0), SCALANCE M876-4 (NAM) (All versions \u003c V8.0), SCALANCE MUM853-1 (EU) (All versions \u003c V8.0), SCALANCE MUM856-1 (EU) (All versions \u003c V8.0), SCALANCE MUM856-1 (RoW) (All versions \u003c V8.0), SCALANCE S615 (All versions \u003c V8.0), SCALANCE S615 EEC (All versions \u003c V8.0). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.", "id": "GHSA-7p78-839g-f66v", "modified": "2024-06-11T09:30:57Z", "published": "2023-12-12T12:30:54Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-49691" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
gsd-2023-49691
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2023-49691", "id": "GSD-2023-49691" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-49691" ], "details": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (All versions \u003c V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (All versions \u003c V8.0), SCALANCE M804PB (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (Annex A) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (Annex B) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (Annex A) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (Annex B) (All versions \u003c V8.0), SCALANCE M826-2 SHDSL-Router (All versions \u003c V8.0), SCALANCE M874-2 (All versions \u003c V8.0), SCALANCE M874-3 (All versions \u003c V8.0), SCALANCE M876-3 (EVDO) (All versions \u003c V8.0), SCALANCE M876-3 (ROK) (All versions \u003c V8.0), SCALANCE M876-4 (All versions \u003c V8.0), SCALANCE M876-4 (EU) (All versions \u003c V8.0), SCALANCE M876-4 (NAM) (All versions \u003c V8.0), SCALANCE MUM853-1 (EU) (All versions \u003c V8.0), SCALANCE MUM856-1 (EU) (All versions \u003c V8.0), SCALANCE MUM856-1 (RoW) (All versions \u003c V8.0), SCALANCE S615 (All versions \u003c V8.0), SCALANCE S615 EEC (All versions \u003c V8.0). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.", "id": "GSD-2023-49691", "modified": "2023-12-13T01:20:35.302472Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2023-49691", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RUGGEDCOM RM1224 LTE(4G) EU", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "RUGGEDCOM RM1224 LTE(4G) NAM", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M804PB", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M812-1 ADSL-Router (Annex A)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M812-1 ADSL-Router (Annex B)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M816-1 ADSL-Router (Annex A)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M816-1 ADSL-Router (Annex B)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M826-2 SHDSL-Router", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M874-2", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M874-3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M876-3 (EVDO)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M876-3 (ROK)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M876-4", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M876-4 (EU)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE M876-4 (NAM)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE MUM853-1 (EU)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE MUM856-1 (EU)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE MUM856-1 (RoW)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE S615", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE S615 EEC", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V8.0" } ] } }, { "product_name": "SCALANCE SC622-2C", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.0.2" } ] } }, { "product_name": "SCALANCE SC626-2C", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.0.2" } ] } }, { "product_name": "SCALANCE SC632-2C", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.0.2" } ] } }, { "product_name": "SCALANCE SC636-2C", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.0.2" } ] } }, { "product_name": "SCALANCE SC642-2C", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.0.2" } ] } }, { "product_name": "SCALANCE SC646-2C", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.0.2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.0), SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2) (All versions \u003c V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.0), SCALANCE S615 (6GK5615-0AA00-2AA2) (All versions \u003c V8.0), SCALANCE S615 EEC (6GK5615-0AA01-2AA2) (All versions \u003c V8.0), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003c V3.0.2). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update." } ] }, "impact": { "cvss": [ { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-78", "lang": "eng", "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html" }, { "name": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html" } ] } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk6108-4am00-2ba2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7D78FE89-5ADC-45CB-8EDC-AA657F106E07", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk6108-4am00-2ba2:-:*:*:*:*:*:*:*", "matchCriteriaId": "FF17A4F6-6057-4A37-87E7-9BCADD629FF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk6108-4am00-2da2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58930E3B-A968-4098-9087-4C740EF376D9", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk6108-4am00-2da2:-:*:*:*:*:*:*:*", "matchCriteriaId": "6C6F2102-116D-4488-9FEC-2A97DC6C5964", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5804-0ap00-2aa2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F21BF0A-F11E-46F7-9E29-C56998E72387", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5804-0ap00-2aa2:-:*:*:*:*:*:*:*", "matchCriteriaId": "ABB76E7F-193D-4AFA-A820-A3D93D1AAA32", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5812-1aa00-2aa2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ECAC1DA7-D83A-4FB0-A961-5613B45327B6", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5812-1aa00-2aa2:-:*:*:*:*:*:*:*", "matchCriteriaId": "374B9F0F-D572-4CB3-8A8C-778AE405E4FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5812-1ba00-2aa2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9EA49DAA-7120-4812-A208-5DAC42D6ECB0", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5812-1ba00-2aa2:-:*:*:*:*:*:*:*", "matchCriteriaId": "B8A8BB09-B2DC-4F09-A051-FC1ACCA76627", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