CVE-2024-41752 (GCVE-0-2024-41752)

Vulnerability from cvelistv5 – Published: 2024-12-18 16:07 – Updated: 2024-12-18 19:37
VLAI?
Summary
IBM Cognos Analytics 11.2.0 through 11.2.4 and 12.0.0 through 12.0.3 is vulnerable to HTML injection. A remote attacker could inject malicious HTML code, which when viewed, would be executed in the victim's Web browser within the security context of the hosting site.
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
ibm
References
Impacted products
Vendor Product Version
IBM Cognos Analytics Affected: 11.2.0 , ≤ 11.2.4 (semver)
Affected: 12.0.0 , ≤ 12.0.3 (semver)
    cpe:2.3:a:ibm:cognos_analytics:11.2.0:*:*:*:*:*:*:*
    cpe:2.3:a:ibm:cognos_analytics:11.2.1:*:*:*:*:*:*:*
    cpe:2.3:a:ibm:cognos_analytics:11.2.2:*:*:*:*:*:*:*
    cpe:2.3:a:ibm:cognos_analytics:11.2.3:*:*:*:*:*:*:*
    cpe:2.3:a:ibm:cognos_analytics:11.2.4:*:*:*:*:*:*:*
    cpe:2.3:a:ibm:cognos_analytics:12.0.0:*:*:*:*:*:*:*
    cpe:2.3:a:ibm:cognos_analytics:12.0.1:*:*:*:*:*:*:*
    cpe:2.3:a:ibm:cognos_analytics:12.0.2:*:*:*:*:*:*:*
    cpe:2.3:a:ibm:cognos_analytics:12.0.3:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-41752",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-18T19:36:51.734065Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-18T19:37:04.686Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:ibm:cognos_analytics:11.2.0:*:*:*:*:*:*:*",
            "cpe:2.3:a:ibm:cognos_analytics:11.2.1:*:*:*:*:*:*:*",
            "cpe:2.3:a:ibm:cognos_analytics:11.2.2:*:*:*:*:*:*:*",
            "cpe:2.3:a:ibm:cognos_analytics:11.2.3:*:*:*:*:*:*:*",
            "cpe:2.3:a:ibm:cognos_analytics:11.2.4:*:*:*:*:*:*:*",
            "cpe:2.3:a:ibm:cognos_analytics:12.0.0:*:*:*:*:*:*:*",
            "cpe:2.3:a:ibm:cognos_analytics:12.0.1:*:*:*:*:*:*:*",
            "cpe:2.3:a:ibm:cognos_analytics:12.0.2:*:*:*:*:*:*:*",
            "cpe:2.3:a:ibm:cognos_analytics:12.0.3:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Cognos Analytics",
          "vendor": "IBM",
          "versions": [
            {
              "lessThanOrEqual": "11.2.4",
              "status": "affected",
              "version": "11.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "12.0.3",
              "status": "affected",
              "version": "12.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIBM Cognos Analytics\u003c/span\u003e\u0026nbsp;11.2.0 through 11.2.4 and 12.0.0 through 12.0.3 is vulnerable to HTML injection. A remote attacker could inject malicious HTML code, which when viewed, would be executed in the victim\u0027s Web browser within the security context of the hosting site.\u003c/span\u003e"
            }
          ],
          "value": "IBM Cognos Analytics\u00a011.2.0 through 11.2.4 and 12.0.0 through 12.0.3 is vulnerable to HTML injection. A remote attacker could inject malicious HTML code, which when viewed, would be executed in the victim\u0027s Web browser within the security context of the hosting site."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-18T16:07:14.012Z",
        "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "shortName": "ibm"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.ibm.com/support/pages/node/7177223"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "IBM Cognos Analytics HTML injection",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
    "assignerShortName": "ibm",
    "cveId": "CVE-2024-41752",
    "datePublished": "2024-12-18T16:07:14.012Z",
    "dateReserved": "2024-07-22T12:02:37.814Z",
    "dateUpdated": "2024-12-18T19:37:04.686Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:cognos_analytics:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"11.2.0\", \"versionEndIncluding\": \"11.2.4\", \"matchCriteriaId\": \"792D3191-C65E-41C3-834D-45F162020756\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:cognos_analytics:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"12.0.0\", \"versionEndIncluding\": \"12.0.3\", \"matchCriteriaId\": \"5C1AE531-B015-421A-84A2-2F0C9E50312D\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"IBM Cognos Analytics\\u00a011.2.0 through 11.2.4 and 12.0.0 through 12.0.3 is vulnerable to HTML injection. A remote attacker could inject malicious HTML code, which when viewed, would be executed in the victim\u0027s Web browser within the security context of the hosting site.\"}, {\"lang\": \"es\", \"value\": \"IBM Cognos Analytics 11.2.0 a 11.2.4 y 12.0.0 a 12.0.3 es vulnerable a la inyecci\\u00f3n de c\\u00f3digo HTML. Un atacante remoto podr\\u00eda inyectar c\\u00f3digo HTML malicioso que, al visualizarse, se ejecutar\\u00eda en el navegador web de la v\\u00edctima dentro del contexto de seguridad del sitio de alojamiento.\"}]",
      "id": "CVE-2024-41752",
