cve-2024-27173
Vulnerability from cvelistv5
Published
2024-06-14 04:01
Modified
2024-08-02 00:27
Severity ?
Summary
insecure upload
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27173",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-17T15:49:44.144208Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-17T15:50:30.057Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:27:59.671Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.toshibatec.com/information/20240531_01.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.toshibatec.com/information/pdf/information20240531_01.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU97136265/index.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2024/Jul/1"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "Toshiba Tec e-Studio multi-function peripheral (MFP)",
          "vendor": "Toshiba Tec Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "see the reference URL"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "We expresses its gratitude to Pierre Barre for reporting relevant security vulnerabilities for our products."
        }
      ],
      "datePublic": "2024-06-14T02:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Remote Command program allows an attacker to get Remote Code Execution by overwriting existing Python files containing executable code.\u0026nbsp;This vulnerability can be executed in combination with other vulnerabilities and  difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the \"Base Score\" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.toshibatec.com/contacts/products/\"\u003ehttps://www.toshibatec.com/contacts/products/\u003c/a\u003e\u003cbr\u003eAs for the affected products/models/versions, see the reference URL."
            }
          ],
          "value": "Remote Command program allows an attacker to get Remote Code Execution by overwriting existing Python files containing executable code.\u00a0This vulnerability can be executed in combination with other vulnerabilities and  difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the \"Base Score\" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.\n https://www.toshibatec.com/contacts/products/ \nAs for the affected products/models/versions, see the reference URL."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "We are not aware of any malicious exploitation by these vulnerabilities.\u003cbr\u003e"
            }
          ],
          "value": "We are not aware of any malicious exploitation by these vulnerabilities."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-126",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-126 Path Traversal"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-14T04:01:54.119Z",
        "orgId": "ecc0f906-8666-484c-bcf8-c3b7520a72f0",
        "shortName": "Toshiba"
      },
      "references": [
        {
          "url": "https://www.toshibatec.com/information/20240531_01.html"
        },
        {
          "url": "https://www.toshibatec.com/information/pdf/information20240531_01.pdf"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU97136265/index.html"
        },
        {
          "url": "http://seclists.org/fulldisclosure/2024/Jul/1"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This issue is fixed in the version released on June 14, 2024 and all later versions.\u003cbr\u003e"
            }
          ],
          "value": "This issue is fixed in the version released on June 14, 2024 and all later versions."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "timeline": [
        {
          "lang": "en",
          "time": "2024-06-14T02:00:00.000Z",
          "value": "Fixes will be released"
        }
      ],
      "title": "insecure upload",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "When connecting the MFPs and printers with an outer network such as the Internet, only operate it in a network environment protected by a firewall, etc. to prevent information from being leaked due to incorrect settings or avoid illegal access by unauthorized users.\u003cbr\u003e"
            }
          ],
          "value": "When connecting the MFPs and printers with an outer network such as the Internet, only operate it in a network environment protected by a firewall, etc. to prevent information from being leaked due to incorrect settings or avoid illegal access by unauthorized users."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ecc0f906-8666-484c-bcf8-c3b7520a72f0",
    "assignerShortName": "Toshiba",
    "cveId": "CVE-2024-27173",
    "datePublished": "2024-06-14T04:01:54.119Z",
    "dateReserved": "2024-02-21T02:12:01.820Z",
    "dateUpdated": "2024-08-02T00:27:59.671Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-27173\",\"sourceIdentifier\":\"ecc0f906-8666-484c-bcf8-c3b7520a72f0\",\"published\":\"2024-06-14T04:15:36.540\",\"lastModified\":\"2024-07-04T05:15:14.670\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Remote Command program allows an attacker to get Remote Code Execution by overwriting existing Python files containing executable code.\u00a0This vulnerability can be executed in combination with other vulnerabilities and  difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the \\\"Base Score\\\" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.\\n https://www.toshibatec.com/contacts/products/ \\nAs for the affected products/models/versions, see the reference URL.\"},{\"lang\":\"es\",\"value\":\"El programa Remote Command permite a un atacante obtener la ejecuci\u00f3n remota de c\u00f3digo sobrescribiendo archivos Python existentes que contienen c\u00f3digo ejecutable. Esta vulnerabilidad se puede ejecutar en combinaci\u00f3n con otras vulnerabilidades y es dif\u00edcil de ejecutar sola. Por lo tanto, la puntuaci\u00f3n CVSS para esta vulnerabilidad por s\u00ed sola es inferior a la puntuaci\u00f3n que figura en la \\\"Puntuaci\u00f3n base\\\" de esta vulnerabilidad. Para obtener detalles sobre otras vulnerabilidades relacionadas, consulte al siguiente punto de contacto. https://www.toshibatec.com/contacts/products/ En cuanto a los productos/modelos/versiones afectados, consulte la URL de referencia.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ecc0f906-8666-484c-bcf8-c3b7520a72f0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ecc0f906-8666-484c-bcf8-c3b7520a72f0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"references\":[{\"url\":\"http://seclists.org/fulldisclosure/2024/Jul/1\",\"source\":\"ecc0f906-8666-484c-bcf8-c3b7520a72f0\"},{\"url\":\"https://jvn.jp/en/vu/JVNVU97136265/index.html\",\"source\":\"ecc0f906-8666-484c-bcf8-c3b7520a72f0\"},{\"url\":\"https://www.toshibatec.com/information/20240531_01.html\",\"source\":\"ecc0f906-8666-484c-bcf8-c3b7520a72f0\"},{\"url\":\"https://www.toshibatec.com/information/pdf/information20240531_01.pdf\",\"source\":\"ecc0f906-8666-484c-bcf8-c3b7520a72f0\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.