cve-2023-5767
Vulnerability from cvelistv5
Published
2023-12-04 14:30
Modified
2024-08-02 08:07
Severity ?
EPSS score ?
Summary
A vulnerability exists in the webserver that affects the
RTU500 series product versions listed below. A malicious
actor could perform cross-site scripting on the webserver
due to an RDT language file being improperly sanitized.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Hitachi Energy | RTU500 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:07:32.705Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "RTU500", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "RTU500 series CMU Firmware version 12.0.1 \u2013 12.0.14" }, { "status": "affected", "version": "RTU500 series CMU Firmware version 12.2.1 \u2013 12.2.11" }, { "status": "affected", "version": "RTU500 series CMU Firmware version 12.4.1 \u2013 12.4.11" }, { "status": "affected", "version": "RTU500 series CMU Firmware version 12.6.1 \u2013 12.6.9" }, { "status": "affected", "version": "RTU500 series CMU Firmware version 12.7.1 \u2013 12.7.6" }, { "status": "affected", "version": "RTU500 series CMU Firmware version 13.2.1 \u2013 13.2.6" }, { "status": "affected", "version": "RTU500 series CMU Firmware version 13.4.1 \u2013 13.4.3" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA vulnerability exists in the webserver that affects the \nRTU500 series product versions listed below. A malicious \nactor could perform cross-site scripting on the webserver \ndue to an RDT language file being improperly sanitized.\n\n\n" } ], "value": "\nA vulnerability exists in the webserver that affects the \nRTU500 series product versions listed below. A malicious \nactor could perform cross-site scripting on the webserver \ndue to an RDT language file being improperly sanitized.\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-04T14:30:24.550Z", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2023-5767", "datePublished": "2023-12-04T14:30:23.253Z", "dateReserved": "2023-10-25T15:24:37.775Z", "dateUpdated": "2024-08-02T08:07:32.705Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-5767\",\"sourceIdentifier\":\"cybersecurity@hitachienergy.com\",\"published\":\"2023-12-04T15:15:07.613\",\"lastModified\":\"2023-12-07T17:54:21.037\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA vulnerability exists in the webserver that affects the \\nRTU500 series product versions listed below. A malicious \\nactor could perform cross-site scripting on the webserver \\ndue to an RDT language file being improperly sanitized.\\n\\n\\n\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad en el servidor web que afecta a las versiones de productos RTU500 series que se enumeran a continuaci\u00f3n. Un actor malintencionado podr\u00eda realizar cross-site scripting en el servidor web debido a que un archivo de idioma RDT no se ha sanitizado incorrectamente.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\",\"baseScore\":6.0,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.2,\"impactScore\":4.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:rtu520:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11AF93AD-200F-47A6-BA2C-F82165AFB50D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.1\",\"versionEndIncluding\":\"12.0.14\",\"matchCriteriaId\":\"2E81BEA6-121C-48D7-BAA9-91D652E6BC1A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.2.1\",\"versionEndIncluding\":\"12.2.11\",\"matchCriteriaId\":\"2469A78A-6F37-4F4B-BED8-060914B2D0A4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.4.1\",\"versionEndIncluding\":\"12.4.11\",\"matchCriteriaId\":\"E9E6934B-EBB2-45FB-8E4A-7D360CBA0F92\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.6.1\",\"versionEndIncluding\":\"12.6.9\",\"matchCriteriaId\":\"40D7C64F-54CC-4183-8420-011E2787541F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.7.1\",\"versionEndIncluding\":\"12.7.6\",\"matchCriteriaId\":\"BDD81EF6-9D45-4A2D-BFAA-D10005AEA046\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.1\",\"versionEndIncluding\":\"13.2.6\",\"matchCriteriaId\":\"8D5EFAE2-81