Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    25 vulnerabilities by Seiko Solutions Inc.

    JVNDB-2025-000068

    Vulnerability from jvndb - Published: 2025-09-01 16:21 - Updated:2025-09-01 16:21
    Severity
    Summary
    Seiko Solutions SkyBridge BASIC MB-A130 vulnerable to OS command injection
    Details
    SkyBridge BASIC MB-A130 provided by Seiko Solutions Inc. contains the following vulnerability.
    • OS command injection (CWE-78) - CVE-2025-54857
    Tsutomu Aramaki of Mitsui Bussan Secure Directions, Inc. reported this vulnerability to IPA. JPCERT/CC coordinated with the developer under Information Security Early Warning Partnership.
    Show details on JVN DB website

    {
      "@rdf:about": "https://jvndb.jvn.jp/en/contents/2025/JVNDB-2025-000068.html",
      "dc:date": "2025-09-01T16:21+09:00",
      "dcterms:issued": "2025-09-01T16:21+09:00",
      "dcterms:modified": "2025-09-01T16:21+09:00",
      "description": "SkyBridge BASIC MB-A130 provided by Seiko Solutions Inc. contains the following vulnerability.\r\n\r\n\u003cul\u003e\u003cli\u003eOS command injection (CWE-78) - CVE-2025-54857\u003c/li\u003e\u003c/ul\u003e\r\nTsutomu Aramaki of Mitsui Bussan Secure Directions, Inc. reported this vulnerability to IPA.\r\nJPCERT/CC coordinated with the developer under Information Security Early Warning Partnership.",
      "link": "https://jvndb.jvn.jp/en/contents/2025/JVNDB-2025-000068.html",
      "sec:cpe": {
        "#text": "cpe:/o:seiko-sol:skybridge_basic_mb-a130_firmware",
        "@product": "SkyBridge BASIC MB-A130 firmware",
        "@vendor": "Seiko Solutions Inc.",
        "@version": "2.2"
      },
      "sec:cvss": {
        "@score": "9.8",
        "@severity": "Critical",
        "@type": "Base",
        "@vector": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
        "@version": "3.0"
      },
      "sec:identifier": "JVNDB-2025-000068",
      "sec:references": [
        {
          "#text": "https://jvn.jp/en/jp/JVN22016482/index.html",
          "@id": "JVN#22016482",
          "@source": "JVN"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2025-54857",
          "@id": "CVE-2025-54857",
          "@source": "CVE"
        },
        {
          "#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
          "@id": "CWE-78",
          "@title": "OS Command Injection(CWE-78)"
        }
      ],
      "title": "Seiko Solutions SkyBridge BASIC MB-A130 vulnerable to OS command injection"
    }

    JVNDB-2024-003254

    Vulnerability from jvndb - Published: 2024-06-03 14:53 - Updated:2024-06-03 14:53
    Severity
    Summary
    Seiko Solutions SkyBridge MB-A100/MB-A110 and SkyBridge BASIC MB-A130 vulnerable to OS command injection
    Details
    SkyBridge MB-A100/MB-A110 and SkyBridge BASIC MB-A130 provided by Seiko Solutions Inc. contain a command injection vulnerability (CWE-77). Chuya Hayakawa of 00One, Inc. reported this vulnerability to JPCERT/CC. JPCERT/CC coordinated with the developer.
