CVE-2024-23485 (GCVE-0-2024-23485)

Vulnerability from cvelistv5 – Published: 2024-07-11 02:38 – Updated: 2024-08-01 23:06
VLAI?
Summary
Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation (CWE-1304) in the Controller 6000 and 7000 can lead to secured door locks connected via Aperio Communication Hubs to momentarily allow free access.  This issue affects: Gallagher Controller 6000 and 7000 9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)),  8.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)), 8.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.
CWE
  • CWE-1304 - Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation
Assigner
Impacted products
Vendor Product Version
Gallagher Controller 6000 and Controller 7000 Affected: 9.10 , < vCR9.10.240520a (custom)
Affected: 9.00 , < vCR9.00.240521a (custom)
Affected: 8.90 , < vCR8.90.240520a (custom)
Affected: 8.80 , < vCR8.80.240520a (custom)
Affected: 8.70 , < vCR8.70.240520a (custom)
Affected: 0 , ≤ 8.60 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-23485",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-11T13:52:19.796635Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-11T18:44:04.796Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:06:24.727Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.gallagher.com/Security-Advisories/CVE-2024-23485"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Controller 6000 and Controller 7000",
          "vendor": "Gallagher",
          "versions": [
            {
              "lessThan": "vCR9.10.240520a",
              "status": "affected",
              "version": "9.10",
              "versionType": "custom"
            },
            {
              "lessThan": "vCR9.00.240521a",
              "status": "affected",
              "version": "9.00",
              "versionType": "custom"
            },
            {
              "lessThan": "vCR8.90.240520a",
              "status": "affected",
              "version": "8.90",
              "versionType": "custom"
            },
            {
              "lessThan": "vCR8.80.240520a",
              "status": "affected",
              "version": "8.80",
              "versionType": "custom"
            },
            {
              "lessThan": "vCR8.70.240520a",
              "status": "affected",
              "version": "8.70",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eImproperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation (CWE-1304) in the Controller 6000 and 7000 can lead to secured door locks connected via Aperio Communication Hubs to momentarily allow free access.\u0026nbsp;\u003cbr\u003e\u003cbr\u003e\u003c/span\u003e\u003cb\u003eThis issue affects:\u003c/b\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;Gallagher Controller 6000 and 7000\u0026nbsp;\u003c/span\u003e9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), \u0026nbsp;8.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)),\u0026nbsp;8.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.\n\n"
            }
          ],
          "value": "Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation (CWE-1304) in the Controller 6000 and 7000 can lead to secured door locks connected via Aperio Communication Hubs to momentarily allow free access.\u00a0\n\nThis issue affects:\u00a0Gallagher Controller 6000 and 7000\u00a09.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), \u00a08.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)),\u00a08.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1304",
              "description": "CWE-1304 Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-11T02:38:14.876Z",
        "orgId": "0c426f27-3ee1-4eff-be88-288d5a1822bc",
        "shortName": "Gallagher"
      },
      "references": [
        {
          "url": "https://security.gallagher.com/Security-Advisories/CVE-2024-23485"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0c426f27-3ee1-4eff-be88-288d5a1822bc",
    "assignerShortName": "Gallagher",
    "cveId": "CVE-2024-23485",
    "datePublished": "2024-07-11T02:38:14.876Z",
    "dateReserved": "2024-02-05T04:16:48.001Z",
    "dateUpdated": "2024-08-01T23:06:24.727Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation (CWE-1304) in the Controller 6000 and 7000 can lead to secured door locks connected via Aperio Communication Hubs to momentarily allow free access.\\u00a0\\n\\nThis issue affects:\\u00a0Gallagher Controller 6000 and 7000\\u00a09.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), \\u00a08.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)),\\u00a08.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.\"}, {\"lang\": \"es\", \"value\": \"La integridad preservada inadecuadamente del estado de configuraci\\u00f3n del hardware durante una operaci\\u00f3n de ahorro/restauraci\\u00f3n de energ\\u00eda (CWE-1304) en el controlador 6000 y 7000 puede provocar que puertas cerradas seguras conectadas a trav\\u00e9s de concentradores de comunicaci\\u00f3n Aperio permitan moment\\u00e1neamente el libre acceso. Este problema afecta a: Gallagher Controller 6000 y 7000 9.10 antes de vCR9.10.240520a (distribuido en 9.10.1268(MR1)), 9.00 antes de vCR9.00.240521a (distribuido en 9.00.1990(MR3)), 8.90 antes de vCR8. 90.240520a (distribuido en 8.90.1947 (MR4)), 8.80 antes de vCR8.80.240520a (distribuido en 8.80.1726 (MR5)), 8.70 antes de vCR8.70.240520a (distribuido en 8.70.2824 (MR7)), todos Versiones de 8.60 y anteriores.\"}]",
      "id": "CVE-2024-23485",
      "lastModified": "2024-11-21T08:57:48.497",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"disclosures@gallagher.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 4.6, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"PHYSICAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 0.9, \"impactScore\": 3.6}]}",