D8-4E67-8515-137EAE453D6D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.4.1\",\"versionEndIncluding\":\"13.4.3\",\"matchCriteriaId\":\"DC740F55-F482-4BC2-9D39-D27F40EBB7C9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:rtu530:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FC6F9377-E6BB-4DEA-9D87-0AF792CBAC57\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.1\",\"versionEndIncluding\":\"12.0.14\",\"matchCriteriaId\":\"D9F00BAD-06B1-49BE-BD41-61DE749E1506\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.2.1\",\"versionEndIncluding\":\"12.2.11\",\"matchCriteriaId\":\"79BC5D4A-09B2-41FB-962A-CF580181EB2C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.4.1\",\"versionEndIncluding\":\"12.4.11\",\"matchCriteriaId\":\"A30CDB2F-E0CC-4440-9E59-AB339F94996F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.6.1\",\"versionEndIncluding\":\"12.6.9\",\"matchCriteriaId\":\"D6BC4865-4064-421C-A746-8CB3D9DBAD7B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.7.1\",\"versionEndIncluding\":\"12.7.6\",\"matchCriteriaId\":\"5995FE68-15EA-4CB6-A43C-49582E4DF58C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.1\",\"versionEndIncluding\":\"13.2.6\",\"matchCriteriaId\":\"6E5803D1-164F-40E2-A348-21538EE1787F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.4.1\",\"versionEndIncluding\":\"13.4.3\",\"matchCriteriaId\":\"74AE224C-8D72-4C5A-ABB7-CE447E26992C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:rtu540:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6EEFDEF0-883D-402B-9CD4-333A145E3C75\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.1\",\"versionEndIncluding\":\"12.0.14\",\"matchCriteriaId\":\"BBD5E8FC-3FB5-4300-BBF4-DDAF573F20F2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.2.1\",\"versionEndIncluding\":\"12.2.11\",\"matchCriteriaId\":\"803838B5-058E-436B-8CE5-BF711456F96B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.4.1\",\"versionEndIncluding\":\"12.4.11\",\"matchCriteriaId\":\"A0361A98-1496-4763-A489-DCAE0D0DF613\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.6.1\",\"versionEndIncluding\":\"12.6.9\",\"matchCriteriaId\":\"7DECEA34-8A96-4943-B351-5080C4D34996\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.7.1\",\"versionEndIncluding\":\"12.7.6\",\"matchCriteriaId\":\"AF24A6B2-D9CF-44DE-A470-A09753D3A1B8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.1\",\"versionEndIncluding\":\"13.2.6\",\"matchCriteriaId\":\"2B890C79-2919-48F4-9431-3B92C48089C0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.4.1\",\"versionEndIncluding\":\"13.4.3\",\"matchCriteriaId\":\"90834F09-E09B-46BE-94BC-5812E63DE98D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:rtu560:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"495DCBD6-D2D1-4295-81D1-6ACA1B2CA223\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.1\",\"versionEndIncluding\":\"12.0.14\",\"matchCriteriaId\":\"8AC22007-6E39-4C5A-A392-139B43F819C0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.2.1\",\"versionEndIncluding\":\"12.2.11\",\"matchCriteriaId\":\"6BDB5A36-9B2F-43F9-A81B-506C4660151F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.4.1\",\"versionEndIncluding\":\"12.4.11\",\"matchCriteriaId\":\"F25FBFD5-BC45-49C9-87D4-A9C05405490D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.6.1\",\"versionEndIncluding\":\"12.6.9\",\"matchCriteriaId\":\"63096BB3-C0F9-4089-B11C-DE958B150DA8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.7.1\",\"versionEndIncluding\":\"12.7.6\",\"matchCriteriaId\":\"CC2029C0-3710-4CBB-8CBE-9EBA5793506A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.2.1\",\"versionEndIncluding\":\"13.2.6\",\"matchCriteriaId\":\"CDFF9898-F8FF-4361-A22C-DD5E47054FED\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.4.1\",\"versionEndIncluding\":\"13.4.3\",\"matchCriteriaId\":\"18211DB4-DA86-4489-AFE1-48514160C1D4\"}]}]}],\"references\":[{\"url\":\"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176\u0026languageCode=en\u0026Preview=true\",\"source\":\"cybersecurity@hitachienergy.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.