CVE-2025-0037 (GCVE-0-2025-0037)

Vulnerability from cvelistv5 – Published: 2025-06-09 23:52 – Updated: 2025-06-10 15:27
VLAI?
Summary
In AMD Versal Adaptive SoC devices, the lack of address validation when executing PLM runtime services through the PLM firmware can allow access to isolated or protected memory spaces, resulting in the loss of integrity and confidentiality.
CWE
  • CWE-20 - Improper Input Validation
Assigner
AMD
Impacted products
Vendor Product Version
AMD Platform Loader and Manager (PLM) Affected: Refer to AMD-SB-8010 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-0037",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-10T14:19:54.367326Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-10T15:27:52.107Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Platform Loader and Manager (PLM)",
          "vendor": "AMD",
          "versions": [
            {
              "status": "affected",
              "version": "Refer to AMD-SB-8010",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2025-06-03T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In AMD Versal Adaptive SoC devices, the lack of address validation when executing PLM runtime services through the PLM firmware can allow access to isolated or protected memory spaces, resulting in the loss of integrity and confidentiality.\u003cbr\u003e"
            }
          ],
          "value": "In AMD Versal Adaptive SoC devices, the lack of address validation when executing PLM runtime services through the PLM firmware can allow access to isolated or protected memory spaces, resulting in the loss of integrity and confidentiality."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-09T23:52:33.688Z",
        "orgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
        "shortName": "AMD"
      },
      "references": [
        {
          "url": "https://www.amd.com/en/resources/product-security/bulletin/amd-sb-8010.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
    "assignerShortName": "AMD",
    "cveId": "CVE-2025-0037",
    "datePublished": "2025-06-09T23:52:33.688Z",
    "dateReserved": "2024-11-21T16:18:04.172Z",
    "dateUpdated": "2025-06-10T15:27:52.107Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-0037\",\"sourceIdentifier\":\"psirt@amd.com\",\"published\":\"2025-06-10T00:15:22.103\",\"lastModified\":\"2025-06-12T16:06:39.330\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In AMD Versal Adaptive SoC devices, the lack of address validation when executing PLM runtime services through the PLM firmware can allow access to isolated or protected memory spaces, resulting in the loss of integrity and confidentiality.\"},{\"lang\":\"es\",\"value\":\"En los dispositivos SoC AMD Versal Adaptive, la falta de validaci\u00f3n de direcciones al ejecutar servicios de tiempo de ejecuci\u00f3n PLM a trav\u00e9s del firmware PLM puede permitir el acceso a espacios de memoria aislados o protegidos, lo que resulta en la p\u00e9rdida de integridad y confidencialidad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@amd.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H\",\"baseScore\":6.6,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":4.7}]},\"weaknesses\":[{\"source\":\"psirt@amd.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"references\":[{\"url\":\"https://www.amd.com/en/resources/product-security/bulletin/amd-sb-8010.html\",\"source\":\"psirt@amd.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-0037\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-10T14:19:54.367326Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-10T14:19:56.093Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.6, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"AMD\", \"product\": \"Platform Loader and Manager (PLM)\", \"versions\": [{\"status\": \"affected\", \"version\": \"Refer to AMD-SB-8010\", \"versionType\": \"custom\"}], \"defaultStatus\": \"affected\"}], \"datePublic\": \"2025-06-03T16:00:00.000Z\", \"references\": [{\"url\": \"https://www.amd.com/en/resources/product-security/bulletin/amd-sb-8010.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"In AMD Versal Adaptive SoC devices, the lack of address validation when executing PLM runtime services through the PLM firmware can allow access to isolated or protected memory spaces, resulting in the loss of integrity and confidentiality.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"In AMD Versal Adaptive SoC devices, the lack of address validation when executing PLM runtime services through the PLM firmware can allow access to isolated or protected memory spaces, resulting in the loss of integrity and confidentiality.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20 Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"b58fc414-a1e4-4f92-9d70-1add41838648\", \"shortName\": \"AMD\", \"dateUpdated\": \"2025-06-09T23:52:33.688Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-0037\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-10T15:27:52.107Z\", \"dateReserved\": \"2024-11-21T16:18:04.172Z\", \"assignerOrgId\": \"b58fc414-a1e4-4f92-9d70-1add41838648\", \"datePublished\": \"2025-06-09T23:52:33.688Z\", \"assignerShortName\": \"AMD\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…