      "published": "2024-07-11T03:15:03.327",
      "references": "[{\"url\": \"https://security.gallagher.com/Security-Advisories/CVE-2024-23485\", \"source\": \"disclosures@gallagher.com\"}, {\"url\": \"https://security.gallagher.com/Security-Advisories/CVE-2024-23485\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
      "sourceIdentifier": "disclosures@gallagher.com",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": "[{\"source\": \"disclosures@gallagher.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-1304\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-23485\",\"sourceIdentifier\":\"disclosures@gallagher.com\",\"published\":\"2024-07-11T03:15:03.327\",\"lastModified\":\"2024-11-21T08:57:48.497\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation (CWE-1304) in the Controller 6000 and 7000 can lead to secured door locks connected via Aperio Communication Hubs to momentarily allow free access.\u00a0\\n\\nThis issue affects:\u00a0Gallagher Controller 6000 and 7000\u00a09.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), \u00a08.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)),\u00a08.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.\"},{\"lang\":\"es\",\"value\":\"La integridad preservada inadecuadamente del estado de configuraci\u00f3n del hardware durante una operaci\u00f3n de ahorro/restauraci\u00f3n de energ\u00eda (CWE-1304) en el controlador 6000 y 7000 puede provocar que puertas cerradas seguras conectadas a trav\u00e9s de concentradores de comunicaci\u00f3n Aperio permitan moment\u00e1neamente el libre acceso. Este problema afecta a: Gallagher Controller 6000 y 7000 9.10 antes de vCR9.10.240520a (distribuido en 9.10.1268(MR1)), 9.00 antes de vCR9.00.240521a (distribuido en 9.00.1990(MR3)), 8.90 antes de vCR8. 90.240520a (distribuido en 8.90.1947 (MR4)), 8.80 antes de vCR8.80.240520a (distribuido en 8.80.1726 (MR5)), 8.70 antes de vCR8.70.240520a (distribuido en 8.70.2824 (MR7)), todos Versiones de 8.60 y anteriores.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"disclosures@gallagher.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":4.6,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"disclosures@gallagher.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1304\"}]}],\"references\":[{\"url\":\"https://security.gallagher.com/Security-Advisories/CVE-2024-23485\",\"source\":\"disclosures@gallagher.com\"},{\"url\":\"https://security.gallagher.com/Security-Advisories/CVE-2024-23485\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://security.gallagher.com/Security-Advisories/CVE-2024-23485\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T23:06:24.727Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-23485\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-11T13:52:19.796635Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-11T13:52:27.845Z\"}}], \"cna\": {\"source\": {\"discovery\": \"INTERNAL\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.6, \"attackVector\": \"PHYSICAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Gallagher\", \"product\": \"Controller 6000 and Controller 7000\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.10\", \"lessThan\": \"vCR9.10.240520a\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"9.00\", \"lessThan\": \"vCR9.00.240521a\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"8.90\", \"lessThan\": \"vCR8.90.240520a\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"8.80\", \"lessThan\": \"vCR8.80.240520a\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"8.70\", \"lessThan\": \"vCR8.70.240520a\", \"versionType\": \"custom\"}, {\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"8.60\"}], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://security.gallagher.com/Security-Advisories/CVE-2024-23485\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation (CWE-1304) in the Controller 6000 and 7000 can lead to secured door locks connected via Aperio Communication Hubs to momentarily allow free access.\\u00a0\\n\\nThis issue affects:\\u00a0Gallagher Controller 6000 and 7000\\u00a09.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), \\u00a08.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)),\\u00a08.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eImproperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation (CWE-1304) in the Controller 6000 and 7000 can lead to secured door locks connected via Aperio Communication Hubs to momentarily allow free access.\u0026nbsp;\u003cbr\u003e\u003cbr\u003e\u003c/span\u003e\u003cb\u003eThis issue affects:\u003c/b\u003e\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\u0026nbsp;Gallagher Controller 6000 and 7000\u0026nbsp;\u003c/span\u003e9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), \u0026nbsp;8.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)),\u0026nbsp;8.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1304\", \"description\": \"CWE-1304 Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation\"}]}], \"providerMetadata\": {\"orgId\": \"0c426f27-3ee1-4eff-be88-288d5a1822bc\", \"shortName\": \"Gallagher\", \"dateUpdated\": \"2024-07-11T02:38:14.876Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-23485\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T23:06:24.727Z\", \"dateReserved\": \"2024-02-05T04:16:48.001Z\", \"assignerOrgId\": \"0c426f27-3ee1-4eff-be88-288d5a1822bc\", \"datePublished\": \"2024-07-11T02:38:14.876Z\", \"assignerShortName\": \"Gallagher\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…