5816-1aa00-2aa2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ABC8E30A-6736-4305-9113-E7D2E151D3E1", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5816-1aa00-2aa2:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8A090F9-63B9-4C02-8FF5-91A99231434A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5816-1ba00-2aa2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DDD88150-70D8-444C-8368-957D9C14E0CD", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5816-1ba00-2aa2:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1FC0649-5A59-47C3-92F8-22A27EA08495", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5826-2ab00-2ab2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2156396E-75DC-4993-BE4B-66FD912CBFD9", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5826-2ab00-2ab2:-:*:*:*:*:*:*:*", "matchCriteriaId": "58C61EFF-461A-4FA0-B851-4B838FC9762F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5874-2aa00-2aa2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B19E755-B69C-4D0F-B69C-17C6F03DED37", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5874-2aa00-2aa2:-:*:*:*:*:*:*:*", "matchCriteriaId": "BA7267C4-1486-49AF-B5F9-2A40DC285E86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5874-3aa00-2aa2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "40EFCF99-C271-4F47-ACA3-B294855A3C35", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5874-3aa00-2aa2:-:*:*:*:*:*:*:*", "matchCriteriaId": "B82271D5-62F9-4483-A199-AB306F560E70", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5876-3aa02-2ba2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DF90538A-D487-4F20-B938-8B934F84C24E", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5876-3aa02-2ba2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AAFD5B12-FE85-432D-9169-657E8CA7FDB5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5876-3aa02-2ea2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6CB6CC96-7F8B-400D-A094-81241AC0BE3B", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5876-3aa02-2ea2:-:*:*:*:*:*:*:*", "matchCriteriaId": "F55773A9-F64F-4365-8249-B1500C809D63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5876-4aa10-2ba2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4610695-66D5-4F8A-A11E-721B30DA5904", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5876-4aa10-2ba2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BE36DEA-AEF7-4F39-B3C0-52ECBA170333", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5876-4aa00-2ba2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79C98BF8-4D0F-4A9F-9B3E-0E4D5ABE7E66", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5876-4aa00-2ba2:-:*:*:*:*:*:*:*", "matchCriteriaId": "8040F274-DC42-466F-B13A-4DEA36B351DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5876-4aa00-2da2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0730D773-35A2-411C-AB41-EB124F33006A", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5876-4aa00-2da2:-:*:*:*:*:*:*:*", "matchCriteriaId": "D28BCB70-1DA2-4C1D-8FA5-B7242163C3DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5853-2ea00-2da1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "71DEC2D7-DE0E-41D6-857C-E7F3BEEB85B6", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5853-2ea00-2da1:-:*:*:*:*:*:*:*", "matchCriteriaId": "39CFB4DB-2628-49C8-BEF7-DB0A27FEA286", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5856-2ea00-3da1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A90AB343-67D5-4205-8B81-66BFE2D3B230", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5856-2ea00-3da1:-:*:*:*:*:*:*:*", "matchCriteriaId": "AD59C631-F68B-4BB1-ACF1-BDE034214B20", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5856-2ea00-3aa1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BF69EE86-5E8A-460A-AA47-3EC1475AB8B2", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5856-2ea00-3aa1:-:*:*:*:*:*:*:*", "matchCriteriaId": "D3CE8D68-CCE8-49E8-8229-5D64E5F7C67B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5615-0aa00-2aa2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE2DDADD-E6A4-43DD-9317-4AFCB4B970AF", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5615-0aa00-2aa2:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF189379-EA02-4FCE-8E85-51C7CFD1674C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:6gk5615-0aa01-2aa2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2F99BBBF-2AC0-4F02-9B95-5A3DD3D0B4EC", "versionEndExcluding": "8.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:6gk5615-0aa01-2aa2:-:*:*:*:*:*:*:*", "matchCriteriaId": "B83CF684-8E84-4ECD-9090-8B8997008108", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.0), SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2) (All versions \u003c V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.0), SCALANCE S615 (6GK5615-0AA00-2AA2) (All versions \u003c V8.0), SCALANCE S615 EEC (6GK5615-0AA01-2AA2) (All versions \u003c V8.0), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003c V3.0.2). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en: \nRUGGEDCOM RM1224 LTE(4G) EU (Todas las versiones \u0026lt; V8.0), \nRUGGEDCOM RM1224 LTE(4G) NAM (Todas las versiones \u0026lt; V8.0), \nSCALANCE M804PB (Todas las versiones \u0026lt; V8.0), \nSCALANCE M812-1 ADSL-Router (Anexo A) (Todas las versiones \u0026lt; V8.0),\nSCALANCE M812-1 ADSL-Router (Anexo B) (Todas las versiones \u0026lt; V8.0),\nSCALANCE M816-1 ADSL-Router (Anexo A) (Todas las versiones \u0026lt; V8.0),\nSCALANCE M816-1 ADSL-Router (Anexo B) (Todas las versiones \u0026lt; V8.0),\nSCALANCE M826-2 SHDSL-Router (Todas las versiones \u0026lt; V8.0), \nSCALANCE M874-2 ( Todas las versiones \u0026lt; V8.0), \nSCALANCE M874-3 (Todas las versiones \u0026lt; V8.0), \nSCALANCE M876-3 (EVDO) (Todas las versiones \u0026lt; V8.0), \nSCALANCE M876-3 (ROK) (Todas las versiones \u0026lt; V8. 0), \nSCALANCE M876-4 (Todas las versiones \u0026lt; V8.0), \nSCALANCE M876-4 (EU) (Todas las versiones \u0026lt; V8.0), \nSCALANCE M876-4 (NAM) (Todas las versiones \u0026lt; V8.0), \nSCALANCE MUM853 -1 (UE) (Todas las versiones \u0026lt; V8.0), \nSCALANCE MUM856-1 (UE) (Todas las versiones \u0026lt; V8.0), \nSCALANCE MUM856-1 (RoW) (Todas las versiones \u0026lt; V8.0), \nSCALANCE S615 (Todas versiones \u0026lt; V8.0), \nSCALANCE S615 EEC (Todas las versiones \u0026lt; V8.0). \nExiste una vulnerabilidad de neutralizaci\u00f3n inadecuada de elementos especiales utilizados en un comando del sistema operativo con privilegios de root en el manejo de la configuraci\u00f3n DDNS. Esto podr\u00eda permitir a administradores locales maliciosos emitir comandos a nivel del sistema despu\u00e9s de una actualizaci\u00f3n exitosa de la direcci\u00f3n IP." } ], "id": "CVE-2023-49691", "lastModified": "2024-02-13T09:15:46.373", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2023-12-12T12:15:15.990", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "productcert@siemens.com", "type": "Primary" } ] } } } }
