cve-2024-34086
Vulnerability from cvelistv5
Published
2024-05-14 10:03
Modified
2024-08-02 02:42
Severity
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "jt2go",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "V2312.0001",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "V14.1.0.13",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "14.2.0.10",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "V2312.0001",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "teamcenter_visualization",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "14.3.0.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-34086",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T15:19:05.198442Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-06T18:22:25.821Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:42:59.863Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0001",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.1.0.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.2.0.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0001",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file.\r\nThis could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:24:55.854Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-34086",
    "datePublished": "2024-05-14T10:03:10.774Z",
    "dateReserved": "2024-04-30T09:05:07.900Z",
    "dateUpdated": "2024-08-02T02:42:59.863Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-34086\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-05-14T16:17:23.290\",\"lastModified\":\"2024-05-14T19:17:55.627\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file.\\r\\nThis could allow an attacker to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones \u0026lt; V2312.0001), Teamcenter Visualization V14.1 (Todas las versiones \u0026lt; V14.1.0.13), Teamcenter Visualization V14.2 (Todas las versiones \u0026lt; V14.2.0.10), Teamcenter Visualization V14.3 (Todas las versiones \u0026lt; V14.3.0.7), Teamcenter Visualization V2312 (Todas las versiones \u0026lt; V2312.0001). Las aplicaciones afectadas contienen una vulnerabilidad de escritura fuera de los l\u00edmites al analizar un archivo CGM especialmente manipulado. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-661579.html\",\"source\":\"productcert@siemens.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...