cve-2024-23784
Vulnerability from cvelistv5
Published
2024-02-14 10:05
Modified
2024-08-15 12:40
Severity ?
EPSS score ?
Summary
Improper access control vulnerability exists in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier, which may allow a network-adjacent unauthenticated attacker to obtain a username and its hashed password displayed on the management page of the affected product.
References
▼ | URL | Tags | |
---|---|---|---|
vultures@jpcert.or.jp | https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf | Vendor Advisory | |
vultures@jpcert.or.jp | https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf | Vendor Advisory | |
vultures@jpcert.or.jp | https://jvn.jp/en/vu/JVNVU94591337/ | Third Party Advisory |
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | SHARP CORPORATION | Energy Management Controller with Cloud Services |
Version: JH-RVB1 Ver.B0.1.9.1 and earlier |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T23:13:08.203Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf" }, { "tags": [ "x_transferred" ], "url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/en/vu/JVNVU94591337/" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2024-23784", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-15T12:40:30.854736Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-15T12:40:39.687Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Energy Management Controller with Cloud Services", "vendor": "SHARP CORPORATION", "versions": [ { "status": "affected", "version": "JH-RVB1 Ver.B0.1.9.1 and earlier" } ] }, { "product": "Energy Management Controller with Cloud Services", "vendor": "SHARP CORPORATION", "versions": [ { "status": "affected", "version": "JH-RV11 Ver.B0.1.9.1 and earlier" } ] } ], "descriptions": [ { "lang": "en", "value": "Improper access control vulnerability exists in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier, which may allow a network-adjacent unauthenticated attacker to obtain a username and its hashed password displayed on the management page of the affected product." } ], "problemTypes": [ { "descriptions": [ { "description": "Improper access control", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-02-14T10:05:55.231Z", "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "shortName": "jpcert" }, "references": [ { "url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf" }, { "url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf" }, { "url": "https://jvn.jp/en/vu/JVNVU94591337/" } ] } }, "cveMetadata": { "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "assignerShortName": "jpcert", "cveId": "CVE-2024-23784", "datePublished": "2024-02-14T10:05:55.231Z", "dateReserved": "2024-01-22T09:56:37.454Z", "dateUpdated": "2024-08-15T12:40:39.687Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-23784\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2024-02-14T10:15:08.610\",\"lastModified\":\"2024-10-17T15:14:57.060\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper access control vulnerability exists in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier, which may allow a network-adjacent unauthenticated attacker to obtain a username and its hashed password displayed on the management page of the affected product.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de control de acceso inadecuado en Energy Management Controller con servicios en la nube JH-RVB1 /JH-RV11 Ver.B0.1.9.1 y anteriores, lo que puede permitir a un atacante no autenticado adyacente a la red obtener un nombre de usuario y su contrase\u00f1a hash que se muestran en la p\u00e1gina de administraci\u00f3n del producto afectado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sharp:jh-rvb1_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"b0.1.9.1\",\"matchCriteriaId\":\"B7EC16DF-21FB-473F-8F62-DDBF1C149A9B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sharp:jh-rvb1:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AE2814EB-D067-4920-A450-4F90431EA461\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sharp:jh-rv11_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"b0.1.9.1\",\"matchCriteriaId\":\"E0A2340C-A0BC-4DD5-A120-F7041D76D776\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sharp:jh-rv11:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C13F6906-8ED6-40DE-8B18-260B7765C4A9\"}]}]}],\"references\":[{\"url\":\"https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://jvn.jp/en/vu/JVNVU94591337/\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.