    Show details on JVN DB website

    {
      "@rdf:about": "https://jvndb.jvn.jp/en/contents/2024/JVNDB-2024-003254.html",
      "dc:date": "2024-06-03T14:53+09:00",
      "dcterms:issued": "2024-06-03T14:53+09:00",
      "dcterms:modified": "2024-06-03T14:53+09:00",
      "description": "SkyBridge MB-A100/MB-A110 and SkyBridge BASIC MB-A130 provided by Seiko Solutions Inc. contain a command injection vulnerability (CWE-77).\r\n\r\nChuya Hayakawa of 00One, Inc. reported this vulnerability to JPCERT/CC.\r\nJPCERT/CC coordinated with the developer.",
      "link": "https://jvndb.jvn.jp/en/contents/2024/JVNDB-2024-003254.html",
      "sec:cpe": [
        {
          "#text": "cpe:/o:seiko-sol:skybridge_basic_mb-a130_firmware",
          "@product": "SkyBridge BASIC MB-A130 firmware",
          "@vendor": "Seiko Solutions Inc.",
          "@version": "2.2"
        },
        {
          "#text": "cpe:/o:seiko-sol:skybridge_mb-a100_firmware",
          "@product": "SkyBridge MB-A100 firmware",
          "@vendor": "Seiko Solutions Inc.",
          "@version": "2.2"
        },
        {
          "#text": "cpe:/o:seiko-sol:skybridge_mb-a110_firmware",
          "@product": "SkyBridge MB-A110 firmware",
          "@vendor": "Seiko Solutions Inc.",
          "@version": "2.2"
        }
      ],
      "sec:cvss": {
        "@score": "9.8",
        "@severity": "Critical",
        "@type": "Base",
        "@vector": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
        "@version": "3.0"
      },
      "sec:identifier": "JVNDB-2024-003254",
      "sec:references": [
        {
          "#text": "https://jvn.jp/en/vu/JVNVU94872523/index.html",
          "@id": "JVNVU#94872523",
          "@source": "JVN"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2024-32850",
          "@id": "CVE-2024-32850",
          "@source": "CVE"
        },
        {
          "#text": "https://cwe.mitre.org/data/definitions/77.html",
          "@id": "CWE-77",
          "@title": "Command Injection(CWE-77)"
        }
      ],
      "title": "Seiko Solutions SkyBridge MB-A100/MB-A110 and SkyBridge BASIC MB-A130 vulnerable to OS command injection"
    }

    JVNDB-2023-000029

    Vulnerability from jvndb - Published: 2023-03-31 15:54 - Updated:2024-05-27 17:08
    Severity
    Summary
    Multiple vulnerabilities in Seiko Solutions SkyBridge MB-A100/A110/A200/A130 SkySpider MB-R210
    Details
    SkyBridge MB-A100/A110/A200/A130 SkySpider MB-R210 provided by Seiko Solutions Inc. contain multiple vulnerabilities listed below.
    • Exposure of sensitive information to an unauthorized actor (CWE-200) - CVE-2016-2183
    • Command injection (CWE-77) - CVE-2022-36556
    • Unrestricted upload of file with dangerous type (CWE-434) - CVE-2022-36557
    • Use of hard-coded credentials (CWE-798) - CVE-2022-36558
    • Command injection (CWE-77) - CVE-2022-36559
    • Use of hard-coded credentials (CWE-798) - CVE-2022-36560
    • Improper privilege management (CWE-269) - CVE-2023-22361
    • Missing authentication for critical function (CWE-306) - CVE-2023-22441
    • Improper access control (CWE-284) - CVE-2023-23578
    • Improper following of a certificate's chain of trust (CWE-296) - CVE-2023-23901
    • Missing authentication for critical function (CWE-306) - CVE-2023-23906
    • Cleartext storage of sensitive information (CWE-312) - CVE-2023-24586
    • Cleartext transmission of sensitive information (CWE-319) - CVE-2023-25070
    • Use of weak credentials (CWE-1391) - CVE-2023-25072
    • Use of weak credentials (CWE-1391) - CVE-2023-25184
    The developer states that attacks exploiting CVE-2022-36556 have been observed. CVE-2023-22441 MASAHIRO IIDA of LAC Co., Ltd. reported this vulnerability to IPA. JPCERT/CC coordinated with the developer under Information Security Early Warning Partnership. CVE-2016-2183, CVE-2022-36556, CVE-2022-36557, CVE-2022-36558, CVE-2022-36559, CVE-2022-36560, CVE-2023-22361, CVE-2023-23578, CVE-2023-23901, CVE-2023-23906, CVE-2023-24586, CVE-2023-25070, CVE-2023-25072, CVE-2023-25184 Thomas J. Knudsen and Samy Younsi of NeroTeam Security Labs reported these vulnerabilities to JPCERT/CC. JPCERT/CC coordinated with the developer.
