CVE-2024-51072 (GCVE-0-2024-51072)

Vulnerability from cvelistv5 – Published: 2024-11-22 00:00 – Updated: 2025-01-10 14:21 Disputed
VLAI
Summary
An issue in KIA Seltos vehicle instrument cluster with software and hardware v1.0 allows attackers to cause a Denial of Service (DoS) via ECU reset UDS service. NOTE: this is disputed by the Supplier because the findings came from a potentially unrealistic test environment (an isolated ECU part that was not in a vehicle), and because the ECUReset specification does not allow a manufacturer to require SecurityAccess and Authentication.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-26 17:22 UTC
CWE
  • n/a
  • CWE-346 - Origin Validation Error
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "HIGH",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-51072",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-26T17:22:02.819208Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-346",
                "description": "CWE-346 Origin Validation Error",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-26T17:22:06.455Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in KIA Seltos vehicle instrument cluster with software and hardware v1.0 allows attackers to cause a Denial of Service (DoS) via ECU reset UDS service. NOTE: this is disputed by the Supplier because the findings came from a potentially unrealistic test environment (an isolated ECU part that was not in a vehicle), and because the ECUReset specification does not allow a manufacturer to require SecurityAccess and Authentication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-10T14:21:13.205Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.iso.org/standard/77323.html"
        },
        {
          "url": "https://udsoncan.readthedocs.io/en/latest/udsoncan/services.html"
        },
        {
          "url": "https://github.com/nitinronge91/KIA-SELTOS-Cluster-Vulnerabilities/blob/628b1550f0093f79380929074b6a5e6ca6f2d04b/CVE/Denial%20of%20Service%20via%20ECU%20Reset%20Service%20For%20KIA%20SELTOS%20CVE-2024-51072.md"
        }
      ],
      "tags": [
        "disputed"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-51072",
    "datePublished": "2024-11-22T00:00:00.000Z",
    "dateReserved": "2024-10-28T00:00:00.000Z",
    "dateUpdated": "2025-01-10T14:21:13.205Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-51072",
      "date": "2026-09-22",
      "epss": "0.00212",
      "percentile": "0.1185"
    },
    "fkie_nvd": {
      "cveTags": [
        {
          "sourceIdentifier": "cve@mitre.org",
          "tags": [
            "disputed"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in KIA Seltos vehicle instrument cluster with software and hardware v1.0 allows attackers to cause a Denial of Service (DoS) via ECU reset UDS service. NOTE: this is disputed by the Supplier because the findings came from a potentially unrealistic test environment (an isolated ECU part that was not in a vehicle), and because the ECUReset specification does not allow a manufacturer to require SecurityAccess and Authentication."
        },
        {
          "lang": "es",
          "value": "Un problema en Instrument Cluster KIA Seltos Software v1.0, Hardware v1.0 permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS)."
        }
      ],
      "id": "CVE-2024-51072",
      "lastModified": "2025-01-10T15:15:15.173",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "HIGH",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 0.9,
            "impactScore": 4.0,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      },
      "published": "2024-11-22T16:15:33.603",
      "references": [
        {
          "source": "cve@mitre.org",
          "url": "https://github.com/nitinronge91/KIA-SELTOS-Cluster-Vulnerabilities/blob/628b1550f0093f79380929074b6a5e6ca6f2d04b/CVE/Denial%20of%20Service%20via%20ECU%20Reset%20Service%20For%20KIA%20SELTOS%20CVE-2024-51072.md"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://udsoncan.readthedocs.io/en/latest/udsoncan/services.html"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://www.iso.org/standard/77323.html"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-346"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "n/a",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "n/a"
                  }
                ]
              }
            ],
            "source": "cve@mitre.org"
          }
        ],
        "cveTags": [
          {
            "sourceIdentifier": "cve@mitre.org",
            "tags": [
              "disputed"
            ]
          }
        ],
        "descriptions": [
          {
            "lang": "en",
            "value": "An issue in KIA Seltos vehicle instrument cluster with software and hardware v1.0 allows attackers to cause a Denial of Service (DoS) via ECU reset UDS service. NOTE: this is disputed by the Supplier because the findings came from a potentially unrealistic test environment (an isolated ECU part that was not in a vehicle), and because the ECUReset specification does not allow a manufacturer to require SecurityAccess and Authentication."
          },
          {
            "lang": "es",
            "value": "Un problema en Instrument Cluster KIA Seltos Software v1.0, Hardware v1.0 permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS)."
          }
        ],
        "id": "CVE-2024-51072",
        "lastModified": "2026-06-17T08:05:22.263",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 0.9,
              "impactScore": 4.0,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-51072",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-26T17:22:02.819208Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-11-22T16:15:33.603",
        "references": [
          {
            "source": "cve@mitre.org",
            "url": "https://github.com/nitinronge91/KIA-SELTOS-Cluster-Vulnerabilities/blob/628b1550f0093f79380929074b6a5e6ca6f2d04b/CVE/Denial%20of%20Service%20via%20ECU%20Reset%20Service%20For%20KIA%20SELTOS%20CVE-2024-51072.md"
          },
          {
            "source": "cve@mitre.org",
            "url": "https://udsoncan.readthedocs.io/en/latest/udsoncan/services.html"
          },
          {
            "source": "cve@mitre.org",
            "url": "https://www.iso.org/standard/77323.html"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-346"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T09:37:30+00:00",
      "cve": "CVE-2024-51072",
      "id": "CVE-2024-51072",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2024-51072",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-51072.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "PHYSICAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 5.3,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "CHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-51072",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-26T17:22:02.819208Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-346",
                    "description": "CWE-346 Origin Validation Error",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-26T17:18:05.693Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in KIA Seltos vehicle instrument cluster with software and hardware v1.0 allows attackers to cause a Denial of Service (DoS) via ECU reset UDS service. NOTE: this is disputed by the Supplier because the findings came from a potentially unrealistic test environment (an isolated ECU part that was not in a vehicle), and because the ECUReset specification does not allow a manufacturer to require SecurityAccess and Authentication."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-10T14:21:13.205Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.iso.org/standard/77323.html"
            },
            {
              "url": "https://udsoncan.readthedocs.io/en/latest/udsoncan/services.html"
            },
            {
              "url": "https://github.com/nitinronge91/KIA-SELTOS-Cluster-Vulnerabilities/blob/628b1550f0093f79380929074b6a5e6ca6f2d04b/CVE/Denial%20of%20Service%20via%20ECU%20Reset%20Service%20For%20KIA%20SELTOS%20CVE-2024-51072.md"
            }
          ],
          "tags": [
            "disputed"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-51072",
        "datePublished": "2024-11-22T00:00:00.000Z",
        "dateReserved": "2024-10-28T00:00:00.000Z",
        "dateUpdated": "2025-01-10T14:21:13.205Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…