CVE-2024-11187 (GCVE-0-2024-11187)

Vulnerability from cvelistv5 – Published: 2025-01-29 21:40 – Updated: 2025-02-11 19:02
VLAI?
Summary
It is possible to construct a zone such that some queries to it will generate responses containing numerous records in the Additional section. An attacker sending many such queries can cause either the authoritative server itself or an independent resolver to use disproportionate resources processing the queries. Zones will usually need to have been deliberately crafted to attack this exposure. This issue affects BIND 9 versions 9.11.0 through 9.11.37, 9.16.0 through 9.16.50, 9.18.0 through 9.18.32, 9.20.0 through 9.20.4, 9.21.0 through 9.21.3, 9.11.3-S1 through 9.11.37-S1, 9.16.8-S1 through 9.16.50-S1, and 9.18.11-S1 through 9.18.32-S1.
CWE
  • CWE-405 - Asymmetric Resource Consumption (Amplification)
Assigner
isc
References
Impacted products
Vendor Product Version
ISC BIND 9 Affected: 9.11.0 , ≤ 9.11.37 (custom)
Affected: 9.16.0 , ≤ 9.16.50 (custom)
Affected: 9.18.0 , ≤ 9.18.32 (custom)
Affected: 9.20.0 , ≤ 9.20.4 (custom)
Affected: 9.21.0 , ≤ 9.21.3 (custom)
Affected: 9.11.3-S1 , ≤ 9.11.37-S1 (custom)
Affected: 9.16.8-S1 , ≤ 9.16.50-S1 (custom)
Affected: 9.18.11-S1 , ≤ 9.18.32-S1 (custom)
Create a notification for this product.
Credits
ISC would like to thank Toshifumi Sakaguchi for bringing this vulnerability to our attention.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11187",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-30T15:27:46.174106Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-30T15:27:58.342Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-02-11T19:02:32.914Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://security.netapp.com/advisory/ntap-20250207-0002/"
          },
          {
            "url": "https://lists.debian.org/debian-lts-announce/2025/02/msg00011.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "BIND 9",
          "vendor": "ISC",
          "versions": [
            {
              "lessThanOrEqual": "9.11.37",
              "status": "affected",
              "version": "9.11.0",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "9.16.50",
              "status": "affected",
              "version": "9.16.0",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "9.18.32",
              "status": "affected",
              "version": "9.18.0",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "9.20.4",
              "status": "affected",
              "version": "9.20.0",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "9.21.3",
              "status": "affected",
              "version": "9.21.0",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "9.11.37-S1",
              "status": "affected",
              "version": "9.11.3-S1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "9.16.50-S1",
              "status": "affected",
              "version": "9.16.8-S1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "9.18.32-S1",
              "status": "affected",
              "version": "9.18.11-S1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "ISC would like to thank Toshifumi Sakaguchi for bringing this vulnerability to our attention."
        }
      ],
      "datePublic": "2025-01-29T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "It is possible to construct a zone such that some queries to it will generate responses containing numerous records in the Additional section. An attacker sending many such queries can cause either the authoritative server itself or an independent resolver to use disproportionate resources processing the queries. Zones will usually need to have been deliberately crafted to attack this exposure.\nThis issue affects BIND 9 versions 9.11.0 through 9.11.37, 9.16.0 through 9.16.50, 9.18.0 through 9.18.32, 9.20.0 through 9.20.4, 9.21.0 through 9.21.3, 9.11.3-S1 through 9.11.37-S1, 9.16.8-S1 through 9.16.50-S1, and 9.18.11-S1 through 9.18.32-S1."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "We are not aware of any active exploits."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "A `named` instance vulnerable to this issue can be compelled to consume excessive CPU resources up to the point where exhaustion of resources effectively prevents the server from responding to other client queries. This issue is most likely to affect resolvers but could also degrade authoritative server performance."
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-405",
              "description": "CWE-405 Asymmetric Resource Consumption (Amplification)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-29T21:40:11.942Z",
        "orgId": "404fd4d2-a609-4245-b543-2c944a302a22",
        "shortName": "isc"
      },
      "references": [
        {
          "name": "CVE-2024-11187",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://kb.isc.org/docs/cve-2024-11187"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade to the patched release most closely related to your current version of BIND 9: 9.18.33, 9.20.5, 9.21.4, or 9.18.33-S1."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Many records in the additional section cause CPU exhaustion",
      "workarounds": [
        {
          "lang": "en",
          "value": "Setting option `minimal-responses yes;` provides an effective workaround."