    References
    JVN http://jvn.jp/en/jp/JVN40604023/index.html
    CVE https://www.cve.org/CVERecord?id=CVE-2023-22361
    CVE https://www.cve.org/CVERecord?id=CVE-2023-22441
    CVE https://www.cve.org/CVERecord?id=CVE-2023-23578
    CVE https://www.cve.org/CVERecord?id=CVE-2023-23901
    CVE https://www.cve.org/CVERecord?id=CVE-2023-23906
    CVE https://www.cve.org/CVERecord?id=CVE-2023-24586
    CVE https://www.cve.org/CVERecord?id=CVE-2023-25070
    CVE https://www.cve.org/CVERecord?id=CVE-2023-25072
    CVE https://www.cve.org/CVERecord?id=CVE-2023-25184
    CVE https://www.cve.org/CVERecord?id=CVE-2016-2183
    CVE https://www.cve.org/CVERecord?id=CVE-2022-36556
    CVE https://www.cve.org/CVERecord?id=CVE-2022-36557
    CVE https://www.cve.org/CVERecord?id=CVE-2022-36558
    CVE https://www.cve.org/CVERecord?id=CVE-2022-36559
    CVE https://www.cve.org/CVERecord?id=CVE-2022-36560
    NVD https://nvd.nist.gov/vuln/detail/CVE-2016-2183
    NVD https://nvd.nist.gov/vuln/detail/CVE-2022-36556
    NVD https://nvd.nist.gov/vuln/detail/CVE-2022-36557
    NVD https://nvd.nist.gov/vuln/detail/CVE-2022-36558
    NVD https://nvd.nist.gov/vuln/detail/CVE-2022-36559
    NVD https://nvd.nist.gov/vuln/detail/CVE-2022-36560
    NVD https://nvd.nist.gov/vuln/detail/CVE-2023-22361
    NVD https://nvd.nist.gov/vuln/detail/CVE-2023-22441
    NVD https://nvd.nist.gov/vuln/detail/CVE-2023-23578
    NVD https://nvd.nist.gov/vuln/detail/CVE-2023-23901
    NVD https://nvd.nist.gov/vuln/detail/CVE-2023-23906
    NVD https://nvd.nist.gov/vuln/detail/CVE-2023-24586
    NVD https://nvd.nist.gov/vuln/detail/CVE-2023-25070
    NVD https://nvd.nist.gov/vuln/detail/CVE-2023-25072
    NVD https://nvd.nist.gov/vuln/detail/CVE-2023-25184
    Information Exposure(CWE-200) https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html
    Permissions(CWE-264) https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html
    Improper Authentication(CWE-287) https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html
    No Mapping(CWE-Other) https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html
    Show details on JVN DB website

    {
      "@rdf:about": "https://jvndb.jvn.jp/en/contents/2023/JVNDB-2023-000029.html",
      "dc:date": "2024-05-27T17:08+09:00",
      "dcterms:issued": "2023-03-31T15:54+09:00",
      "dcterms:modified": "2024-05-27T17:08+09:00",
      "description": "SkyBridge MB-A100/A110/A200/A130 SkySpider MB-R210 provided by Seiko Solutions Inc. contain multiple vulnerabilities listed below.\r\n\u003cul\u003e\r\n\u003cli\u003eExposure of sensitive information to an unauthorized actor (CWE-200) - CVE-2016-2183\r\n\u003cli\u003eCommand injection (CWE-77) - CVE-2022-36556\r\n\u003cli\u003eUnrestricted upload of file with dangerous type (CWE-434) - CVE-2022-36557\r\n\u003cli\u003eUse of hard-coded credentials (CWE-798) - CVE-2022-36558\r\n\u003cli\u003eCommand injection (CWE-77) - CVE-2022-36559\r\n\u003cli\u003eUse of hard-coded credentials (CWE-798) - CVE-2022-36560\r\n\u003cli\u003eImproper privilege management (CWE-269) - CVE-2023-22361\r\n\u003cli\u003eMissing authentication for critical function (CWE-306) - CVE-2023-22441\r\n\u003cli\u003eImproper access control (CWE-284) - CVE-2023-23578\r\n\u003cli\u003eImproper following of a certificate\u0027s chain of trust (CWE-296) - CVE-2023-23901\r\n\u003cli\u003eMissing authentication for critical function (CWE-306) - CVE-2023-23906\r\n\u003cli\u003eCleartext storage of sensitive information (CWE-312) - CVE-2023-24586\r\n\u003cli\u003eCleartext transmission of sensitive information (CWE-319) - CVE-2023-25070\r\n\u003cli\u003eUse of weak credentials (CWE-1391) - CVE-2023-25072\r\n\u003cli\u003eUse of weak credentials (CWE-1391) - CVE-2023-25184\r\n\u003c/ul\u003e\r\nThe developer states that attacks exploiting CVE-2022-36556 have been observed.\r\n\r\n\r\nCVE-2023-22441\r\nMASAHIRO IIDA of LAC Co., Ltd. reported this vulnerability to IPA.\r\nJPCERT/CC coordinated with the developer under Information Security Early Warning Partnership.\r\n\r\nCVE-2016-2183, CVE-2022-36556, CVE-2022-36557, CVE-2022-36558, CVE-2022-36559, CVE-2022-36560, CVE-2023-22361, CVE-2023-23578, CVE-2023-23901, CVE-2023-23906, CVE-2023-24586, CVE-2023-25070, CVE-2023-25072, CVE-2023-25184\r\nThomas J. Knudsen and Samy Younsi of NeroTeam Security Labs reported these vulnerabilities to JPCERT/CC.\r\nJPCERT/CC coordinated with the developer.",
