CVE-2024-6147 (GCVE-0-2024-6147)
Vulnerability from cvelistv5 – Published: 2024-06-20 20:11 – Updated: 2024-08-01 21:33
VLAI?
Summary
Poly Plantronics Hub Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Poly Plantronics Hub. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.
The specific flaw exists within the Spokes Update Service. By creating a symbolic link, an attacker can abuse the service to delete a file. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-18271.
Severity ?
7.8 (High)
CWE
- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Poly | Plantronics Hub |
Affected:
3.24.2 Build 36336
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:plantronics:plantronics_hub:*:*:*:*:*:windows:*:*"
],
"defaultStatus": "unknown",
"product": "plantronics_hub",
"vendor": "plantronics",
"versions": [
{
"status": "affected",
"version": "3.24.2 Build 36336"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6147",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-25T19:21:00.721267Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-26T19:40:03.741Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:33:04.947Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-24-802",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-802/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Plantronics Hub",
"vendor": "Poly",
"versions": [
{
"status": "affected",
"version": "3.24.2 Build 36336"
}
]
}
],
"dateAssigned": "2024-06-18T16:11:49.104-05:00",
"datePublic": "2024-06-18T18:32:18.515-05:00",
"descriptions": [
{
"lang": "en",
"value": "Poly Plantronics Hub Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Poly Plantronics Hub. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the Spokes Update Service. By creating a symbolic link, an attacker can abuse the service to delete a file. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-18271."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-20T20:11:52.626Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-802",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-802/"
}
],
"source": {
"lang": "en",
"value": "Michael DePlante (@izobashi) of Trend Micro\u0027s Zero Day Initiative"
},
"title": "Poly Plantronics Hub Link Following Local Privilege Escalation Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2024-6147",
"datePublished": "2024-06-20T20:11:52.626Z",
"dateReserved": "2024-06-18T21:11:49.077Z",
"dateUpdated": "2024-08-01T21:33:04.947Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:poly_plantronics_hub:3.24.2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4FA6BE6E-41A3-42E8-B80F-4519FE5955E4\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Poly Plantronics Hub Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Poly Plantronics Hub. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.\\n\\nThe specific flaw exists within the Spokes Update Service. By creating a symbolic link, an attacker can abuse the service to delete a file. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-18271.\"}, {\"lang\": \"es\", \"value\": \"Vulnerabilidad de escalada de privilegios local en Poly Plantronics Hub Link Following. Esta vulnerabilidad permite a atacantes locales escalar privilegios en las instalaciones afectadas de Poly Plantronics Hub. Un atacante primero debe obtener la capacidad de ejecutar c\\u00f3digo con pocos privilegios en el sistema de destino para poder explotar esta vulnerabilidad. La falla espec\\u00edfica existe dentro del Servicio de Actualizaci\\u00f3n de Spokes. Al crear un enlace simb\\u00f3lico, un atacante puede abusar del servicio para eliminar un archivo. Un atacante puede aprovechar esta vulnerabilidad para escalar privilegios y ejecutar c\\u00f3digo arbitrario en el contexto de SYSTEM. Era ZDI-CAN-18271.\"}]",
"id": "CVE-2024-6147",
"lastModified": "2024-11-21T09:49:03.910",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV30\": [{\"source\": \"zdi-disclosures@trendmicro.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}]}",
"published": "2024-06-20T20:15:20.707",
"references": "[{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-24-802/\", \"source\": \"zdi-disclosures@trendmicro.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-24-802/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}]",
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"zdi-disclosures@trendmicro.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-59\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-59\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-6147\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2024-06-20T20:15:20.707\",\"lastModified\":\"2024-11-21T09:49:03.910\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Poly Plantronics Hub Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Poly Plantronics Hub. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.\\n\\nThe specific flaw exists within the Spokes Update Service. By creating a symbolic link, an attacker can abuse the service to delete a file. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-18271.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de escalada de privilegios local en Poly Plantronics Hub Link Following. Esta vulnerabilidad permite a atacantes locales escalar privilegios en las instalaciones afectadas de Poly Plantronics Hub. Un atacante primero debe obtener la capacidad de ejecutar c\u00f3digo con pocos privilegios en el sistema de destino para poder explotar esta vulnerabilidad. La falla espec\u00edfica existe dentro del Servicio de Actualizaci\u00f3n de Spokes. Al crear un enlace simb\u00f3lico, un atacante puede abusar del servicio para eliminar un archivo. Un atacante puede aprovechar esta vulnerabilidad para escalar privilegios y ejecutar c\u00f3digo arbitrario en el contexto de SYSTEM. Era ZDI-CAN-18271.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-59\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-59\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:poly_plantronics_hub:3.24.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FA6BE6E-41A3-42E8-B80F-4519FE5955E4\"}]}]}],\"references\":[{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-24-802/\",\"source\":\"zdi-disclosures@trendmicro.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-24-802/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-24-802/\", \"name\": \"ZDI-24-802\", \"tags\": [\"x_research-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T21:33:04.947Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-6147\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-06-25T19:21:00.721267Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:plantronics:plantronics_hub:*:*:*:*:*:windows:*:*\"], \"vendor\": \"plantronics\", \"product\": \"plantronics_hub\", \"versions\": [{\"status\": \"affected\", \"version\": \"3.24.2 Build 36336\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-06-26T19:39:58.994Z\"}}], \"cna\": {\"title\": \"Poly Plantronics Hub Link Following Local Privilege Escalation Vulnerability\", \"source\": {\"lang\": \"en\", \"value\": \"Michael DePlante (@izobashi) of Trend Micro\u0027s Zero Day Initiative\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}], \"affected\": [{\"vendor\": \"Poly\", \"product\": \"Plantronics Hub\", \"versions\": [{\"status\": \"affected\", \"version\": \"3.24.2 Build 36336\"}], \"defaultStatus\": \"unknown\"}], \"datePublic\": \"2024-06-18T18:32:18.515-05:00\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-24-802/\", \"name\": \"ZDI-24-802\", \"tags\": [\"x_research-advisory\"]}], \"dateAssigned\": \"2024-06-18T16:11:49.104-05:00\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"Poly Plantronics Hub Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Poly Plantronics Hub. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.\\n\\nThe specific flaw exists within the Spokes Update Service. By creating a symbolic link, an attacker can abuse the service to delete a file. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-18271.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-59\", \"description\": \"CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"shortName\": \"zdi\", \"dateUpdated\": \"2024-06-20T20:11:52.626Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-6147\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T21:33:04.947Z\", \"dateReserved\": \"2024-06-18T21:11:49.077Z\", \"assignerOrgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"datePublished\": \"2024-06-20T20:11:52.626Z\", \"assignerShortName\": \"zdi\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…