CVE-2025-12994 (GCVE-0-2025-12994)
Vulnerability from cvelistv5 – Published: 2025-12-04 20:02 – Updated: 2025-12-04 20:02
VLAI?
Summary
Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025.
Severity ?
5.3 (Medium)
CWE
- CWE-204 - Observable Response Discrepancy
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Medtronic | CareLink Network |
Affected:
0 , < December 4, 2025
(custom)
|
Credits
Bernhard Lorenz
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CareLink Network",
"vendor": "Medtronic",
"versions": [
{
"lessThan": "December 4, 2025",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bernhard Lorenz"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025."
}
],
"value": "Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025."
}
],
"impacts": [
{
"capecId": "CAPEC-575",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-575: Account Footprinting"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-204",
"description": "CWE-204 Observable Response Discrepancy",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-04T20:02:06.492Z",
"orgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
"shortName": "Medtronic"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.medtronic.com/en-us/e/product-security/security-bulletins/carelink-network-vulnerabilities.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
"assignerShortName": "Medtronic",
"cveId": "CVE-2025-12994",
"datePublished": "2025-12-04T20:02:06.492Z",
"dateReserved": "2025-11-11T03:38:43.879Z",
"dateUpdated": "2025-12-04T20:02:06.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-12994\",\"sourceIdentifier\":\"security@medtronic.com\",\"published\":\"2025-12-04T20:16:17.037\",\"lastModified\":\"2025-12-04T20:16:17.037\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security@medtronic.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"security@medtronic.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-204\"}]}],\"references\":[{\"url\":\"https://www.medtronic.com/en-us/e/product-security/security-bulletins/carelink-network-vulnerabilities.html\",\"source\":\"security@medtronic.com\"}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…