      "link": "https://jvndb.jvn.jp/en/contents/2023/JVNDB-2023-000029.html",
      "sec:cpe": [
        {
          "#text": "cpe:/o:seiko-sol:skybridge_basic_mb-a130_firmware",
          "@product": "SkyBridge BASIC MB-A130 firmware",
          "@vendor": "Seiko Solutions Inc.",
          "@version": "2.2"
        },
        {
          "#text": "cpe:/o:seiko-sol:skybridge_mb-a100_firmware",
          "@product": "SkyBridge MB-A100 firmware",
          "@vendor": "Seiko Solutions Inc.",
          "@version": "2.2"
        },
        {
          "#text": "cpe:/o:seiko-sol:skybridge_mb-a110_firmware",
          "@product": "SkyBridge MB-A110 firmware",
          "@vendor": "Seiko Solutions Inc.",
          "@version": "2.2"
        },
        {
          "#text": "cpe:/o:seiko-sol:skybridge_mb-a200_firmware",
          "@product": "SkyBridge MB-A200 firmware",
          "@vendor": "Seiko Solutions Inc.",
          "@version": "2.2"
        },
        {
          "#text": "cpe:/o:seiko-sol:skyspider_mb-r210_firmware",
          "@product": "SkySpider MB-R210 firmware",
          "@vendor": "Seiko Solutions Inc.",
          "@version": "2.2"
        }
      ],
      "sec:cvss": [
        {
          "@score": "9.0",
          "@severity": "High",
          "@type": "Base",
          "@vector": "AV:N/AC:L/Au:N/C:P/I:P/A:C",
          "@version": "2.0"
        },
        {
          "@score": "8.6",
          "@severity": "High",
          "@type": "Base",
          "@vector": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
          "@version": "3.0"
        }
      ],
      "sec:identifier": "JVNDB-2023-000029",
      "sec:references": [
        {
          "#text": "http://jvn.jp/en/jp/JVN40604023/index.html",
          "@id": "JVN#40604023",
          "@source": "JVN"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2023-22361",
          "@id": "CVE-2023-22361",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2023-22441",
          "@id": "CVE-2023-22441",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2023-23578",
          "@id": "CVE-2023-23578",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2023-23901",
          "@id": "CVE-2023-23901",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2023-23906",
          "@id": "CVE-2023-23906",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2023-24586",
          "@id": "CVE-2023-24586",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2023-25070",
          "@id": "CVE-2023-25070",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2023-25072",
          "@id": "CVE-2023-25072",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2023-25184",
          "@id": "CVE-2023-25184",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2016-2183",
          "@id": "CVE-2016-2183",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2022-36556",
          "@id": "CVE-2022-36556",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2022-36557",
          "@id": "CVE-2022-36557",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2022-36558",
          "@id": "CVE-2022-36558",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2022-36559",
          "@id": "CVE-2022-36559",
          "@source": "CVE"
        },
        {
          "#text": "https://www.cve.org/CVERecord?id=CVE-2022-36560",
          "@id": "CVE-2022-36560",
          "@source": "CVE"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2016-2183",
