CVE-2024-40893 (GCVE-0-2024-40893)
Vulnerability from cvelistv5 – Published: 2024-08-12 18:49 – Updated: 2024-08-21 17:13
VLAI?
Title
Firewalla BTLE Authenticated Command Injection
Summary
Multiple authenticated operating system (OS) command injection vulnerabilities exist in Firewalla Box Software
versions before 1.979. A physically close
attacker that is authenticated to the Bluetooth Low-Energy (BTLE) interface can use the network configuration service to inject commands in various configuration parameters including networkConfig.Interface.Phy.Eth0.Extra.PingTestIP, networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain, and networkConfig.Interface.Phy.Eth0.Gateway6. Additionally, because the configuration can be synced to the Firewalla cloud, the attacker may be able to persist access even after hardware resets and firmware re-flashes.
Severity ?
6.8 (Medium)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Firewalla | Box Software |
Affected:
0 , < 1.979
(custom)
|
Credits
Matthew "Remy" Remacle of GreyNoise
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:firewalla:box_software:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "box_software",
"vendor": "firewalla",
"versions": [
{
"lessThan": "1.979",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-40893",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-14T13:25:43.056042Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-14T13:26:40.904Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Box Software",
"vendor": "Firewalla",
"versions": [
{
"lessThan": "1.979",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Matthew \"Remy\" Remacle of GreyNoise"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Multiple authenticated operating system (OS) command injection vulnerabilities exist in Firewalla Box Software \nversions before 1.979. A physically close \nattacker that is authenticated to the Bluetooth Low-Energy (BTLE) interface can use the network configuration service to inject commands in various configuration parameters including\u0026nbsp;networkConfig.Interface.Phy.Eth0.Extra.PingTestIP,\u0026nbsp;networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain, and\u0026nbsp;networkConfig.Interface.Phy.Eth0.Gateway6. Additionally, because the configuration can be synced to the Firewalla cloud, the attacker may be able to persist access even after hardware resets and firmware re-flashes. \u003cbr\u003e"
}
],
"value": "Multiple authenticated operating system (OS) command injection vulnerabilities exist in Firewalla Box Software \nversions before 1.979. A physically close \nattacker that is authenticated to the Bluetooth Low-Energy (BTLE) interface can use the network configuration service to inject commands in various configuration parameters including\u00a0networkConfig.Interface.Phy.Eth0.Extra.PingTestIP,\u00a0networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain, and\u00a0networkConfig.Interface.Phy.Eth0.Gateway6. Additionally, because the configuration can be synced to the Firewalla cloud, the attacker may be able to persist access even after hardware resets and firmware re-flashes."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T17:13:39.202Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/firewalla-bt-command-injection"
},
{
"tags": [
"technical-description",
"exploit"
],
"url": "https://www.labs.greynoise.io/grimoire/2024-08-20-bluuid-firewalla/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2024-04-12T03:46:00.000Z",
"value": "Contact initiated with Firewalla"
},
{
"lang": "en",
"time": "2024-04-12T19:04:00.000Z",
"value": "Issues disclosed"
},
{
"lang": "en",
"time": "2024-07-24T04:00:00.000Z",
"value": "Firewalla Box version 1.979 released to early access"
},
{
"lang": "en",
"time": "2024-08-12T17:30:00.000Z",
"value": "Third-Party advisory published"
}
],
"title": "Firewalla BTLE Authenticated Command Injection",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-40893",
"datePublished": "2024-08-12T18:49:51.384Z",
"dateReserved": "2024-07-11T17:35:29.595Z",
"dateUpdated": "2024-08-21T17:13:39.202Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"Multiple authenticated operating system (OS) command injection vulnerabilities exist in Firewalla Box Software \\nversions before 1.979. A physically close \\nattacker that is authenticated to the Bluetooth Low-Energy (BTLE) interface can use the network configuration service to inject commands in various configuration parameters including\\u00a0networkConfig.Interface.Phy.Eth0.Extra.PingTestIP,\\u00a0networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain, and\\u00a0networkConfig.Interface.Phy.Eth0.Gateway6. Additionally, because the configuration can be synced to the Firewalla cloud, the attacker may be able to persist access even after hardware resets and firmware re-flashes.\"}, {\"lang\": \"es\", \"value\": \"Existen m\\u00faltiples vulnerabilidades de inyecci\\u00f3n de comandos del sistema operativo (SO) autenticado en las versiones del software Firewalla Box anteriores a la 1.979. Un atacante f\\u00edsicamente cercano que est\\u00e9 autenticado en la interfaz Bluetooth Low-Energy (BTLE) puede usar el servicio de configuraci\\u00f3n de red para inyectar comandos en varios par\\u00e1metros de configuraci\\u00f3n, incluidos networkConfig.Interface.Phy.Eth0.Extra.PingTestIP, networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain y networkConfig.Interface.Phy.Eth0.Gateway6. Adem\\u00e1s, debido a que la configuraci\\u00f3n se puede sincronizar con la nube de Firewalla, el atacante puede persistir en el acceso incluso despu\\u00e9s de reiniciar el hardware y actualizar el firmware.\"}]",
"id": "CVE-2024-40893",
"lastModified": "2024-08-21T18:15:09.803",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"disclosure@vulncheck.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.9, \"impactScore\": 5.9}]}",
"published": "2024-08-12T19:15:16.643",