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "404fd4d2-a609-4245-b543-2c944a302a22",
    "assignerShortName": "isc",
    "cveId": "CVE-2024-11187",
    "datePublished": "2025-01-29T21:40:11.942Z",
    "dateReserved": "2024-11-13T17:20:48.660Z",
    "dateUpdated": "2025-02-11T19:02:32.914Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-11187\",\"sourceIdentifier\":\"security-officer@isc.org\",\"published\":\"2025-01-29T22:15:28.637\",\"lastModified\":\"2025-02-11T19:15:12.640\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"It is possible to construct a zone such that some queries to it will generate responses containing numerous records in the Additional section. An attacker sending many such queries can cause either the authoritative server itself or an independent resolver to use disproportionate resources processing the queries. Zones will usually need to have been deliberately crafted to attack this exposure.\\nThis issue affects BIND 9 versions 9.11.0 through 9.11.37, 9.16.0 through 9.16.50, 9.18.0 through 9.18.32, 9.20.0 through 9.20.4, 9.21.0 through 9.21.3, 9.11.3-S1 through 9.11.37-S1, 9.16.8-S1 through 9.16.50-S1, and 9.18.11-S1 through 9.18.32-S1.\"},{\"lang\":\"es\",\"value\":\"Es posible construir una zona de manera que algunas consultas generen respuestas que contengan numerosos registros en la secci\u00f3n Adicional. Un atacante que env\u00ede muchas consultas de este tipo puede provocar que el servidor autorizado o un solucionador independiente utilicen recursos desproporcionados para procesar las consultas. Por lo general, ser\u00e1 necesario que las zonas hayan sido deliberadamente manipulado para atacar esta exposici\u00f3n. Este problema afecta a las versiones de BIND 9 9.11.0 a 9.11.37, 9.16.0 a 9.16.50, 9.18.0 a 9.18.32, 9.20.0 a 9.20.4, 9.21.0 a 9.21.3, 9.11.3-S1 a 9.11.37-S1, 9.16.8-S1 a 9.16.50-S1 y 9.18.11-S1 a 9.18.32-S1.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security-officer@isc.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"security-officer@isc.org\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-405\"}]}],\"references\":[{\"url\":\"https://kb.isc.org/docs/cve-2024-11187\",\"source\":\"security-officer@isc.org\"},{\"url\":\"https://lists.debian.org/debian-lts-announce/2025/02/msg00011.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://security.netapp.com/advisory/ntap-20250207-0002/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://security.netapp.com/advisory/ntap-20250207-0002/\"}, {\"url\": \"https://lists.debian.org/debian-lts-announce/2025/02/msg00011.html\"}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2025-02-11T19:02:32.914Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-11187\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-30T15:27:46.174106Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-30T15:27:15.557Z\"}}], \"cna\": {\"title\": \"Many records in the additional section cause CPU exhaustion\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"value\": \"ISC would like to thank Toshifumi Sakaguchi for bringing this vulnerability to our attention.\"}], \"impacts\": [{\"descriptions\": [{\"lang\": \"en\", \"value\": \"A `named` instance vulnerable to this issue can be compelled to consume excessive CPU resources up to the point where exhaustion of resources effectively prevents the server from responding to other client queries. This issue is most likely to affect resolvers but could also degrade authoritative server performance.\"}]}], \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}], \"affected\": [{\"vendor\": \"ISC\", \"product\": \"BIND 9\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.11.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.11.37\"}, {\"status\": \"affected\", \"version\": \"9.16.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.16.50\"}, {\"status\": \"affected\", \"version\": \"9.18.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.18.32\"}, {\"status\": \"affected\", \"version\": \"9.20.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.20.4\"}, {\"status\": \"affected\", \"version\": \"9.21.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.21.3\"}, {\"status\": \"affected\", \"version\": \"9.11.3-S1\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.11.37-S1\"}, {\"status\": \"affected\", \"version\": \"9.16.8-S1\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.16.50-S1\"}, {\"status\": \"affected\", \"version\": \"9.18.11-S1\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"9.18.32-S1\"}], \"defaultStatus\": \"unaffected\"}], \"exploits\": [{\"lang\": \"en\", \"value\": \"We are not aware of any active exploits.\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Upgrade to the patched release most closely related to your current version of BIND 9: 9.18.33, 9.20.5, 9.21.4, or 9.18.33-S1.\"}], \"datePublic\": \"2025-01-29T00:00:00.000Z\", \"references\": [{\"url\": \"https://kb.isc.org/docs/cve-2024-11187\", \"name\": \"CVE-2024-11187\", \"tags\": [\"vendor-advisory\"]}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"Setting option `minimal-responses yes;` provides an effective workaround.\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"It is possible to construct a zone such that some queries to it will generate responses containing numerous records in the Additional section. An attacker sending many such queries can cause either the authoritative server itself or an independent resolver to use disproportionate resources processing the queries. Zones will usually need to have been deliberately crafted to attack this exposure.\\nThis issue affects BIND 9 versions 9.11.0 through 9.11.37, 9.16.0 through 9.16.50, 9.18.0 through 9.18.32, 9.20.0 through 9.20.4, 9.21.0 through 9.21.3, 9.11.3-S1 through 9.11.37-S1, 9.16.8-S1 through 9.16.50-S1, and 9.18.11-S1 through 9.18.32-S1.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-405\", \"description\": \"CWE-405 Asymmetric Resource Consumption (Amplification)\"}]}], \"providerMetadata\": {\"orgId\": \"404fd4d2-a609-4245-b543-2c944a302a22\", \"shortName\": \"isc\", \"dateUpdated\": \"2025-01-29T21:40:11.942Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-11187\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-11T19:02:32.914Z\", \"dateReserved\": \"2024-11-13T17:20:48.660Z\", \"assignerOrgId\": \"404fd4d2-a609-4245-b543-2c944a302a22\", \"datePublished\": \"2025-01-29T21:40:11.942Z\", \"assignerShortName\": \"isc\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…