          "@id": "CVE-2016-2183",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2022-36556",
          "@id": "CVE-2022-36556",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2022-36557",
          "@id": "CVE-2022-36557",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2022-36558",
          "@id": "CVE-2022-36558",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2022-36559",
          "@id": "CVE-2022-36559",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2022-36560",
          "@id": "CVE-2022-36560",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-22361",
          "@id": "CVE-2023-22361",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-22441",
          "@id": "CVE-2023-22441",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-23578",
          "@id": "CVE-2023-23578",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-23901",
          "@id": "CVE-2023-23901",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-23906",
          "@id": "CVE-2023-23906",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-24586",
          "@id": "CVE-2023-24586",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-25070",
          "@id": "CVE-2023-25070",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-25072",
          "@id": "CVE-2023-25072",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-25184",
          "@id": "CVE-2023-25184",
          "@source": "NVD"
        },
        {
          "#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
          "@id": "CWE-200",
          "@title": "Information Exposure(CWE-200)"
        },
        {
          "#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
          "@id": "CWE-264",
          "@title": "Permissions(CWE-264)"
        },
        {
          "#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
          "@id": "CWE-287",
          "@title": "Improper Authentication(CWE-287)"
        },
        {
          "#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
          "@id": "CWE-Other",
          "@title": "No Mapping(CWE-Other)"
        }
      ],
      "title": "Multiple vulnerabilities in Seiko Solutions SkyBridge MB-A100/A110/A200/A130 SkySpider MB-R210"
    }

    CVE-2025-54857 (GCVE-0-2025-54857)

    Vulnerability from cvelistv5 – Published: 2025-09-01 05:27 – Updated: 2025-09-02 14:10
    VLAI
    Summary
    Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge BASIC MB-A130 Ver.1.5.8 and earlier. If exploited, a remote unauthenticated attacker may execute arbitrary OS commands with root privileges.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge BASIC MB-A130 Affected: Ver.1.5.8 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-54857",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-02T14:09:54.993899Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-02T14:10:07.142Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.5.8 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in SkyBridge BASIC MB-A130 Ver.1.5.8 and earlier. If exploited, a remote unauthenticated attacker may execute arbitrary OS commands with root privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-01T05:27:10.112Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/90289/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN22016482/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2025-54857",
        "datePublished": "2025-09-01T05:27:10.112Z",
        "dateReserved": "2025-08-25T00:22:42.724Z",
        "dateUpdated": "2025-09-02T14:10:07.142Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32850 (GCVE-0-2024-32850)

    Vulnerability from cvelistv5 – Published: 2024-05-31 01:33 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Improper Neutralization of Special Elements used in a Command ('Command Injection')
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/MB-A110 Affected: firmware Ver. 4.2.2 and earlier
    Create a notification for this product.
