cve-2024-28162
Vulnerability from cvelistv5
Published
2024-03-06 17:02
Modified
2024-08-02 00:48
Severity
Summary
In Jenkins Delphix Plugin 3.0.1 through 3.1.0 (both inclusive) a global option for administrators to enable or disable SSL/TLS certificate validation for Data Control Tower (DCT) connections fails to take effect until Jenkins is restarted when switching from disabled validation to enabled validation.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-28162",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-07T16:28:35.423603Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T18:03:09.469Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:48:49.411Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "Jenkins Security Advisory 2024-03-06",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.jenkins.io/security/advisory/2024-03-06/#SECURITY-3330"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2024/03/06/3"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Jenkins Delphix Plugin",
          "vendor": "Jenkins Project",
          "versions": [
            {
              "lessThanOrEqual": "3.1.0",
              "status": "affected",
              "version": "3.0.1",
              "versionType": "maven"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Jenkins Delphix Plugin 3.0.1 through 3.1.0 (both inclusive) a global option for administrators to enable or disable SSL/TLS certificate validation for Data Control Tower (DCT) connections fails to take effect until Jenkins is restarted when switching from disabled validation to enabled validation."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-06T17:02:02.667Z",
        "orgId": "39769cd5-e6e2-4dc8-927e-97b3aa056f5b",
        "shortName": "jenkins"
      },
      "references": [
        {
          "name": "Jenkins Security Advisory 2024-03-06",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.jenkins.io/security/advisory/2024-03-06/#SECURITY-3330"
        },
        {
          "url": "http://www.openwall.com/lists/oss-security/2024/03/06/3"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "39769cd5-e6e2-4dc8-927e-97b3aa056f5b",
    "assignerShortName": "jenkins",
    "cveId": "CVE-2024-28162",
    "datePublished": "2024-03-06T17:02:02.667Z",
    "dateReserved": "2024-03-05T19:29:05.205Z",
    "dateUpdated": "2024-08-02T00:48:49.411Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-28162\",\"sourceIdentifier\":\"jenkinsci-cert@googlegroups.com\",\"published\":\"2024-03-06T17:15:11.140\",\"lastModified\":\"2024-05-01T18:15:17.223\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Jenkins Delphix Plugin 3.0.1 through 3.1.0 (both inclusive) a global option for administrators to enable or disable SSL/TLS certificate validation for Data Control Tower (DCT) connections fails to take effect until Jenkins is restarted when switching from disabled validation to enabled validation.\"},{\"lang\":\"es\",\"value\":\"En Jenkins Delphix Plugin 3.0.1 a 3.1.0 (ambos inclusive), una opci\u00f3n global para que los administradores habiliten o deshabiliten la validaci\u00f3n de certificados SSL/TLS para conexiones de la Torre de control de datos (DCT) no surte efecto hasta que se reinicia al cambiar de validaci\u00f3n deshabilitada a validaci\u00f3n habilitada.\"}],\"metrics\":{},\"references\":[{\"url\":\"http://www.openwall.com/lists/oss-security/2024/03/06/3\",\"source\":\"jenkinsci-cert@googlegroups.com\"},{\"url\":\"https://www.jenkins.io/security/advisory/2024-03-06/#SECURITY-3330\",\"source\":\"jenkinsci-cert@googlegroups.com\"}]}}"
  }
}


Log in or create an account to share your comment.