CVE-2025-10150 (GCVE-0-2025-10150)
Vulnerability from cvelistv5 – Published: 2025-10-28 07:24 – Updated: 2025-10-28 13:28
VLAI?
Title
Webserver crash caused by scanning on TCP port 80
Summary
Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects
smartLink HW-PN: from 1.02 through 1.03
smartLink HW-DP: 1.31
Severity ?
CWE
- CWE-833 - Deadlock
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Softing Industrial Automation GmbH | smartLink HW-PN |
Affected:
1.02 , ≤ 1.03
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10150",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-28T13:27:44.147539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T13:28:01.850Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "smartLink HW-PN",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.03",
"status": "affected",
"version": "1.02",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "smartLink HW-DP",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.31",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-pn:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.03",
"versionStartIncluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-dp:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.31",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects\n\nsmartLink HW-PN: from 1.02 through 1.03\n\nsmartLink HW-DP: 1.31"
}
],
"impacts": [
{
"capecId": "CAPEC-25",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-25 Forced Deadlock"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-833",
"description": "CWE-833: Deadlock",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T07:24:38.296Z",
"orgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"shortName": "Softing"
},
"references": [
{
"tags": [
"x_html"
],
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.html"
},
{
"tags": [
"x_json"
],
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "This issue is fixed in\n\nsmartLink HW-PN: 1.04\n\nsmartLink HW-DP: 1.32"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Webserver crash caused by scanning on TCP port 80",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"assignerShortName": "Softing",
"cveId": "CVE-2025-10150",
"datePublished": "2025-10-28T07:24:38.296Z",
"dateReserved": "2025-09-09T07:27:03.262Z",
"dateUpdated": "2025-10-28T13:28:01.850Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-10150\",\"sourceIdentifier\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\",\"published\":\"2025-10-28T08:15:32.600\",\"lastModified\":\"2025-10-30T15:05:32.197\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects\\n\\nsmartLink HW-PN: from 1.02 through 1.03\\n\\nsmartLink HW-DP: 1.31\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:X/RE:M/U:Amber\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"LOW\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"YES\",\"Recovery\":\"USER\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"MODERATE\",\"providerUrgency\":\"AMBER\"}}]},\"weaknesses\":[{\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-833\"}]}],\"references\":[{\"url\":\"https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.html\",\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\"},{\"url\":\"https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.json\",\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-10150\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-10-28T13:27:44.147539Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-10-28T13:27:56.136Z\"}}], \"cna\": {\"title\": \"Webserver crash caused by scanning on TCP port 80\", \"source\": {\"discovery\": \"INTERNAL\"}, \"impacts\": [{\"capecId\": \"CAPEC-25\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-25 Forced Deadlock\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"USER\", \"baseScore\": 8.7, \"Automatable\": \"YES\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Amber\", \"providerUrgency\": \"AMBER\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"LOW\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"MODERATE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Softing Industrial Automation GmbH\", \"product\": \"smartLink HW-PN\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.02\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.03\"}], \"defaultStatus\": \"affected\"}, {\"vendor\": \"Softing Industrial Automation GmbH\", \"product\": \"smartLink HW-DP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.31\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"This issue is fixed in\\n\\nsmartLink HW-PN: 1.04\\n\\nsmartLink HW-DP: 1.32\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003cbr\u003e\u003c/p\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.html\", \"tags\": [\"x_html\"]}, {\"url\": \"https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.json\", \"tags\": [\"x_json\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects\\n\\nsmartLink HW-PN: from 1.02 through 1.03\\n\\nsmartLink HW-DP: 1.31\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003cbr\u003e\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-833\", \"description\": \"CWE-833: Deadlock\"}]}], \"cpeApplicability\": [{\"nodes\": [{\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-pn:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"1.03\", \"versionStartIncluding\": \"1.02\"}], \"operator\": \"OR\"}, {\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-dp:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"1.31\", \"versionStartIncluding\": \"0\"}], \"operator\": \"OR\"}], \"operator\": \"OR\"}], \"providerMetadata\": {\"orgId\": \"10de8ef9-5c89-4b17-8228-e97b74acf4bd\", \"shortName\": \"Softing\", \"dateUpdated\": \"2025-10-28T07:24:38.296Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-10150\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-28T13:28:01.850Z\", \"dateReserved\": \"2025-09-09T07:27:03.262Z\", \"assignerOrgId\": \"10de8ef9-5c89-4b17-8228-e97b74acf4bd\", \"datePublished\": \"2025-10-28T07:24:38.296Z\", \"assignerShortName\": \"Softing\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…