    Seiko Solutions Inc. SkyBridge BASIC MB-A130 Affected: firmware Ver. 1.5.5 and earlier
    Create a notification for this product.
    seiko-sol skybridge_basic_mb-a130_firmware Affected: 0 , ≤ 1.5.5 (custom)
        cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    seiko-sol skybridge_mb-a110_firmware Affected: 0 , ≤ 4.2.2 (custom)
        cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_basic_mb-a130_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "1.5.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_mb-a110_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "4.2.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32850",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-31T16:32:25.573045Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-05T20:01:12.070Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:35.662Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/82992/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU94872523/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/MB-A110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.2 and earlier"
                }
              ]
            },
            {
              "product": "SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 1.5.5 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in a command (\u0027Command Injection\u0027) exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-31T01:33:32.849Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/82992/"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94872523/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2024-32850",
        "datePublished": "2024-05-31T01:33:32.849Z",
        "dateReserved": "2024-04-19T05:24:47.944Z",
        "dateUpdated": "2024-08-02T02:20:35.662Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25072 (GCVE-0-2023-25072)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:42
    VLAI
    Summary
    Use of weak credentials exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Use of weak credentials
    • CWE-521 - Weak Password Requirements
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/110 Affected: firmware Ver. 4.2.0 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:11:43.430Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25072",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:41:39.168765Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-521",
                    "description": "CWE-521 Weak Password Requirements",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:42:41.784Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.0 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Use of weak credentials exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of weak credentials",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-25072",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:42:41.784Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-24586 (GCVE-0-2023-24586)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:48
    VLAI
    Summary
    Cleartext storage of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote authenticated attacker to obtain an APN credential for the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Cleartext storage of sensitive information
    • CWE-312 - Cleartext Storage of Sensitive Information
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/110 Affected: firmware Ver. 4.2.0 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:03:18.788Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 3.1,
                  "baseSeverity": "LOW",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-24586",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:48:02.607702Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-312",
                    "description": "CWE-312 Cleartext Storage of Sensitive Information",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:48:12.082Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.0 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cleartext storage of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote authenticated attacker to obtain an APN credential for the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cleartext storage of sensitive information",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-24586",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:48:12.082Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22441 (GCVE-0-2023-22441)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Missing authentication for critical function
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:07:06.550Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.6,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22441",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:51:52.775799Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-306",
                    "description": "CWE-306 Missing Authentication for Critical Function",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:57.223Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Missing authentication for critical function",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-22441",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:57.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23578 (GCVE-0-2023-23578)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 16:52
    VLAI
    Summary
    Improper access control vulnerability in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier allows a remote unauthenticated attacker to connect to the product's ADB port.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Improper access control
    • CWE-346 - Origin Validation Error
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 Affected: firmware Ver. 01.00.05 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:35:33.394Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23578",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T16:52:26.103518Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-346",
                    "description": "CWE-346 Origin Validation Error",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T16:52:34.243Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 01.00.05 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper access control vulnerability in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier allows a remote unauthenticated attacker to connect to the product\u0027s ADB port."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper access control",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23578",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T16:52:34.243Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23906 (GCVE-0-2023-23906)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 16:35
    VLAI
    Summary
    Missing authentication for critical function exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to execute some critical functions without authentication, e.g., rebooting the product.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Missing authentication for critical function
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/110 Affected: firmware Ver. 4.2.0 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:42:27.149Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23906",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T16:35:00.376149Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-306",
                    "description": "CWE-306 Missing Authentication for Critical Function",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T16:35:14.592Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.0 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing authentication for critical function exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to execute some critical functions without authentication, e.g., rebooting the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Missing authentication for critical function",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23906",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T16:35:14.592Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25184 (GCVE-0-2023-25184)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:38
    VLAI
    Summary
    Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Use of weak credentials
    • CWE-521 - Weak Password Requirements
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:18:36.052Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 5.3,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25184",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:38:12.856689Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-521",
                    "description": "CWE-521 Weak Password Requirements",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:38:27.351Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of weak credentials",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-25184",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:38:27.351Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22361 (GCVE-0-2023-22361)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:55
    VLAI
    Summary