var-202312-0199
Vulnerability from variot
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE S615 EEC (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V3.0.2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V3.0.2), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update. 6gk6108-4am00-2ba2 firmware, 6gk6108-4am00-2da2 firmware, 6gk5804-0ap00-2aa2 Several Siemens products, such as firmware, OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers.
Siemens SCALANCE M-800/S615 series has an operating system command injection vulnerability that allows an attacker to execute commands on the system
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0199", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance m876-4", "scope": "lt", "trust": 1.8, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m812-1 adsl-router", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m816-1 adsl-router", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m876-3", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance mum856-1", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "v8.0" }, { "model": "6gk5826-2ab00-2ab2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5804-0ap00-2aa2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5853-2ea00-2da1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5874-2aa00-2aa2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5856-2ea00-3da1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5816-1aa00-2aa2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5876-4aa00-2ba2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5876-3aa02-2ba2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5876-4aa00-2da2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5856-2ea00-3aa1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5876-3aa02-2ea2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5812-1aa00-2aa2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5876-4aa10-2ba2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5816-1ba00-2aa2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk6108-4am00-2ba2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5812-1ba00-2aa2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5874-3aa00-2aa2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5615-0aa01-2aa2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5615-0aa00-2aa2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk6108-4am00-2da2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "6gk5856-2ea00-3aa1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5812-1aa00-2aa2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5615-0aa01-2aa2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5615-0aa00-2aa2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5856-2ea00-3da1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5876-3aa02-2ea2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5876-4aa00-2ba2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5812-1ba00-2aa2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5816-1ba00-2aa2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk6108-4am00-2da2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5826-2ab00-2ab2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5874-2aa00-2aa2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk6108-4am00-2ba2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5876-4aa10-2ba2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5876-3aa02-2ba2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5816-1aa00-2aa2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5876-4aa00-2da2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5853-2ea00-2da1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5874-3aa00-2aa2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6gk5804-0ap00-2aa2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ruggedcom rm1224 lte eu", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "ruggedcom rm1224 lte nam", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m804pb", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m826-2 shdsl-router", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m874-2", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m874-3", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance mum853-1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance s615", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance s615 eec", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97258" }, { "db": "JVNDB", "id": "JVNDB-2023-019858" }, { "db": "NVD", "id": "CVE-2023-49691" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk6108-4am00-2ba2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk6108-4am00-2ba2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk6108-4am00-2da2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk6108-4am00-2da2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5804-0ap00-2aa2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5804-0ap00-2aa2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5812-1aa00-2aa2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5812-1aa00-2aa2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5812-1ba00-2aa2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5812-1ba00-2aa2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5816-1aa00-2aa2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5816-1aa00-2aa2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5816-1ba00-2aa2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5816-1ba00-2aa2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5826-2ab00-2ab2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5826-2ab00-2ab2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5874-2aa00-2aa2