CVE-2023-5288 (GCVE-0-2023-5288)
Vulnerability from cvelistv5 – Published: 2023-09-29 11:37 – Updated: 2024-12-09 14:08
VLAI?
Summary
A remote unauthorized attacker may connect to the SIM1012, interact with the device and
change configuration settings. The adversary may also reset the SIM and in the worst case upload a
new firmware version to the device.
Severity ?
9.8 (Critical)
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:52:08.562Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.json"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:sick:sim1012:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sim1012",
"vendor": "sick",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5288",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-23T17:15:11.997557Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-09T14:08:49.408Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "SIM1012",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA remote unauthorized attacker may connect to the SIM1012, interact with the device and\nchange configuration settings. The adversary may also reset the SIM and in the worst case upload a\nnew firmware version to the device.\n\n"
}
],
"value": "\nA remote unauthorized attacker may connect to the SIM1012, interact with the device and\nchange configuration settings. The adversary may also reset the SIM and in the worst case upload a\nnew firmware version to the device.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-29T11:37:56.571Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nSICK recommends to disable port 2111 \u0026amp; 2122 once the SIM1012 is put into operation. The\ninformation how to disable the port can be retrieved from the SIM1012 API documentation. SICK\nrecommends using the SICK AppManager in version \u0026gt;=1.5.6 for the commissioning of the SIM1012.\n\n\n\u003cbr\u003e"
}
],
"value": "\nSICK recommends to disable port 2111 \u0026 2122 once the SIM1012 is put into operation. The\ninformation how to disable the port can be retrieved from the SIM1012 API documentation. SICK\nrecommends using the SICK AppManager in version \u003e=1.5.6 for the commissioning of the SIM1012.\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-5288",
"datePublished": "2023-09-29T11:37:56.571Z",
"dateReserved": "2023-09-29T10:17:33.150Z",
"dateUpdated": "2024-12-09T14:08:49.408Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:sick:sim1012-0p0g200_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"107B78AE-09FC-4A4C-AFD9-5AEB44B2A157\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:sick:sim1012-0p0g200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F9A757D0-FA59-4F71-95B9-2F1E2B991867\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"\\nA remote unauthorized attacker may connect to the SIM1012, interact with the device and\\nchange configuration settings. The adversary may also reset the SIM and in the worst case upload a\\nnew firmware version to the device.\\n\\n\"}, {\"lang\": \"es\", \"value\": \"Un atacante remoto no autorizado puede conectarse al SIM1012, interactuar con el dispositivo y cambiar los ajustes de configuraci\\u00f3n. El atacante tambi\\u00e9n puede restablecer la SIM y, en el peor de los casos, cargar una nueva versi\\u00f3n de firmware en el dispositivo.\"}]",
"id": "CVE-2023-5288",
"lastModified": "2024-11-21T08:41:27.523",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"psirt@sick.de\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
"published": "2023-09-29T12:15:13.437",
"references": "[{\"url\": \"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.json\", \"source\": \"psirt@sick.de\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.pdf\", \"source\": \"psirt@sick.de\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"https://sick.com/psirt\", \"source\": \"psirt@sick.de\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.json\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"https://sick.com/psirt\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "psirt@sick.de",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"psirt@sick.de\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-284\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-5288\",\"sourceIdentifier\":\"psirt@sick.de\",\"published\":\"2023-09-29T12:15:13.437\",\"lastModified\":\"2024-11-21T08:41:27.523\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA remote unauthorized attacker may connect to the SIM1012, interact with the device and\\nchange configuration settings. The adversary may also reset the SIM and in the worst case upload a\\nnew firmware version to the device.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Un atacante remoto no autorizado puede conectarse al SIM1012, interactuar con el dispositivo y cambiar los ajustes de configuraci\u00f3n. El atacante tambi\u00e9n puede restablecer la SIM y, en el peor de los casos, cargar una nueva versi\u00f3n de firmware en el dispositivo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@sick.de\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"psirt@sick.de\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sick:sim1012-0p0g200_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"107B78AE-09FC-4A4C-AFD9-5AEB44B2A157\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sick:sim1012-0p0g200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F9A757D0-FA59-4F71-95B9-2F1E2B991867\"}]}]}],\"references\":[{\"url\":\"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.json\",\"source\":\"psirt@sick.de\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.pdf\",\"source\":\"psirt@sick.de\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://sick.com/psirt\",\"source\":\"psirt@sick.de\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.json\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://sick.com/psirt\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://sick.com/psirt\", \"tags\": [\"issue-tracking\", \"x_transferred\"]}, {\"url\": \"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.pdf\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}, {\"url\": \"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.json\", \"tags\": [\"x_csaf\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T07:52:08.562Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-5288\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-23T17:15:11.997557Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:sick:sim1012:-:*:*:*:*:*:*:*\"], \"vendor\": \"sick\", \"product\": \"sim1012\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-23T17:16:50.789Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"SICK AG\", \"product\": \"SIM1012\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"affected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"\\nSICK recommends to disable port 2111 \u0026 2122 once the SIM1012 is put into operation. The\\ninformation how to disable the port can be retrieved from the SIM1012 API documentation. SICK\\nrecommends using the SICK AppManager in version \u003e=1.5.6 for the commissioning of the SIM1012.\\n\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\nSICK recommends to disable port 2111 \u0026amp; 2122 once the SIM1012 is put into operation. The\\ninformation how to disable the port can be retrieved from the SIM1012 API documentation. SICK\\nrecommends using the SICK AppManager in version \u0026gt;=1.5.6 for the commissioning of the SIM1012.\\n\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://sick.com/psirt\", \"tags\": [\"issue-tracking\"]}, {\"url\": \"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.pdf\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://sick.com/.well-known/csaf/white/2023/sca-2023-0008.json\", \"tags\": [\"x_csaf\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nA remote unauthorized attacker may connect to the SIM1012, interact with the device and\\nchange configuration settings. The adversary may also reset the SIM and in the worst case upload a\\nnew firmware version to the device.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\nA remote unauthorized attacker may connect to the SIM1012, interact with the device and\\nchange configuration settings. The adversary may also reset the SIM and in the worst case upload a\\nnew firmware version to the device.\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284 Improper Access Control\"}]}], \"providerMetadata\": {\"orgId\": \"a6863dd2-93fc-443d-bef1-79f0b5020988\", \"shortName\": \"SICK AG\", \"dateUpdated\": \"2023-09-29T11:37:56.571Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-5288\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-12-09T14:08:49.408Z\", \"dateReserved\": \"2023-09-29T10:17:33.150Z\", \"assignerOrgId\": \"a6863dd2-93fc-443d-bef1-79f0b5020988\", \"datePublished\": \"2023-09-29T11:37:56.571Z\", \"assignerShortName\": \"SICK AG\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…