cve-2024-3313
Vulnerability from cvelistv5
Published
2024-04-09 22:40
Modified
2024-08-01 20:05
Severity ?
8.4 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.6 (High) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.6 (High) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
SUBNET PowerSYSTEM Server and Substation Server Reliance on Insufficiently Trustworthy Component
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:subnet:powersystem_center:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "powersystem_center", "vendor": "subnet", "versions": [ { "lessThan": "4.07.00", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:subnet:substation_server:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "substation_server", "vendor": "subnet", "versions": [ { "lessThan": "4.07.00", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3313", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-12T15:15:28.863506Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-31T18:01:16.170Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:05:08.384Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-100-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerSYSTEM Server", "vendor": "SUBNET Solutions", "versions": [ { "lessThan": "4.07.00", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Substation Server 2021", "vendor": "SUBNET Solutions", "versions": [ { "lessThan": "4.07.00", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "SUBNET Solutions reported these vulnerabilities to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "SUBNET Solutions Inc. has identified vulnerabilities in third-party \ncomponents used in PowerSYSTEM Server 2021 and Substation Server 2021." } ], "value": "SUBNET Solutions Inc. has identified vulnerabilities in third-party \ncomponents used in PowerSYSTEM Server 2021 and Substation Server 2021." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "baseScore": 8.6, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1357", "description": "CWE-1357", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-28T16:54:26.440Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-100-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Subnet Solutions has fixed these issues by identifying and replacing out\n of date libraries used in previous versions of PowerSYSTEM Server and \nSubstation Server 2021. Users are advised to update to version \n4.09.00.927 or newer. To obtain this software, contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://subnet.com/contact/\"\u003eSubnet Solution\u0027s Customer Service.\u003c/a\u003e\n\n\u003cbr\u003e" } ], "value": "Subnet Solutions has fixed these issues by identifying and replacing out\n of date libraries used in previous versions of PowerSYSTEM Server and \nSubstation Server 2021. Users are advised to update to version \n4.09.00.927 or newer. To obtain this software, contact Subnet Solution\u0027s Customer Service. https://subnet.com/contact/" } ], "source": { "advisory": "ICSA-24-100-01", "discovery": "INTERNAL" }, "title": "SUBNET PowerSYSTEM Server and Substation Server Reliance on Insufficiently Trustworthy Component", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2024-3313", "datePublished": "2024-04-09T22:40:26.692Z", "dateReserved": "2024-04-04T15:57:57.596Z", "dateUpdated": "2024-08-01T20:05:08.384Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-3313\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2024-04-09T23:15:25.423\",\"lastModified\":\"2024-05-28T17:15:11.210\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"SUBNET Solutions Inc. has identified vulnerabilities in third-party \\ncomponents used in PowerSYSTEM Server 2021 and Substation Server 2021.\"},{\"lang\":\"es\",\"value\":\"SUBNET Solutions Inc. ha identificado vulnerabilidades en componentes de terceros utilizados en PowerSYSTEM Server 2021 y Substation Server 2021.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.5,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1357\"}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-24-100-01\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.