    Improper privilege management vulnerability in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier allows a remote authenticated attacker to alter a WebUI password of the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/110 Affected: firmware Ver. 4.2.0 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:07:06.262Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.3,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22361",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:55:27.020494Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "description": "CWE-noinfo Not enough information",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:55:30.333Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.0 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper privilege management vulnerability in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier allows a remote authenticated attacker to alter a WebUI password of the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper privilege management",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-22361",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:55:30.333Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23901 (GCVE-0-2023-23901)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Improper following of a certificate's chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Improper following of a certificate's chain of trust
    • CWE-295 - Improper Certificate Validation
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:42:27.068Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.8,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23901",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:50:59.945196Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-295",
                    "description": "CWE-295 Improper Certificate Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:04.065Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper following of a certificate\u0027s chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper following of a certificate\u0027s chain of trust",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23901",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:04.065Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25070 (GCVE-0-2023-25070)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:46
    VLAI
    Summary
    Cleartext transmission of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier. If the telnet connection is enabled, a remote unauthenticated attacker may eavesdrop on or alter the administrator's communication to the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Cleartext transmission of sensitive information
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/110 Affected: firmware Ver. 4.2.0 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:11:43.918Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.8,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25070",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:44:06.471233Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-319",
                    "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:46:37.940Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.0 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cleartext transmission of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier. If the telnet connection is enabled, a remote unauthenticated attacker may eavesdrop on or alter the administrator\u0027s communication to the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cleartext transmission of sensitive information",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-25070",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:46:37.940Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-54857 (GCVE-0-2025-54857)

    Vulnerability from nvd – Published: 2025-09-01 05:27 – Updated: 2025-09-02 14:10
    VLAI
    Summary
    Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge BASIC MB-A130 Ver.1.5.8 and earlier. If exploited, a remote unauthenticated attacker may execute arbitrary OS commands with root privileges.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge BASIC MB-A130 Affected: Ver.1.5.8 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-54857",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-02T14:09:54.993899Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-02T14:10:07.142Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Ver.1.5.8 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in SkyBridge BASIC MB-A130 Ver.1.5.8 and earlier. If exploited, a remote unauthenticated attacker may execute arbitrary OS commands with root privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-01T05:27:10.112Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/90289/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN22016482/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2025-54857",
        "datePublished": "2025-09-01T05:27:10.112Z",
        "dateReserved": "2025-08-25T00:22:42.724Z",
        "dateUpdated": "2025-09-02T14:10:07.142Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-32850 (GCVE-0-2024-32850)

    Vulnerability from nvd – Published: 2024-05-31 01:33 – Updated: 2024-08-02 02:20
    VLAI
    Summary
    Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Improper Neutralization of Special Elements used in a Command ('Command Injection')
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/MB-A110 Affected: firmware Ver. 4.2.2 and earlier
    Create a notification for this product.
    Seiko Solutions Inc. SkyBridge BASIC MB-A130 Affected: firmware Ver. 1.5.5 and earlier
    Create a notification for this product.
    seiko-sol skybridge_basic_mb-a130_firmware Affected: 0 , ≤ 1.5.5 (custom)
        cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    seiko-sol skybridge_mb-a110_firmware Affected: 0 , ≤ 4.2.2 (custom)
        cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_basic_mb-a130_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_basic_mb-a130_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "1.5.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:seiko-sol:skybridge_mb-a110_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "skybridge_mb-a110_firmware",
                "vendor": "seiko-sol",
                "versions": [
                  {
                    "lessThanOrEqual": "4.2.2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-32850",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-31T16:32:25.573045Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-05T20:01:12.070Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:20:35.662Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/82992/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU94872523/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/MB-A110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.2 and earlier"
                }
              ]
            },
            {
              "product": "SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 1.5.5 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in a command (\u0027Command Injection\u0027) exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-31T01:33:32.849Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/82992/"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU94872523/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2024-32850",
        "datePublished": "2024-05-31T01:33:32.849Z",
        "dateReserved": "2024-04-19T05:24:47.944Z",
        "dateUpdated": "2024-08-02T02:20:35.662Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25184 (GCVE-0-2023-25184)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:38
    VLAI
    Summary
    Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Use of weak credentials
    • CWE-521 - Weak Password Requirements
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:18:36.052Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 5.3,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25184",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:38:12.856689Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-521",
                    "description": "CWE-521 Weak Password Requirements",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:38:27.351Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of weak credentials",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-25184",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:38:27.351Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25072 (GCVE-0-2023-25072)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:42
    VLAI
    Summary
    Use of weak credentials exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Use of weak credentials
    • CWE-521 - Weak Password Requirements
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/110 Affected: firmware Ver. 4.2.0 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:11:43.430Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25072",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:41:39.168765Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-521",
                    "description": "CWE-521 Weak Password Requirements",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:42:41.784Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.0 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Use of weak credentials exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of weak credentials",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-25072",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:42:41.784Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25070 (GCVE-0-2023-25070)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:46
