CVE-2025-11779 (GCVE-0-2025-11779)

Vulnerability from cvelistv5 – Published: 2025-12-02 12:57 – Updated: 2025-12-02 13:44
VLAI?
Summary
Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The 'SetLan' function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the 'index.cgi' web application. The parameters are not being sanitised, which could lead to command injection.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Credits
Gabriel Gonzalez and Sergio Ruiz
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11779",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-02T13:44:18.885863Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-02T13:44:57.270Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Circutor",
          "vendor": "SGE-PLC1000 SGE-PLC50",
          "versions": [
            {
              "status": "affected",
              "version": "9.0.2"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Gabriel Gonzalez and Sergio Ruiz"
        }
      ],
      "datePublic": "2025-10-28T11:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027SetLan\u0027 function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the \u0027index.cgi\u0027 web application. The parameters are not being sanitised, which could lead to command injection."
            }
          ],
          "value": "Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027SetLan\u0027 function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the \u0027index.cgi\u0027 web application. The parameters are not being sanitised, which could lead to command injection."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-02T12:57:46.050Z",
        "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "shortName": "INCIBE"
      },
      "references": [
        {
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "tags": [
        "unsupported-when-assigned"
      ],
      "title": "Stack-based buffer overflow vulnreability in Circutor SGE-PLC1000/SGE-PLC50",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
    "assignerShortName": "INCIBE",
    "cveId": "CVE-2025-11779",
    "datePublished": "2025-12-02T12:57:46.050Z",
    "dateReserved": "2025-10-15T12:06:08.399Z",
    "dateUpdated": "2025-12-02T13:44:57.270Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-11779\",\"sourceIdentifier\":\"cve-coordination@incibe.es\",\"published\":\"2025-12-02T13:15:48.583\",\"lastModified\":\"2025-12-03T19:07:24.863\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[{\"sourceIdentifier\":\"cve-coordination@incibe.es\",\"tags\":[\"unsupported-when-assigned\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027SetLan\u0027 function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the \u0027index.cgi\u0027 web application. The parameters are not being sanitised, which could lead to command injection.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cve-coordination@incibe.es\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":9.4,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"ADJACENT\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"HIGH\",\"subIntegrityImpact\":\"HIGH\",\"subAvailabilityImpact\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cve-coordination@incibe.es\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FFF41215-1018-42DD-9A7E-BBC2E5B4522D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"203C8B5E-582A-4680-B324-B9092F01462B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"447D1571-5329-422D-8E31-F4964E412FC3\"}]}]}],\"references\":[{\"url\":\"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0\",\"source\":\"cve-coordination@incibe.es\",\"tags\":[\"Third Party Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-11779\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-12-02T13:44:18.885863Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-12-02T13:44:51.410Z\"}}], \"cna\": {\"tags\": [\"unsupported-when-assigned\"], \"title\": \"Stack-based buffer overflow vulnreability in Circutor SGE-PLC1000/SGE-PLC50\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Gabriel Gonzalez and Sergio Ruiz\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 9.4, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"SGE-PLC1000 SGE-PLC50\", \"product\": \"Circutor\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.0.2\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API.\", \"base64\": false}]}], \"datePublic\": \"2025-10-28T11:00:00.000Z\", \"references\": [{\"url\": \"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.5.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027SetLan\u0027 function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the \u0027index.cgi\u0027 web application. The parameters are not being sanitised, which could lead to command injection.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027SetLan\u0027 function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the \u0027index.cgi\u0027 web application. The parameters are not being sanitised, which could lead to command injection.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121: Stack-based Buffer Overflow\"}]}], \"cpeApplicability\": [{\"nodes\": [{\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*\", \"vulnerable\": true}], \"operator\": \"OR\"}], \"operator\": \"OR\"}], \"providerMetadata\": {\"orgId\": \"0cbda920-cd7f-484a-8e76-bf7f4b7f4516\", \"shortName\": \"INCIBE\", \"dateUpdated\": \"2025-12-02T12:57:46.050Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-11779\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-12-02T13:44:57.270Z\", \"dateReserved\": \"2025-10-15T12:06:08.399Z\", \"assignerOrgId\": \"0cbda920-cd7f-484a-8e76-bf7f4b7f4516\", \"datePublished\": \"2025-12-02T12:57:46.050Z\", \"assignerShortName\": \"INCIBE\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…