cve-2024-20767
Vulnerability from cvelistv5
Published
2024-03-18 11:43
Modified
2024-09-13 13:54
Summary
Coldfusion 2023/2021 Pre-Auth monitor uuid leak lead to arbitrary file read/write
Impacted products
AdobeColdFusion
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:adobe:coldfusion:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "affected",
            "product": "coldfusion",
            "vendor": "adobe",
            "versions": [
              {
                "lessThanOrEqual": "2023.0_update_12",
                "status": "affected",
                "version": "2023.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "2021.0_update12",
                "status": "affected",
                "version": "2021.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-20767",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-18T13:26:36.989286Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-13T13:54:13.282Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:59:42.948Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://helpx.adobe.com/security/products/coldfusion/apsb24-14.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "ColdFusion",
          "vendor": "Adobe",
          "versions": [
            {
              "lessThanOrEqual": "2021.12",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-03-12T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "ColdFusion versions 2023.6, 2021.12 and earlier are affected by an Improper Access Control vulnerability that could lead to arbitrary file system read. An attacker could leverage this vulnerability to bypass security measures and gain unauthorized access to sensitive files and perform arbitrary file system write. Exploitation of this issue does not require user interaction."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "environmentalScore": 8.2,
            "environmentalSeverity": "HIGH",
            "exploitCodeMaturity": "NOT_DEFINED",
            "integrityImpact": "LOW",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "LOW",
            "modifiedAttackVector": "NETWORK",
            "modifiedAvailabilityImpact": "NONE",
            "modifiedConfidentialityImpact": "HIGH",
            "modifiedIntegrityImpact": "LOW",
            "modifiedPrivilegesRequired": "NONE",
            "modifiedScope": "NOT_DEFINED",
            "modifiedUserInteraction": "NONE",
            "privilegesRequired": "NONE",
            "remediationLevel": "NOT_DEFINED",
            "reportConfidence": "NOT_DEFINED",
            "scope": "UNCHANGED",
            "temporalScore": 8.2,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "Improper Access Control (CWE-284)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-18T11:43:28.473Z",
        "orgId": "078d4453-3bcd-4900-85e6-15281da43538",
        "shortName": "adobe"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://helpx.adobe.com/security/products/coldfusion/apsb24-14.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Coldfusion 2023/2021 Pre-Auth monitor uuid leak  lead to arbitrary file read/write"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "078d4453-3bcd-4900-85e6-15281da43538",
    "assignerShortName": "adobe",
    "cveId": "CVE-2024-20767",
    "datePublished": "2024-03-18T11:43:28.473Z",
    "dateReserved": "2023-12-04T16:52:22.987Z",
    "dateUpdated": "2024-09-13T13:54:13.282Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-20767\",\"sourceIdentifier\":\"psirt@adobe.com\",\"published\":\"2024-03-18T12:15:06.870\",\"lastModified\":\"2024-03-18T12:38:25.490\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"ColdFusion versions 2023.6, 2021.12 and earlier are affected by an Improper Access Control vulnerability that could lead to arbitrary file system read. An attacker could leverage this vulnerability to bypass security measures and gain unauthorized access to sensitive files and perform arbitrary file system write. Exploitation of this issue does not require user interaction.\"},{\"lang\":\"es\",\"value\":\"Las versiones 2023.6, 2021.12 y anteriores de ColdFusion se ven afectadas por una vulnerabilidad de control de acceso inadecuado que podr\u00eda provocar una lectura arbitraria del sistema de archivos. Un atacante podr\u00eda aprovechar esta vulnerabilidad para eludir las medidas de seguridad y obtener acceso no autorizado a archivos confidenciales y realizar escrituras arbitrarias en el sistema de archivos. La explotaci\u00f3n de este problema no requiere la interacci\u00f3n del usuario.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@adobe.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":4.2}]},\"weaknesses\":[{\"source\":\"psirt@adobe.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"references\":[{\"url\":\"https://helpx.adobe.com/security/products/coldfusion/apsb24-14.html\",\"source\":\"psirt@adobe.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.