"references": "[{\"url\": \"https://vulncheck.com/advisories/firewalla-bt-command-injection\", \"source\": \"disclosure@vulncheck.com\"}, {\"url\": \"https://www.labs.greynoise.io/grimoire/2024-08-20-bluuid-firewalla/\", \"source\": \"disclosure@vulncheck.com\"}]",
"sourceIdentifier": "disclosure@vulncheck.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"disclosure@vulncheck.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-40893\",\"sourceIdentifier\":\"disclosure@vulncheck.com\",\"published\":\"2024-08-12T19:15:16.643\",\"lastModified\":\"2024-08-21T18:15:09.803\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Multiple authenticated operating system (OS) command injection vulnerabilities exist in Firewalla Box Software \\nversions before 1.979. A physically close \\nattacker that is authenticated to the Bluetooth Low-Energy (BTLE) interface can use the network configuration service to inject commands in various configuration parameters including\u00a0networkConfig.Interface.Phy.Eth0.Extra.PingTestIP,\u00a0networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain, and\u00a0networkConfig.Interface.Phy.Eth0.Gateway6. Additionally, because the configuration can be synced to the Firewalla cloud, the attacker may be able to persist access even after hardware resets and firmware re-flashes.\"},{\"lang\":\"es\",\"value\":\"Existen m\u00faltiples vulnerabilidades de inyecci\u00f3n de comandos del sistema operativo (SO) autenticado en las versiones del software Firewalla Box anteriores a la 1.979. Un atacante f\u00edsicamente cercano que est\u00e9 autenticado en la interfaz Bluetooth Low-Energy (BTLE) puede usar el servicio de configuraci\u00f3n de red para inyectar comandos en varios par\u00e1metros de configuraci\u00f3n, incluidos networkConfig.Interface.Phy.Eth0.Extra.PingTestIP, networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain y networkConfig.Interface.Phy.Eth0.Gateway6. Adem\u00e1s, debido a que la configuraci\u00f3n se puede sincronizar con la nube de Firewalla, el atacante puede persistir en el acceso incluso despu\u00e9s de reiniciar el hardware y actualizar el firmware.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://vulncheck.com/advisories/firewalla-bt-command-injection\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://www.labs.greynoise.io/grimoire/2024-08-20-bluuid-firewalla/\",\"source\":\"disclosure@vulncheck.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-40893\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-14T13:25:43.056042Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:firewalla:box_software:*:*:*:*:*:*:*:*\"], \"vendor\": \"firewalla\", \"product\": \"box_software\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.979\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-14T13:26:33.771Z\"}}], \"cna\": {\"title\": \"Firewalla BTLE Authenticated Command Injection\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Matthew \\\"Remy\\\" Remacle of GreyNoise\"}], \"impacts\": [{\"capecId\": \"CAPEC-88\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-88 OS Command Injection\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.8, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Firewalla\", \"product\": \"Box Software\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.979\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2024-04-12T03:46:00.000Z\", \"value\": \"Contact initiated with Firewalla\"}, {\"lang\": \"en\", \"time\": \"2024-04-12T19:04:00.000Z\", \"value\": \"Issues disclosed\"}, {\"lang\": \"en\", \"time\": \"2024-07-24T04:00:00.000Z\", \"value\": \"Firewalla Box version 1.979 released to early access\"}, {\"lang\": \"en\", \"time\": \"2024-08-12T17:30:00.000Z\", \"value\": \"Third-Party advisory published\"}], \"references\": [{\"url\": \"https://vulncheck.com/advisories/firewalla-bt-command-injection\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://www.labs.greynoise.io/grimoire/2024-08-20-bluuid-firewalla/\", \"tags\": [\"technical-description\", \"exploit\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Multiple authenticated operating system (OS) command injection vulnerabilities exist in Firewalla Box Software \\nversions before 1.979. A physically close \\nattacker that is authenticated to the Bluetooth Low-Energy (BTLE) interface can use the network configuration service to inject commands in various configuration parameters including\\u00a0networkConfig.Interface.Phy.Eth0.Extra.PingTestIP,\\u00a0networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain, and\\u00a0networkConfig.Interface.Phy.Eth0.Gateway6. Additionally, because the configuration can be synced to the Firewalla cloud, the attacker may be able to persist access even after hardware resets and firmware re-flashes.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Multiple authenticated operating system (OS) command injection vulnerabilities exist in Firewalla Box Software \\nversions before 1.979. A physically close \\nattacker that is authenticated to the Bluetooth Low-Energy (BTLE) interface can use the network configuration service to inject commands in various configuration parameters including\u0026nbsp;networkConfig.Interface.Phy.Eth0.Extra.PingTestIP,\u0026nbsp;networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain, and\u0026nbsp;networkConfig.Interface.Phy.Eth0.Gateway6. Additionally, because the configuration can be synced to the Firewalla cloud, the attacker may be able to persist access even after hardware resets and firmware re-flashes. \u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"shortName\": \"VulnCheck\", \"dateUpdated\": \"2024-08-21T17:13:39.202Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-40893\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-21T17:13:39.202Z\", \"dateReserved\": \"2024-07-11T17:35:29.595Z\", \"assignerOrgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"datePublished\": \"2024-08-12T18:49:51.384Z\", \"assignerShortName\": \"VulnCheck\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…