Summary
Rockwell Automation FactoryTalk® Remote Access™ has Unquoted Executables
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Rockwell Automation | FactoryTalk® Remote Access™ |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-3640", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-16T17:57:33.825467Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:31:28.680Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:20:00.578Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1671.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FactoryTalk\u00ae Remote Access\u2122", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v13.5.0.174" } ] } ], "datePublic": "2024-05-16T15:14:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn unquoted executable path exists in the Rockwell Automation\u0026nbsp;FactoryTalk\u00ae Remote Access\u2122 possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a System user. A threat actor needs admin privileges to exploit this vulnerability. \u003c/span\u003e\n\n" } ], "value": "An unquoted executable path exists in the Rockwell Automation\u00a0FactoryTalk\u00ae Remote Access\u2122 possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a System user. A threat actor needs admin privileges to exploit this vulnerability." } ], "impacts": [ { "capecId": "CAPEC-38", "descriptions": [ { "lang": "en", "value": "CAPEC-38 Leveraging/Manipulating Configuration File Search Paths" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "baseScore": 7, "baseSeverity": "HIGH", "privilegesRequired": "HIGH", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "ACTIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428 Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-16T15:25:28.558Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1671.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cul\u003e\u003cli\u003eCorrected in v13.6.\u003c/li\u003e\u003c/ul\u003e" } ], "value": "* Corrected in v13.6." }, { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003eUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices below, where possible. \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e" } ], "value": "Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices below, where possible. \n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight" } ], "source": { "discovery": "INTERNAL" }, "title": "Rockwell Automation FactoryTalk\u00ae Remote Access\u2122 has Unquoted Executables", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2024-3640", "datePublished": "2024-05-16T15:25:28.558Z", "dateReserved": "2024-04-10T20:45:50.623Z", "dateUpdated": "2024-08-01T20:20:00.578Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-3640\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-05-16T16:15:10.477\",\"lastModified\":\"2024-05-17T18:36:31.297\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"An unquoted executable path exists in the Rockwell Automation\u00a0FactoryTalk\u00ae Remote Access\u2122 possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a System user. A threat actor needs admin privileges to exploit this vulnerability.\"},{\"lang\":\"es\",\"value\":\"Existe una ruta ejecutable sin comillas en Rockwell Automation FactoryTalk\u00ae Remote Access\u2122 que, si se explota, podr\u00eda provocar la ejecuci\u00f3n remota de c\u00f3digo. Mientras se ejecuta el paquete de instalaci\u00f3n de FTRA, la ruta del ejecutable no se cita correctamente, lo que podr\u00eda permitir que un actor de amenazas ingrese un ejecutable malicioso y lo ejecute como usuario del sistema. Un actor malicioso necesita privilegios de administrador para explotar esta vulnerabilidad.\"}],\"metrics\":{},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-428\"}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/support/advisory.SD1671.html\",\"source\":\"PSIRT@rockwellautomation.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.