      "lastModified": "2025-01-10T19:33:46.213",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"psirt@us.ibm.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N\", \"baseScore\": 5.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 2.7}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 2.7}]}",
      "published": "2024-12-18T17:15:13.223",
      "references": "[{\"url\": \"https://www.ibm.com/support/pages/node/7177223\", \"source\": \"psirt@us.ibm.com\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "psirt@us.ibm.com",
      "vulnStatus": "Analyzed",
      "weaknesses": "[{\"source\": \"psirt@us.ibm.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-80\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-41752\",\"sourceIdentifier\":\"psirt@us.ibm.com\",\"published\":\"2024-12-18T17:15:13.223\",\"lastModified\":\"2025-01-10T19:33:46.213\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"IBM Cognos Analytics\u00a011.2.0 through 11.2.4 and 12.0.0 through 12.0.3 is vulnerable to HTML injection. A remote attacker could inject malicious HTML code, which when viewed, would be executed in the victim\u0027s Web browser within the security context of the hosting site.\"},{\"lang\":\"es\",\"value\":\"IBM Cognos Analytics 11.2.0 a 11.2.4 y 12.0.0 a 12.0.3 es vulnerable a la inyecci\u00f3n de c\u00f3digo HTML. Un atacante remoto podr\u00eda inyectar c\u00f3digo HTML malicioso que, al visualizarse, se ejecutar\u00eda en el navegador web de la v\u00edctima dentro del contexto de seguridad del sitio de alojamiento.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@us.ibm.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"psirt@us.ibm.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-80\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:cognos_analytics:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.2.0\",\"versionEndIncluding\":\"11.2.4\",\"matchCriteriaId\":\"792D3191-C65E-41C3-834D-45F162020756\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:cognos_analytics:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.0\",\"versionEndIncluding\":\"12.0.3\",\"matchCriteriaId\":\"5C1AE531-B015-421A-84A2-2F0C9E50312D\"}]}]}],\"references\":[{\"url\":\"https://www.ibm.com/support/pages/node/7177223\",\"source\":\"psirt@us.ibm.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-41752\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-12-18T19:36:51.734065Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-12-18T19:37:00.210Z\"}}], \"cna\": {\"title\": \"IBM Cognos Analytics HTML injection\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 5.4, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:ibm:cognos_analytics:11.2.0:*:*:*:*:*:*:*\", \"cpe:2.3:a:ibm:cognos_analytics:11.2.1:*:*:*:*:*:*:*\", \"cpe:2.3:a:ibm:cognos_analytics:11.2.2:*:*:*:*:*:*:*\", \"cpe:2.3:a:ibm:cognos_analytics:11.2.3:*:*:*:*:*:*:*\", \"cpe:2.3:a:ibm:cognos_analytics:11.2.4:*:*:*:*:*:*:*\", \"cpe:2.3:a:ibm:cognos_analytics:12.0.0:*:*:*:*:*:*:*\", \"cpe:2.3:a:ibm:cognos_analytics:12.0.1:*:*:*:*:*:*:*\", \"cpe:2.3:a:ibm:cognos_analytics:12.0.2:*:*:*:*:*:*:*\", \"cpe:2.3:a:ibm:cognos_analytics:12.0.3:*:*:*:*:*:*:*\"], \"vendor\": \"IBM\", \"product\": \"Cognos Analytics\", \"versions\": [{\"status\": \"affected\", \"version\": \"11.2.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"11.2.4\"}, {\"status\": \"affected\", \"version\": \"12.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"12.0.3\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.ibm.com/support/pages/node/7177223\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"IBM Cognos Analytics\\u00a011.2.0 through 11.2.4 and 12.0.0 through 12.0.3 is vulnerable to HTML injection. A remote attacker could inject malicious HTML code, which when viewed, would be executed in the victim\u0027s Web browser within the security context of the hosting site.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eIBM Cognos Analytics\u003c/span\u003e\u0026nbsp;11.2.0 through 11.2.4 and 12.0.0 through 12.0.3 is vulnerable to HTML injection. A remote attacker could inject malicious HTML code, which when viewed, would be executed in the victim\u0027s Web browser within the security context of the hosting site.\u003c/span\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-80\", \"description\": \"CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)\"}]}], \"providerMetadata\": {\"orgId\": \"9a959283-ebb5-44b6-b705-dcc2bbced522\", \"shortName\": \"ibm\", \"dateUpdated\": \"2024-12-18T16:07:14.012Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-41752\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-12-18T19:37:04.686Z\", \"dateReserved\": \"2024-07-22T12:02:37.814Z\", \"assignerOrgId\": \"9a959283-ebb5-44b6-b705-dcc2bbced522\", \"datePublished\": \"2024-12-18T16:07:14.012Z\", \"assignerShortName\": \"ibm\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…