CVE-2024-6814 (GCVE-0-2024-6814)
Vulnerability from cvelistv5 – Published: 2024-08-21 16:09 – Updated: 2024-08-21 17:54
VLAI?
Title
NETGEAR ProSAFE Network Management System getFilterString SQL Injection Remote Code Execution Vulnerability
Summary
NETGEAR ProSAFE Network Management System getFilterString SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Authentication is required to exploit this vulnerability.
The specific flaw exists within the getFilterString method. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-23399.
Severity ?
8.8 (High)
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| NETGEAR | ProSAFE Network Management System |
Affected:
1.7.0.34 x64
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:netgear:nms300_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nms300_firmware",
"vendor": "netgear",
"versions": [
{
"lessThan": "1.7.0.37",
"status": "affected",
"version": "1.7.0.34_x64",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6814",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-21T17:50:57.790542Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T17:54:08.616Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "ProSAFE Network Management System",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "1.7.0.34 x64"
}
]
}
],
"dateAssigned": "2024-07-16T16:14:46.879-05:00",
"datePublic": "2024-07-18T13:20:02.177-05:00",
"descriptions": [
{
"lang": "en",
"value": "NETGEAR ProSAFE Network Management System getFilterString SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the getFilterString method. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-23399."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T16:09:11.108Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-901",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-901/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://kb.netgear.com/000066232/Security-Advisory-for-SQL-Injection-on-the-NMS300-PSV-2024-0019"
}
],
"source": {
"lang": "en",
"value": "Piotr Bazydlo (@chudypb) of Trend Micro Zero Day Initiative"
},
"title": "NETGEAR ProSAFE Network Management System getFilterString SQL Injection Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2024-6814",
"datePublished": "2024-08-21T16:09:11.108Z",
"dateReserved": "2024-07-16T21:14:46.853Z",
"dateUpdated": "2024-08-21T17:54:08.616Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:netgear:prosafe_network_management_system:1.7.0.34:*:*:*:*:*:x64:*\", \"matchCriteriaId\": \"BDEC02AC-2E65-4E3E-9A27-C77CFE3D6494\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"NETGEAR ProSAFE Network Management System getFilterString SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Authentication is required to exploit this vulnerability.\\n\\nThe specific flaw exists within the getFilterString method. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-23399.\"}, {\"lang\": \"es\", \"value\": \"Vulnerabilidad de ejecuci\\u00f3n remota de c\\u00f3digo de inyecci\\u00f3n SQL NETGEAR ProSAFE Network Management System getFilterString. Esta vulnerabilidad permite a atacantes remotos ejecutar c\\u00f3digo arbitrario en instalaciones afectadas de NETGEAR ProSAFE Network Management System. Se requiere autenticaci\\u00f3n para aprovechar esta vulnerabilidad. La falla espec\\u00edfica existe dentro del m\\u00e9todo getFilterString. El problema se debe a la falta de validaci\\u00f3n adecuada de una cadena proporcionada por el usuario antes de usarla para construir consultas SQL. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\\u00f3digo en el contexto de SYSTEM. Era ZDI-CAN-23399.\"}]",
"id": "CVE-2024-6814",
"lastModified": "2024-08-27T15:03:09.817",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV30\": [{\"source\": \"zdi-disclosures@trendmicro.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}]}",
"published": "2024-08-21T16:15:09.357",
"references": "[{\"url\": \"https://kb.netgear.com/000066232/Security-Advisory-for-SQL-Injection-on-the-NMS300-PSV-2024-0019\", \"source\": \"zdi-disclosures@trendmicro.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-24-901/\", \"source\": \"zdi-disclosures@trendmicro.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}]",
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": "[{\"source\": \"zdi-disclosures@trendmicro.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-89\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-6814\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2024-08-21T16:15:09.357\",\"lastModified\":\"2024-08-27T15:03:09.817\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"NETGEAR ProSAFE Network Management System getFilterString SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Authentication is required to exploit this vulnerability.\\n\\nThe specific flaw exists within the getFilterString method. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-23399.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo de inyecci\u00f3n SQL NETGEAR ProSAFE Network Management System getFilterString. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en instalaciones afectadas de NETGEAR ProSAFE Network Management System. Se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. La falla espec\u00edfica existe dentro del m\u00e9todo getFilterString. El problema se debe a la falta de validaci\u00f3n adecuada de una cadena proporcionada por el usuario antes de usarla para construir consultas SQL. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto de SYSTEM. Era ZDI-CAN-23399.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:netgear:prosafe_network_management_system:1.7.0.34:*:*:*:*:*:x64:*\",\"matchCriteriaId\":\"BDEC02AC-2E65-4E3E-9A27-C77CFE3D6494\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000066232/Security-Advisory-for-SQL-Injection-on-the-NMS300-PSV-2024-0019\",\"source\":\"zdi-disclosures@trendmicro.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-24-901/\",\"source\":\"zdi-disclosures@trendmicro.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-6814\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-21T17:50:57.790542Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:netgear:nms300_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"netgear\", \"product\": \"nms300_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.7.0.34_x64\", \"lessThan\": \"1.7.0.37\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-21T17:53:49.381Z\"}}], \"cna\": {\"title\": \"NETGEAR ProSAFE Network Management System getFilterString SQL Injection Remote Code Execution Vulnerability\", \"source\": {\"lang\": \"en\", \"value\": \"Piotr Bazydlo (@chudypb) of Trend Micro Zero Day Initiative\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}], \"affected\": [{\"vendor\": \"NETGEAR\", \"product\": \"ProSAFE Network Management System\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.7.0.34 x64\"}], \"defaultStatus\": \"unknown\"}], \"datePublic\": \"2024-07-18T13:20:02.177-05:00\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-24-901/\", \"name\": \"ZDI-24-901\", \"tags\": [\"x_research-advisory\"]}, {\"url\": \"https://kb.netgear.com/000066232/Security-Advisory-for-SQL-Injection-on-the-NMS300-PSV-2024-0019\", \"name\": \"vendor-provided URL\", \"tags\": [\"vendor-advisory\"]}], \"dateAssigned\": \"2024-07-16T16:14:46.879-05:00\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"NETGEAR ProSAFE Network Management System getFilterString SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Authentication is required to exploit this vulnerability.\\n\\nThe specific flaw exists within the getFilterString method. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-23399.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-89\", \"description\": \"CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"shortName\": \"zdi\", \"dateUpdated\": \"2024-08-21T16:09:11.108Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-6814\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-21T17:54:08.616Z\", \"dateReserved\": \"2024-07-16T21:14:46.853Z\", \"assignerOrgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"datePublished\": \"2024-08-21T16:09:11.108Z\", \"assignerShortName\": \"zdi\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…