A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 SP2). The affected application inserts sensitive information into a log file which is readable by all legitimate users of the underlying system. This could allow an authenticated attacker to compromise the confidentiality of other users' configuration data.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-417159.html | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | SINEMA Remote Connect Client |
Version: 0 < V3.2 SP2 |
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-42344", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T14:54:03.621110Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T14:54:10.749Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SINEMA Remote Connect Client", "vendor": "Siemens", "versions": [ { "lessThan": "V3.2 SP2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Client (All versions \u003c V3.2 SP2). The affected application inserts sensitive information into a log file which is readable by all legitimate users of the underlying system. This could allow an authenticated attacker to compromise the confidentiality of other users\u0027 configuration data." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 4.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-532", "description": "CWE-532: Insertion of Sensitive Information into Log File", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:47.430Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-417159.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-42344", "datePublished": "2024-09-10T09:36:47.430Z", "dateReserved": "2024-07-30T11:53:04.709Z", "dateUpdated": "2024-09-10T14:54:10.749Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-42344\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-09-10T10:15:12.213\",\"lastModified\":\"2024-09-10T18:54:58.413\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEMA Remote Connect Client (All versions \u003c V3.2 SP2). The affected application inserts sensitive information into a log file which is readable by all legitimate users of the underlying system. This could allow an authenticated attacker to compromise the confidentiality of other users\u0027 configuration data.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEMA Remote Connect Client (todas las versiones anteriores a V3.2 SP2). La aplicaci\u00f3n afectada inserta informaci\u00f3n confidencial en un archivo de registro que pueden leer todos los usuarios leg\u00edtimos del sistema subyacente. Esto podr\u00eda permitir que un atacante autenticado comprometa la confidencialidad de los datos de configuraci\u00f3n de otros usuarios.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"LOW\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"NONE\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\"}}],\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:L\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.8,\"impactScore\":2.5}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_client:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.2\",\"matchCriteriaId\":\"7DA05EE4-6C59-4FA4-BCA5-B7A246E11E48\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_client:3.2:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"FF91D6EE-AE6E-4B31-89E2-72848EB2273A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_client:3.2:hf1:*:*:*:*:*:*\",\"matchCriteriaId\":\"15171F96-9402-4C39-8001-E5FDFBD7CA48\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_client:3.2:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"ACAE5FD9-8F0A-4045-8A0A-96AA5966D05E\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-417159.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.