    VLAI
    Summary
    Cleartext transmission of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier. If the telnet connection is enabled, a remote unauthenticated attacker may eavesdrop on or alter the administrator's communication to the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Cleartext transmission of sensitive information
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/110 Affected: firmware Ver. 4.2.0 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:11:43.918Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.8,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25070",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:44:06.471233Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-319",
                    "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:46:37.940Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.0 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cleartext transmission of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier. If the telnet connection is enabled, a remote unauthenticated attacker may eavesdrop on or alter the administrator\u0027s communication to the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cleartext transmission of sensitive information",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-25070",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:46:37.940Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-24586 (GCVE-0-2023-24586)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:48
    VLAI
    Summary
    Cleartext storage of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote authenticated attacker to obtain an APN credential for the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Cleartext storage of sensitive information
    • CWE-312 - Cleartext Storage of Sensitive Information
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/110 Affected: firmware Ver. 4.2.0 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:03:18.788Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 3.1,
                  "baseSeverity": "LOW",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-24586",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:48:02.607702Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-312",
                    "description": "CWE-312 Cleartext Storage of Sensitive Information",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:48:12.082Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.0 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cleartext storage of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote authenticated attacker to obtain an APN credential for the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cleartext storage of sensitive information",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-24586",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:48:12.082Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23906 (GCVE-0-2023-23906)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 16:35
    VLAI
    Summary
    Missing authentication for critical function exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to execute some critical functions without authentication, e.g., rebooting the product.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Missing authentication for critical function
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/110 Affected: firmware Ver. 4.2.0 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:42:27.149Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23906",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T16:35:00.376149Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-306",
                    "description": "CWE-306 Missing Authentication for Critical Function",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T16:35:14.592Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.0 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing authentication for critical function exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to execute some critical functions without authentication, e.g., rebooting the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Missing authentication for critical function",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23906",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T16:35:14.592Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23901 (GCVE-0-2023-23901)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Improper following of a certificate's chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Improper following of a certificate's chain of trust
    • CWE-295 - Improper Certificate Validation
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:42:27.068Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.8,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23901",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:50:59.945196Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-295",
                    "description": "CWE-295 Improper Certificate Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:04.065Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper following of a certificate\u0027s chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper following of a certificate\u0027s chain of trust",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23901",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:04.065Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23578 (GCVE-0-2023-23578)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 16:52
    VLAI
    Summary
    Improper access control vulnerability in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier allows a remote unauthenticated attacker to connect to the product's ADB port.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Improper access control
    • CWE-346 - Origin Validation Error
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 Affected: firmware Ver. 01.00.05 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:35:33.394Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23578",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T16:52:26.103518Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-346",
                    "description": "CWE-346 Origin Validation Error",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T16:52:34.243Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 01.00.05 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper access control vulnerability in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier allows a remote unauthenticated attacker to connect to the product\u0027s ADB port."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper access control",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23578",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T16:52:34.243Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22441 (GCVE-0-2023-22441)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Missing authentication for critical function
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:07:06.550Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.6,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22441",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:51:52.775799Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-306",
                    "description": "CWE-306 Missing Authentication for Critical Function",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:57.223Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Missing authentication for critical function",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-22441",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:57.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22361 (GCVE-0-2023-22361)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:55
    VLAI
    Summary
    Improper privilege management vulnerability in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier allows a remote authenticated attacker to alter a WebUI password of the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A100/110 Affected: firmware Ver. 4.2.0 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:07:06.262Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.3,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22361",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:55:27.020494Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "description": "CWE-noinfo Not enough information",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:55:30.333Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A100/110",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 4.2.0 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper privilege management vulnerability in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier allows a remote authenticated attacker to alter a WebUI password of the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper privilege management",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-22361",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:55:30.333Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }