cve-2024-32850
Vulnerability from cvelistv5
Published
2024-05-31 01:33
Modified
2024-08-02 02:20
Severity
9.8 (Critical) - cvssV3_1 - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "skybridge_basic_mb-a130_firmware",
            "vendor": "seiko-sol",
            "versions": [
              {
                "lessThanOrEqual": "1.5.5",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "skybridge_mb-a110_firmware",
            "vendor": "seiko-sol",
            "versions": [
              {
                "lessThanOrEqual": "4.2.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-32850",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-31T16:32:25.573045Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-78",
                "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-05T20:01:12.070Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:20:35.662Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.seiko-sol.co.jp/archives/82992/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU94872523/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SkyBridge MB-A100/MB-A110",
          "vendor": "Seiko Solutions Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware Ver. 4.2.2 and earlier"
            }
          ]
        },
        {
          "product": "SkyBridge BASIC MB-A130",
          "vendor": "Seiko Solutions Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware Ver. 1.5.5 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper neutralization of special elements used in a command (\u0027Command Injection\u0027) exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-31T01:33:32.849Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.seiko-sol.co.jp/archives/82992/"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU94872523/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-32850",
    "datePublished": "2024-05-31T01:33:32.849Z",
    "dateReserved": "2024-04-19T05:24:47.944Z",
    "dateUpdated": "2024-08-02T02:20:35.662Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-32850\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2024-05-31T02:15:08.843\",\"lastModified\":\"2024-07-03T01:57:09.843\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper neutralization of special elements used in a command (\u0027Command Injection\u0027) exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.\"},{\"lang\":\"es\",\"value\":\"Existe una neutralizaci\u00f3n inadecuada de elementos especiales utilizados en un comando (\\\"Inyecci\u00f3n de comando\\\") en la versi\u00f3n del firmware SkyBridge MB-A100/MB-A110 4.2.2 y anteriores y el firmware SkyBridge BASIC MB-A130 Ver. 1.5.5 y anteriores. Si la funci\u00f3n de control y supervisi\u00f3n remota est\u00e1 habilitada en el producto, un atacante con acceso al producto puede ejecutar un comando arbitrario o iniciar sesi\u00f3n en el producto con privilegios de administrador.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://jvn.jp/en/vu/JVNVU94872523/\",\"source\":\"vultures@jpcert.or.jp\"},{\"url\":\"https://www.seiko-sol.co.jp/archives/82992/\",\"source\":\"vultures@jpcert.or.jp\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...