cve-2024-3904
Vulnerability from cvelistv5
Published
2024-07-04 09:11
Modified
2024-08-01 20:26
Summary
Incorrect Default Permissions vulnerability in Smart Device Communication Gateway preinstalled on MELIPC Series MI5122-VW firmware versions "05" to "07" allows a local attacker to execute arbitrary code by saving a malicious file to a specific folder. As a result, the attacker may disclose, tamper with, destroy or delete information in the product, or cause a denial-of-service (DoS) condition on the product.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:mitsubishi:melipc_mi5122-vw_firmware:05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "melipc_mi5122-vw_firmware",
            "vendor": "mitsubishi",
            "versions": [
              {
                "lessThanOrEqual": "07",
                "status": "affected",
                "version": "05",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-3904",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-05T13:49:41.501811Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T13:52:40.732Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:26:57.118Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-003_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU91215350/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MELIPC Series MI5122-VW",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware versions \"05\" to \"07\""
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Incorrect Default Permissions vulnerability in Smart Device Communication Gateway preinstalled on MELIPC Series MI5122-VW firmware versions \"05\" to \"07\" allows a local attacker to execute arbitrary code by saving a malicious file to a specific folder. As a result, the attacker may disclose, tamper with, destroy or delete information in the product, or cause a denial-of-service (DoS) condition on the product."
            }
          ],
          "value": "Incorrect Default Permissions vulnerability in Smart Device Communication Gateway preinstalled on MELIPC Series MI5122-VW firmware versions \"05\" to \"07\" allows a local attacker to execute arbitrary code by saving a malicious file to a specific folder. As a result, the attacker may disclose, tamper with, destroy or delete information in the product, or cause a denial-of-service (DoS) condition on the product."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Malicious Code Execution"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276 Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-23T00:28:13.328Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-003_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU91215350/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-02"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2024-3904",
    "datePublished": "2024-07-04T09:11:22.679Z",
    "dateReserved": "2024-04-17T02:56:01.539Z",
    "dateUpdated": "2024-08-01T20:26:57.118Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-3904\",\"sourceIdentifier\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"published\":\"2024-07-04T09:15:04.317\",\"lastModified\":\"2024-07-23T01:15:09.063\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Incorrect Default Permissions vulnerability in Smart Device Communication Gateway preinstalled on MELIPC Series MI5122-VW firmware versions \\\"05\\\" to \\\"07\\\" allows a local attacker to execute arbitrary code by saving a malicious file to a specific folder. As a result, the attacker may disclose, tamper with, destroy or delete information in the product, or cause a denial-of-service (DoS) condition on the product.\"},{\"lang\":\"es\",\"value\":\"La vulnerabilidad de permisos predeterminados incorrectos en Smart Device Communication Gateway preinstalado en las versiones de firmware \\\"05\\\" a \\\"07\\\" de la serie MI5122-VW de MELIPC permite a un atacante local ejecutar c\u00f3digo arbitrario guardando un archivo malicioso en una carpeta espec\u00edfica. Como resultado, el atacante puede revelar, alterar, destruir o eliminar informaci\u00f3n del producto, o provocar una condici\u00f3n de denegaci\u00f3n de servicio (DoS) en el producto.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.0,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-276\"}]}],\"references\":[{\"url\":\"https://jvn.jp/vu/JVNVU91215350/index.html\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\"},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-02\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\"},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-003_en.pdf\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.