CVE-2024-50359 (GCVE-0-2024-50359)
Vulnerability from cvelistv5 – Published: 2024-11-26 10:53 – Updated: 2024-11-26 14:19
VLAI?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "scan_ap" API which are not properly sanitized before being concatenated to OS level commands.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Advantech | EKI-6333AC-2G |
Affected:
0 , ≤ <= 1.6.3
(semver)
|
||||||||||||
|
||||||||||||||
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2g_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-2gd_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "eki-6333ac-1gpo_firmware",
"vendor": "advantech",
"versions": [
{
"lessThanOrEqual": "1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-50359",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T14:12:07.036649Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T14:19:27.111Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2G",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-2GD",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.6.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EKI-6333AC-1GPO",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "\u003c= 1.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"scan_ap\" API which are not properly sanitized before being concatenated to OS level commands.\u003cbr\u003e"
}
],
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"scan_ap\" API which are not properly sanitized before being concatenated to OS level commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T11:24:44.812Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50359"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
}
],
"value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-50359",
"datePublished": "2024-11-26T10:53:20.791Z",
"dateReserved": "2024-10-23T07:55:56.655Z",
"dateUpdated": "2024-11-26T14:19:27.111Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-78 \\\"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\\\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \\\"scan_ap\\\" API which are not properly sanitized before being concatenated to OS level commands.\"}, {\"lang\": \"es\", \"value\": \"Se descubri\\u00f3 una vulnerabilidad CWE-78 \\\"Neutralizaci\\u00f3n incorrecta de elementos especiales utilizados en un comando del sistema operativo (\u0027Inyecci\\u00f3n de comando del sistema operativo\u0027)\\\" que afectaba a los siguientes dispositivos fabricados por Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) y EKI-6333AC-1GPO (\u0026lt;= v1.2.1). La fuente de la vulnerabilidad se basa en m\\u00faltiples par\\u00e1metros pertenecientes a la API \\\"scan_ap\\\" que no se desinfectan correctamente antes de concatenarse con comandos de nivel del sistema operativo.\"}]",
"id": "CVE-2024-50359",
"lastModified": "2024-11-26T11:22:00.460",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"prodsec@nozominetworks.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}]}",
"published": "2024-11-26T11:22:00.460",
"references": "[{\"url\": \"https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50359\", \"source\": \"prodsec@nozominetworks.com\"}]",
"sourceIdentifier": "prodsec@nozominetworks.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"prodsec@nozominetworks.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-50359\",\"sourceIdentifier\":\"prodsec@nozominetworks.com\",\"published\":\"2024-11-26T11:22:00.460\",\"lastModified\":\"2024-11-26T11:22:00.460\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-78 \\\"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\\\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \\\"scan_ap\\\" API which are not properly sanitized before being concatenated to OS level commands.\"},{\"lang\":\"es\",\"value\":\"Se descubri\u00f3 una vulnerabilidad CWE-78 \\\"Neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando del sistema operativo (\u0027Inyecci\u00f3n de comando del sistema operativo\u0027)\\\" que afectaba a los siguientes dispositivos fabricados por Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) y EKI-6333AC-1GPO (\u0026lt;= v1.2.1). La fuente de la vulnerabilidad se basa en m\u00faltiples par\u00e1metros pertenecientes a la API \\\"scan_ap\\\" que no se desinfectan correctamente antes de concatenarse con comandos de nivel del sistema operativo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"prodsec@nozominetworks.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"prodsec@nozominetworks.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50359\",\"source\":\"prodsec@nozominetworks.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-50359\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-26T14:12:07.036649Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"advantech\", \"product\": \"eki-6333ac-2g_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.6.3\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"advantech\", \"product\": \"eki-6333ac-2gd_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.6.3\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"advantech\", \"product\": \"eki-6333ac-1gpo_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.2.1\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-26T14:10:41.611Z\"}}], \"cna\": {\"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Advantech\", \"product\": \"EKI-6333AC-2G\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"\u003c= 1.6.3\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Advantech\", \"product\": \"EKI-6333AC-2GD\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"\u003c= 1.6.3\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Advantech\", \"product\": \"EKI-6333AC-1GPO\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"\u003c= 1.2.1\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Update affected products to the following firmware versions released by Advantech:\\n- EKI-6333AC-2G: v1.6.5\\n- EKI-6333AC-2GD: v1.6.5\\n- EKI-6333AC-1GPO: v1.2.2\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50359\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A CWE-78 \\\"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\\\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \\\"scan_ap\\\" API which are not properly sanitized before being concatenated to OS level commands.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A CWE-78 \\\"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\\\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \\\"scan_ap\\\" API which are not properly sanitized before being concatenated to OS level commands.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"bec8025f-a851-46e5-b3a3-058e6b0aa23c\", \"shortName\": \"Nozomi\", \"dateUpdated\": \"2024-11-26T11:24:44.812Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-50359\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-26T14:19:27.111Z\", \"dateReserved\": \"2024-10-23T07:55:56.655Z\", \"assignerOrgId\": \"bec8025f-a851-46e5-b3a3-058e6b0aa23c\", \"datePublished\": \"2024-11-26T10:53:20.791Z\", \"assignerShortName\": \"Nozomi\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…