cve-2024-56334
Vulnerability from cvelistv5
Published
2024-12-20 20:10
Modified
2024-12-20 20:10
Severity ?
EPSS score ?
Summary
systeminformation is a System and OS information library for node.js. In affected versions SSIDs are not sanitized when before they are passed as a parameter to cmd.exe in the `getWindowsIEEE8021x` function. This means that malicious content in the SSID can be executed as OS commands. This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation. This issue has been addressed in version 5.23.7 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | sebhildebrandt | systeminformation |
Version: < 5.23.7 |
|
{ "containers": { "cna": { "affected": [ { "product": "systeminformation", "vendor": "sebhildebrandt", "versions": [ { "status": "affected", "version": "\u003c 5.23.7" } ] } ], "descriptions": [ { "lang": "en", "value": "systeminformation is a System and OS information library for node.js. In affected versions SSIDs are not sanitized when before they are passed as a parameter to cmd.exe in the `getWindowsIEEE8021x` function. This means that malicious content in the SSID can be executed as OS commands. This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation. This issue has been addressed in version 5.23.7 and all users are advised to upgrade. There are no known workarounds for this vulnerability." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-20T20:10:12.578Z", "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa", "shortName": "GitHub_M" }, "references": [ { "name": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m", "tags": [ "x_refsource_CONFIRM" ], "url": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m" }, { "name": "https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41", "tags": [ "x_refsource_MISC" ], "url": "https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41" } ], "source": { "advisory": "GHSA-cvv5-9h9w-qp2m", "discovery": "UNKNOWN" }, "title": "Command injection vulnerability in getWindowsIEEE8021x (SSID) function in systeminformation" } }, "cveMetadata": { "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa", "assignerShortName": "GitHub_M", "cveId": "CVE-2024-56334", "datePublished": "2024-12-20T20:10:12.578Z", "dateReserved": "2024-12-19T18:39:53.612Z", "dateUpdated": "2024-12-20T20:10:12.578Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-56334\",\"sourceIdentifier\":\"security-advisories@github.com\",\"published\":\"2024-12-20T21:15:10.080\",\"lastModified\":\"2024-12-20T21:15:10.080\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"systeminformation is a System and OS information library for node.js. In affected versions SSIDs are not sanitized when before they are passed as a parameter to cmd.exe in the `getWindowsIEEE8021x` function. This means that malicious content in the SSID can be executed as OS commands. This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation. This issue has been addressed in version 5.23.7 and all users are advised to upgrade. There are no known workarounds for this vulnerability.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security-advisories@github.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"security-advisories@github.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]}],\"references\":[{\"url\":\"https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41\",\"source\":\"security-advisories@github.com\"},{\"url\":\"https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m\",\"source\":\"security-advisories@github.com\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.