CVE-2024-1180 (GCVE-0-2024-1180)

Vulnerability from cvelistv5 – Published: 2024-04-03 16:30 – Updated: 2024-08-01 18:33
VLAI?
Title
TP-Link Omada ER605 Access Control Command Injection Remote Code Execution Vulnerability
Summary
TP-Link Omada ER605 Access Control Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link Omada ER605. Authentication is required to exploit this vulnerability. The specific issue exists within the handling of the name field in the access control user interface. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-22227.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
zdi
References
Impacted products
Vendor Product Version
TP-Link Omada ER605 Affected: 2.1.2 Build 20230210 Rel.62992
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tp-link:er605:2.1.2_build_20230210:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "er605",
            "vendor": "tp-link",
            "versions": [
              {
                "status": "affected",
                "version": "2.1.2_build_20230210"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-1180",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-06T16:12:54.477242Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T18:00:10.446Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:33:24.167Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "ZDI-24-086",
            "tags": [
              "x_research-advisory",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-086/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Omada ER605",
          "vendor": "TP-Link",
          "versions": [
            {
              "status": "affected",
              "version": "2.1.2 Build 20230210 Rel.62992"
            }
          ]
        }
      ],
      "dateAssigned": "2024-02-01T15:43:51.540-06:00",
      "datePublic": "2024-02-05T17:44:44.659-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "TP-Link Omada ER605 Access Control Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link Omada ER605. Authentication is required to exploit this vulnerability.\n\nThe specific issue exists within the handling of the name field in the access control user interface. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-22227."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-03T16:30:55.786Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-086",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-086/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "Noam Moshe of Claroty Research - Team82"
      },
      "title": "TP-Link Omada ER605 Access Control Command Injection Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-1180",
    "datePublished": "2024-04-03T16:30:55.786Z",
    "dateReserved": "2024-02-01T21:43:17.125Z",
    "dateUpdated": "2024-08-01T18:33:24.167Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "descriptions": "[{\"lang\": \"en\", \"value\": \"TP-Link Omada ER605 Access Control Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link Omada ER605. Authentication is required to exploit this vulnerability.\\n\\nThe specific issue exists within the handling of the name field in the access control user interface. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-22227.\"}, {\"lang\": \"es\", \"value\": \"Vulnerabilidad de ejecuci\\u00f3n remota de c\\u00f3digo de inyecci\\u00f3n de comando de control de acceso TP-Link Omada ER605. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar c\\u00f3digo arbitrario en las instalaciones afectadas de TP-Link Omada ER605. Se requiere autenticaci\\u00f3n para aprovechar esta vulnerabilidad. El problema espec\\u00edfico existe en el manejo del campo de nombre en la interfaz de usuario de control de acceso. El problema se debe a la falta de validaci\\u00f3n adecuada de una cadena proporcionada por el usuario antes de usarla para ejecutar una llamada al SYSTEM. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\\u00f3digo en el contexto de la ra\\u00edz. Era ZDI-CAN-22227.\"}]",
      "id": "CVE-2024-1180",
      "lastModified": "2024-11-21T08:49:58.587",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"zdi-disclosures@trendmicro.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.9, \"impactScore\": 5.9}]}",
      "published": "2024-04-03T17:15:47.530",
      "references": "[{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-24-086/\", \"source\": \"zdi-disclosures@trendmicro.com\"}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-24-086/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
      "sourceIdentifier": "zdi-disclosures@trendmicro.com",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": "[{\"source\": \"zdi-disclosures@trendmicro.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-1180\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2024-04-03T17:15:47.530\",\"lastModified\":\"2025-08-08T18:26:56.050\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"TP-Link Omada ER605 Access Control Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link Omada ER605. Authentication is required to exploit this vulnerability.\\n\\nThe specific issue exists within the handling of the name field in the access control user interface. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-22227.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo de inyecci\u00f3n de comando de control de acceso TP-Link Omada ER605. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de TP-Link Omada ER605. Se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. El problema espec\u00edfico existe en el manejo del campo de nombre en la interfaz de usuario de control de acceso. El problema se debe a la falta de validaci\u00f3n adecuada de una cadena proporcionada por el usuario antes de usarla para ejecutar una llamada al SYSTEM. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto de la ra\u00edz. Era ZDI-CAN-22227.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.0,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.1,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tp-link:omada_er605_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.2.3\",\"matchCriteriaId\":\"8204CA80-BDA7-49C0-9D27-5EB0F388DECC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tp-link:omada_er605:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"47049DE6-9372-41CA-B6AA-969F5E292C9D\"}]}]}],\"references\":[{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-24-086/\",\"source\":\"zdi-disclosures@trendmicro.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-24-086/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-24-086/\", \"name\": \"ZDI-24-086\", \"tags\": [\"x_research-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T18:33:24.167Z\"}}, {\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-1180\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-06T16:12:54.477242Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:tp-link:er605:2.1.2_build_20230210:*:*:*:*:*:*:*\"], \"vendor\": \"tp-link\", \"product\": \"er605\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.1.2_build_20230210\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-06T16:13:48.086Z\"}, \"title\": \"CISA ADP Vulnrichment\"}], \"cna\": {\"title\": \"TP-Link Omada ER605 Access Control Command Injection Remote Code Execution Vulnerability\", \"source\": {\"lang\": \"en\", \"value\": \"Noam Moshe of Claroty Research - Team82\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\"}}], \"affected\": [{\"vendor\": \"TP-Link\", \"product\": \"Omada ER605\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.1.2 Build 20230210 Rel.62992\"}], \"defaultStatus\": \"unknown\"}], \"datePublic\": \"2024-02-05T17:44:44.659-06:00\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-24-086/\", \"name\": \"ZDI-24-086\", \"tags\": [\"x_research-advisory\"]}], \"dateAssigned\": \"2024-02-01T15:43:51.540-06:00\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"TP-Link Omada ER605 Access Control Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link Omada ER605. Authentication is required to exploit this vulnerability.\\n\\nThe specific issue exists within the handling of the name field in the access control user interface. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-22227.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"shortName\": \"zdi\", \"dateUpdated\": \"2024-04-03T16:30:55.786Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-1180\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T18:33:24.167Z\", \"dateReserved\": \"2024-02-01T21:43:17.125Z\", \"assignerOrgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"datePublished\": \"2024-04-03T16:30:55.786Z\", \"assignerShortName\": \"zdi\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…