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5874-2aa00-2aa2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5874-3aa00-2aa2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5874-3aa00-2aa2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5876-3aa02-2ba2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5876-3aa02-2ba2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5876-3aa02-2ea2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5876-3aa02-2ea2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5876-4aa10-2ba2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5876-4aa10-2ba2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5876-4aa00-2ba2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5876-4aa00-2ba2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5876-4aa00-2da2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5876-4aa00-2da2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5853-2ea00-2da1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5853-2ea00-2da1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5856-2ea00-3da1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5856-2ea00-3da1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5856-2ea00-3aa1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5856-2ea00-3aa1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5615-0aa00-2aa2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5615-0aa00-2aa2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6gk5615-0aa01-2aa2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6gk5615-0aa01-2aa2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-49691" } ] }, "cve": "CVE-2023-49691", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "MULTIPLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.4, "id": "CNVD-2023-97258", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.2, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.7, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-49691", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-49691", "trust": 1.8, "value": "MEDIUM" }, { "author": "productcert@siemens.com", "id": "CVE-2023-49691", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2023-97258", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97258" }, { "db": "JVNDB", "id": "JVNDB-2023-019858" }, { "db": "NVD", "id": "CVE-2023-49691" }, { "db": "NVD", "id": "CVE-2023-49691" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2) (All versions \u003c V8.0), SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2) (All versions \u003c V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.0), SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2) (All versions \u003c V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.0), SCALANCE S615 (6GK5615-0AA00-2AA2) (All versions \u003c V8.0), SCALANCE S615 EEC (6GK5615-0AA01-2AA2) (All versions \u003c V8.0), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003c V3.0.2), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update. 6gk6108-4am00-2ba2 firmware, 6gk6108-4am00-2da2 firmware, 6gk5804-0ap00-2aa2 Several Siemens products, such as firmware, OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. \n\r\n\r\nSiemens SCALANCE M-800/S615 series has an operating system command injection vulnerability that allows an attacker to execute commands on the system", "sources": [ { "db": "NVD", "id": "CVE-2023-49691" }, { "db": "JVNDB", "id": "JVNDB-2023-019858" }, { "db": "CNVD", "id": "CNVD-2023-97258" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-49691", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-180704", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-690517", "trust": 1.0 }, { "db": "SIEMENS", "id": "SSA-602936", "trust": 1.0 }, { "db": "ICS CERT", "id": "ICSA-23-348-14", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-24-046-09", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU91198149", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU98271228", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-019858", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-97258", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97258" }, { "db": "JVNDB", "id": "JVNDB-2023-019858" }, { "db": "NVD", "id": "CVE-2023-49691" } ] }, "id": "VAR-202312-0199", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-97258" } ], "trust": 1.5 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97258" } ] }, "last_update_date": "2024-06-12T20:03:27.408000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SCALANCE M-800/S615 series operating system command injection vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/500366" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97258" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.0 }, { "problemtype": "OS Command injection (CWE-78) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019858" }, { "db": "NVD", "id": "CVE-2023-49691" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-602936.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98271228/" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91198149/index.html" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-49691" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-14" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-09" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97258" }, { "db": "JVNDB", "id": "JVNDB-2023-019858" }, { "db": "NVD", "id": "CVE-2023-49691" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-97258" }, { "db": "JVNDB", "id": "JVNDB-2023-019858" }, { "db": "NVD", "id": "CVE-2023-49691" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-14T00:00:00", "db": "CNVD", "id": "CNVD-2023-97258" }, { "date": "2024-01-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-019858" }, { "date": "2023-12-12T12:15:15.990000", "db": "NVD", "id": "CVE-2023-49691" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T00:00:00", "db": "CNVD", "id": "CNVD-2023-97258" }, { "date": "2024-02-19T06:58:00", "db": "JVNDB", "id": "JVNDB-2023-019858" }, { "date": "2024-06-11T09:15:16.840000", "db": "NVD", "id": "CVE-2023-49691" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "in multiple Siemens products \u00a0OS\u00a0 Command injection vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019858" } ], "trust": 0.8 } }
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.